BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

179 related articles for article (PubMed ID: 20847066)

  • 1. Combination technique of tumescent anesthesia during endovenous laser therapy of saphenous vein insufficiency.
    Memetoglu ME; Kurtcan S; Kalkan A; Özel D
    Interact Cardiovasc Thorac Surg; 2010 Dec; 11(6):774-7. PubMed ID: 20847066
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of pain during endovenous laser ablation of the great saphenous vein with ultrasound-guided femoral nerve block.
    Al Wahbi AM
    Vasc Health Risk Manag; 2017; 13():305-309. PubMed ID: 28860790
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Is the temperature of tumescent anesthesia applied in the endovenous laser ablation important? comparison of different temperatures for tumescent anesthesia applied during endovenous ablation of incompetent great saphenous vein with a 1470 nm diode laser.
    Abud B; Karaarslan K; Turhan S; Karaman Y
    Vascular; 2014 Dec; 22(6):421-6. PubMed ID: 24459131
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of ultrasound-guided femoral nerve block in endoluminal laser ablation of the greater saphenous vein.
    Dzieciuchowicz L; Espinosa G; Grochowicz L
    Ann Vasc Surg; 2010 Oct; 24(7):930-4. PubMed ID: 20598852
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Femoral nerve blockade during endovenous laser ablation of great saphenous vein decreases pain but does not affect the use of opioids during the procedure.
    Hurmerinta-Kurkijärvi O; Weselius EM; Halmesmäki K; Vikatmaa P; Vikatmaa L; Venermo M
    J Vasc Surg Venous Lymphat Disord; 2023 Sep; 11(5):921-927. PubMed ID: 37142055
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A randomized, controlled trial of endovenous thermal ablation using the 810-nm wavelength laser and the ClosurePLUS radiofrequency ablation methods for superficial venous insufficiency of the great saphenous vein.
    Gale SS; Lee JN; Walsh ME; Wojnarowski DL; Comerota AJ
    J Vasc Surg; 2010 Sep; 52(3):645-50. PubMed ID: 20638231
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Does the direction of tumescent solution delivery matter in endovenous laser ablation of the great saphenous vein?
    Kutas B; Ozdemir F; Tezcan O; Gunes T; Erkoc K; Altin F; Karahan O
    Ther Adv Cardiovasc Dis; 2015 Dec; 9(6):397-402. PubMed ID: 26289048
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Less painful tumescent solution for patients undergoing endovenous laser ablation of the saphenous vein.
    Gunes T; Altin F; Kutas B; Aydin S; Erkoc K; Eygi B; Alur I; Ozdemir F
    Ann Vasc Surg; 2015 Aug; 29(6):1123-7. PubMed ID: 26004966
    [TBL] [Abstract][Full Text] [Related]  

  • 9. 1470 nm diode laser for endovenous ablation (EVLA) of incompetent saphenous veins - a prospective randomized pilot study comparing warm and cold tumescence anaesthesia.
    Pannier F; Rabe E; Maurins U
    Vasa; 2010 Aug; 39(3):249-55. PubMed ID: 20737384
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Endovenous laser treatment of the small saphenous vein.
    Kontothanassis D; Di Mitri R; Ferrari Ruffino S; Zambrini E; Camporese G; Gerard JL; Labropoulos N
    J Vasc Surg; 2009 Apr; 49(4):973-979.e1. PubMed ID: 19341887
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Endovenous laser ablation of the small saphenous vein: prospective analysis of 150 patients, a cohort study.
    Huisman LC; Bruins RM; van den Berg M; Hissink RJ
    Eur J Vasc Endovasc Surg; 2009 Aug; 38(2):199-202. PubMed ID: 19616756
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparing local tumescent anesthesia and spinal anesthesia methods during and after endovenous radiofrequency ablation of great saphenous vein.
    Bitargil M; El Kiliç H
    Int Angiol; 2020 Dec; 39(6):461-466. PubMed ID: 32672433
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Risks of combination technique.
    Kurdal AT; Iskesen I
    Interact Cardiovasc Thorac Surg; 2010 Dec; 11(6):777-8. PubMed ID: 21097458
    [No Abstract]   [Full Text] [Related]  

  • 14. Comparing cold and warm tumescent anesthesia for pain perception during and after the endovenous laser ablation procedure with 1470 nm diode laser.
    Dumantepe M; Uyar I
    Phlebology; 2015 Feb; 30(1):45-51. PubMed ID: 24243931
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Endovenous laser ablation of the saphenous vein for treatment of venous insufficiency and varicose veins: early results from a large single-center experience.
    Perkowski P; Ravi R; Gowda RC; Olsen D; Ramaiah V; Rodriguez-Lopez JA; Diethrich EB
    J Endovasc Ther; 2004 Apr; 11(2):132-8. PubMed ID: 15056020
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparative study of the efficacy of endovenous laser treatment of the incompetent great saphenous under general anesthesia with external air cooling with and without tumescent anesthesia.
    Hernández Osma E; Mordon SR; Marqa MF; Vokurka J; Trelles MA
    Dermatol Surg; 2013 Feb; 39(2):255-62. PubMed ID: 23227920
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Nitrous oxide/oxygen inhalation provides effective analgesia during the administration of tumescent local anaesthesia for endovenous laser ablation.
    Meier TO; Jacomella V; Clemens RK; Amann-Vesti B
    Vasa; 2015 Nov; 44(6):473-8. PubMed ID: 26515225
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Tumescentless endovenous radiofrequency ablation with local hypothermia and compression technique.
    Korkmaz K; Yener AÜ; Gedık HS; Budak AB; Yener Ö; Genç SB; Lafçi A
    Cardiovasc J Afr; 2013 Sep; 24(8):313-7. PubMed ID: 24240382
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Endovenous thermal ablation of superficial venous insufficiency of the lower extremity: single-center experience with 3000 limbs treated in a 7-year period.
    Ravi R; Trayler EA; Barrett DA; Diethrich EB
    J Endovasc Ther; 2009 Aug; 16(4):500-5. PubMed ID: 19702351
    [TBL] [Abstract][Full Text] [Related]  

  • 20. More Successful Results with Less Energy in Endovenous Laser Ablation Treatment: Long-term Comparison of Bare-tip Fiber 980 nm Laser and Radial-tip Fiber 1470 nm Laser Application.
    Arslan Ü; Çalık E; Tort M; Yıldız Z; Tekin Aİ; Limandal HK; Kaygın MA; Dağ Ö; Erkut B
    Ann Vasc Surg; 2017 Nov; 45():166-172. PubMed ID: 28647634
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.