194 related articles for article (PubMed ID: 20856998)
1. Machined and plastic copings in three-element prostheses with different types of implant-abutment joints: a strain gauge comparative analysis.
Nishioka RS; Nishioka LN; Abreu CW; de Vasconcellos LG; Balducci I
J Appl Oral Sci; 2010; 18(3):225-30. PubMed ID: 20856998
[TBL] [Abstract][Full Text] [Related]
2. Axial loads on implant-supported partial fixed prostheses for external and internal hex connections and machined and plastic copings: strain gauge analysis.
de Vasconcellos LG; Kojima AN; Nishioka RS; de Vasconcellos LM; Balducci I
J Oral Implantol; 2015 Apr; 41(2):149-54. PubMed ID: 23574373
[TBL] [Abstract][Full Text] [Related]
3. Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysis.
Vasconcellos LG; Nishioka RS; Vasconcellos LM; Nishioka LN
J Appl Oral Sci; 2011; 19(6):610-5. PubMed ID: 22230995
[TBL] [Abstract][Full Text] [Related]
4. Microstrain around dental implants supporting fixed partial prostheses under axial and non-axial loading conditions, in vitro strain gauge analysis.
de Vasconcellos LG; Nishioka RS; de Vasconcellos LM; Balducci I; Kojima AN
J Craniofac Surg; 2013 Nov; 24(6):e546-51. PubMed ID: 24220463
[TBL] [Abstract][Full Text] [Related]
5. Straight and offset implant placement under axial and nonaxial loads in implant-supported prostheses: strain gauge analysis.
Abreu CW; Nishioka RS; Balducci I; Consani RL
J Prosthodont; 2012 Oct; 21(7):535-9. PubMed ID: 22905920
[TBL] [Abstract][Full Text] [Related]
6. External hexagon and internal hexagon in straight and offset implant placement: strain gauge analysis.
Nishioka RS; de Vasconcellos LG; de Melo Nishioka LN
Implant Dent; 2009 Dec; 18(6):512-20. PubMed ID: 20009605
[TBL] [Abstract][Full Text] [Related]
7. Implant abutment deformation during prosthetic cylinder screw tightening: an in vitro study.
Neto RT; Moura MS; Souza EA; Rubo JH
Int J Prosthodont; 2009; 22(4):391-5. PubMed ID: 19639078
[TBL] [Abstract][Full Text] [Related]
8. Microstrains around standard and mini implants supporting different bridge designs.
Sallam H; Kheiralla LS; Aldawakly A
J Oral Implantol; 2012 Jun; 38(3):221-9. PubMed ID: 20712439
[TBL] [Abstract][Full Text] [Related]
9. The effect of repeated torque in small diameter implants with machined and premachined abutments.
Saboury A; Neshandar Asli H; Vaziri S
Clin Implant Dent Relat Res; 2012 May; 14 Suppl 1():e224-30. PubMed ID: 22376004
[TBL] [Abstract][Full Text] [Related]
10. Analysis of stress distribution in a screw-retained implant prosthesis.
Watanabe F; Uno I; Hata Y; Neuendorff G; Kirsch A
Int J Oral Maxillofac Implants; 2000; 15(2):209-18. PubMed ID: 10795453
[TBL] [Abstract][Full Text] [Related]
11. Preload and torque removal evaluation of three different abutment screws for single standing implant restorations.
Stüker RA; Teixeira ER; Beck JC; da Costa NP
J Appl Oral Sci; 2008; 16(1):55-8. PubMed ID: 19089290
[TBL] [Abstract][Full Text] [Related]
12. Marginal fit and photoelastic stress analysis of CAD-CAM and overcast 3-unit implant-supported frameworks.
Presotto AG; Bhering CL; Mesquita MF; Barão VA
J Prosthet Dent; 2017 Mar; 117(3):373-379. PubMed ID: 27666497
[TBL] [Abstract][Full Text] [Related]
13. Deformation of implant abutments after framework connection using strain gauges.
Hollweg H; Jacques LB; da Silva Moura M; Bianco VC; Souza EA; Rubo JH
J Oral Implantol; 2012 Apr; 38(2):125-32. PubMed ID: 22568468
[TBL] [Abstract][Full Text] [Related]
14. In vitro evaluation of reverse torque value of abutment screw and marginal opening in a screw- and cement-retained implant fixed partial denture design.
Kim SG; Park JU; Jeong JH; Bae C; Bae TS; Chee W
Int J Oral Maxillofac Implants; 2009; 24(6):1061-7. PubMed ID: 20162110
[TBL] [Abstract][Full Text] [Related]
15. Axial displacements in external and internal implant-abutment connection.
Lee JH; Kim DG; Park CJ; Cho LR
Clin Oral Implants Res; 2014 Feb; 25(2):e83-9. PubMed ID: 23088616
[TBL] [Abstract][Full Text] [Related]
16. Influence of different tightening forces before laser welding to the implant/framework fit.
da Silveira-Júnior CD; Neves FD; Fernandes-Neto AJ; Prado CJ; Simamoto-Júnior PC
J Prosthodont; 2009 Jun; 18(4):337-41. PubMed ID: 19210612
[TBL] [Abstract][Full Text] [Related]
17. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies.
Byrne D; Jacobs S; O'Connell B; Houston F; Claffey N
J Prosthodont; 2006; 15(3):164-71. PubMed ID: 16681498
[TBL] [Abstract][Full Text] [Related]
18. Fit and Stability of Screw-Retained Implant-Supported Frameworks Under Masticatory Simulation: Influence of Cylinder Type.
Bhering CL; Marques Ida S; Takahashi JM; Barão VA; Consani RL; Mesquita MF
J Prosthodont; 2016 Aug; 25(6):459-65. PubMed ID: 26465960
[TBL] [Abstract][Full Text] [Related]
19. Effect of engaging abutment position in implant-borne, screw-retained three-unit fixed cantilevered prostheses.
Dogus SM; Kurtz KS; Watanabe I; Griggs JA
J Prosthodont; 2011 Jul; 20(5):348-54. PubMed ID: 21585587
[TBL] [Abstract][Full Text] [Related]
20. Influence of CAD/CAM on the fit accuracy of implant-supported zirconia and cobalt-chromium fixed dental prostheses.
de França DG; Morais MH; das Neves FD; Barbosa GA
J Prosthet Dent; 2015 Jan; 113(1):22-8. PubMed ID: 25277028
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]