BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

273 related articles for article (PubMed ID: 2085427)

  • 1. High-permeable membranes and hypersensitivity-like reactions: role of dialysis fluid contamination.
    Bigazzi R; Atti M; Baldari G
    Blood Purif; 1990; 8(4):190-8. PubMed ID: 2085427
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A prospective study of pyrogenic reactions in hemodialysis patients using bicarbonate dialysis fluids filtered to remove bacteria and endotoxin.
    Pegues DA; Oettinger CW; Bland LA; Oliver JC; Arduino MJ; Aguero SM; McAllister SK; Gordon SM; Favero MS; Jarvis WR
    J Am Soc Nephrol; 1992 Oct; 3(4):1002-7. PubMed ID: 1450362
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro studies of endotoxin transfer across cellulosic and noncellulosic dialysis membranes. II. Interleukin-1 production.
    Herbelin A; Ureña P; Man NK; Drüeke T; Descamps-Latscha B
    Contrib Nephrol; 1989; 74():79-85. PubMed ID: 2702150
    [No Abstract]   [Full Text] [Related]  

  • 4. [Role of tumor necrosis factor in hemodiafiltration].
    Tetta C; Segoloni G; Fidelio T; Licata C; Sancipriano GP; Iacono G; Ragni R; Vercellone A
    Minerva Urol Nefrol; 1991; 43(3):181-3. PubMed ID: 1817342
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Hypersensitivity reactions during hemodialysis. Role of high permeability, retrofiltration and bacterial contamination of the dialysate].
    Montagnac R; Schillinger F; Milcent T; Croix JC
    Nephrologie; 1988; 9(1):29-32. PubMed ID: 3134622
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pyrogen retention by highly permeable synthetic membranes during in vitro dialysis.
    Lonnemann G; Sereni L; Lemke HD; Tetta C
    Artif Organs; 2001 Dec; 25(12):951-60. PubMed ID: 11843762
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Potential transfer of endotoxin across high-flux polysulfone membranes.
    Bommer J; Becker KP; Urbaschek R
    J Am Soc Nephrol; 1996 Jun; 7(6):883-8. PubMed ID: 8793797
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Induction of interleukin-1 and tumor necrosis factor during in vitro hemodialysis with different membranes.
    Schindler R; Lonnemann G; Shaldon S; Koch KM; Dinarello CA
    Contrib Nephrol; 1989; 74():58-65. PubMed ID: 2702147
    [No Abstract]   [Full Text] [Related]  

  • 9. Pyrogen retention by the Asahi APS-650 polysulfone dialyzer during in vitro dialysis with whole human donor blood.
    Linnenweber S; Lonnemann G
    ASAIO J; 2000; 46(4):444-7. PubMed ID: 10926143
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Filtration of dialysate using an on-line dialysate filter.
    Frinak S; Polaschegg HD; Levin NW; Pohlod DJ; Dumler F; Saravolatz LD
    Int J Artif Organs; 1991 Nov; 14(11):691-7. PubMed ID: 1757155
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Incidence of Hypersensitivity Reactions During Hemodialysis.
    Esteras R; Martín-Navarro J; Ledesma G; Fernández-Prado R; Carreño G; Cintra M; Cidraque I; Sanz I; Tarragón B; Alexandru S; Milla M; Astudillo E; Sánchez E; Mas S; Tejeiro RD; Ortiz A; Sánchez R; González-Parra E
    Kidney Blood Press Res; 2018; 43(5):1472-1478. PubMed ID: 30235456
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Induction of IL-1 during hemodialysis: transmembrane passage of intact endotoxins (LPS).
    Laude-Sharp M; Caroff M; Simard L; Pusineri C; Kazatchkine MD; Haeffner-Cavaillon N
    Kidney Int; 1990 Dec; 38(6):1089-94. PubMed ID: 2127434
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effects of endotoxin-contaminated dialysate and polysulfone or cellulosic membranes on the release of TNF alpha during simulated dialysis.
    Arduino MJ; Bland LA; McAllister SK; Favero MS
    Artif Organs; 1995 Sep; 19(9):880-6. PubMed ID: 8687293
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The past, present and future of the dialyzer.
    Mineshima M
    Contrib Nephrol; 2015; 185():8-14. PubMed ID: 26023010
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ultrafiltration and endotoxin removal from dialysis fluids.
    Di Felice A; Cappelli G; Facchini F; Tetta C; Cornia F; Aimo G; Lusvarghi E
    Kidney Int Suppl; 1993 Jun; 41():S201-4. PubMed ID: 8320921
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In vitro studies of endotoxin transfer across cellulosic and noncellulosic dialysis membranes. I. Radiolabeled endotoxin.
    Ureña P; Herbelin A; Basile C; Zingraff J; Man NK; Drüeke T
    Contrib Nephrol; 1989; 74():71-8. PubMed ID: 2702149
    [No Abstract]   [Full Text] [Related]  

  • 17. Membranes for endotoxin removal from dialysate: considerations on feasibility of commercial ceramic membranes.
    Bender H; Pfläzel A; Saunders N; Czermak P; Catapano G; Vienken J
    Artif Organs; 2000 Oct; 24(10):826-9. PubMed ID: 11091173
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical evaluation of four different high-flux hemodialyzers under conventional conditions in vivo.
    Sombolos K; Tsitamidou Z; Kyriazis G; Karagianni A; Kantaropoulou M; Progia E
    Am J Nephrol; 1997; 17(5):406-12. PubMed ID: 9382156
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pyrogenic reactions in patients receiving conventional, high-efficiency, or high-flux hemodialysis treatments with bicarbonate dialysate containing high concentrations of bacteria and endotoxin.
    Gordon SM; Oettinger CW; Bland LA; Oliver JC; Arduino MJ; Aguero SM; McAllister SK; Favero MS; Jarvis WR
    J Am Soc Nephrol; 1992 Mar; 2(9):1436-44. PubMed ID: 1627766
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Characterization of the DialGuard device for endotoxin removal in hemodialysis.
    Szathmary S; Hegyi E; Amoureux MC; Rajapakse N; Chicorka L; Szalai G; Reszegi K; Derbyshire Z; Paluh J; Dodson B; Grandics P
    Blood Purif; 2004; 22(5):409-15. PubMed ID: 15316195
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.