These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

95 related articles for article (PubMed ID: 20862400)

  • 1. Insertion torque in different bone models with different screw pitch: an in vitro study.
    Orlando B; Barone A; Giorno TM; Giacomelli L; Tonelli P; Covani U
    Int J Oral Maxillofac Implants; 2010; 25(5):883-7. PubMed ID: 20862400
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study.
    Tabassum A; Meijer GJ; Wolke JG; Jansen JA
    Clin Oral Implants Res; 2010 Feb; 21(2):213-20. PubMed ID: 20070754
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Primary stability, insertion torque and bone density of cylindric implant ad modum Branemark: is there a relationship? An in vitro study.
    Trisi P; De Benedittis S; Perfetti G; Berardi D
    Clin Oral Implants Res; 2011 May; 22(5):567-70. PubMed ID: 21087320
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Adapted preparation technique for screw-type implants: explorative in vitro pilot study in a porcine bone model.
    Beer A; Gahleitner A; Holm A; Birkfellner W; Homolka P
    Clin Oral Implants Res; 2007 Feb; 18(1):103-7. PubMed ID: 17224030
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: a laboratory study.
    Tabassum A; Meijer GJ; Wolke JG; Jansen JA
    Clin Oral Implants Res; 2009 Apr; 20(4):327-32. PubMed ID: 19298286
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A comparison of screw insertion torque and pullout strength.
    Ricci WM; Tornetta P; Petteys T; Gerlach D; Cartner J; Walker Z; Russell TA
    J Orthop Trauma; 2010 Jun; 24(6):374-8. PubMed ID: 20502221
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Implant micromotion is related to peak insertion torque and bone density.
    Trisi P; Perfetti G; Baldoni E; Berardi D; Colagiovanni M; Scogna G
    Clin Oral Implants Res; 2009 May; 20(5):467-71. PubMed ID: 19522976
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Primary stability of turned and acid-etched screw-type implants: a removal torque and histomorphometric study in rabbits.
    Fernandes Ede L; Unikowski IL; Teixeira ER; da Costa NP; Shinkai RS
    Int J Oral Maxillofac Implants; 2007; 22(6):886-92. PubMed ID: 18271369
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mechanical stability of immediately loaded implants with various surfaces and designs: a pilot study in dogs.
    Neugebauer J; Weinländer M; Lekovic V; von Berg KH; Zoeller JE
    Int J Oral Maxillofac Implants; 2009; 24(6):1083-92. PubMed ID: 20162113
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Quantifying the influence of bone density and thickness on resonance frequency analysis: an in vitro study of biomechanical test materials.
    Bardyn T; Gédet P; Hallermann W; Büchler P
    Int J Oral Maxillofac Implants; 2009; 24(6):1006-14. PubMed ID: 20162104
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study.
    Turkyilmaz I; Sennerby L; Yilmaz B; Bilecenoglu B; Ozbek EN
    Clin Implant Dent Relat Res; 2009 Mar; 11(1):52-8. PubMed ID: 18384400
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effects of implant surface roughness and surgical technique on implant fixation in an in vitro model.
    Shalabi MM; Wolke JG; Jansen JA
    Clin Oral Implants Res; 2006 Apr; 17(2):172-8. PubMed ID: 16584413
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Primary stability, insertion torque, and bone density of conical implants with internal hexagon: is there a relationship?
    Trisi P; Berardi D; Paolantonio M; Spoto G; D'Addona A; Perfetti G
    J Craniofac Surg; 2013 May; 24(3):841-4. PubMed ID: 23714893
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Torque of endosseous dental screw type implants].
    Schmid MR; Schiel HJ; Lambrecht JT
    Schweiz Monatsschr Zahnmed; 2002; 112(8):804-13. PubMed ID: 12244931
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Required minimum primary stability and torque values for immediate loading of mini dental implants: an experimental study in nonviable bovine femoral bone.
    Dilek O; Tezulas E; Dincel M
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2008 Feb; 105(2):e20-7. PubMed ID: 18230373
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Is insertion torque correlated to bone-implant contact percentage in the early healing period? A histological and histomorphometrical evaluation of 17 human-retrieved dental implants.
    Degidi M; Perrotti V; Strocchi R; Piattelli A; Iezzi G
    Clin Oral Implants Res; 2009 Aug; 20(8):778-81. PubMed ID: 19486080
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Torque-fitting and resonance frequency analyses of implants in conventional sockets versus controlled bone defects in vitro.
    Akça K; Kökat AM; Cömert A; Akkocaoğlu M; Tekdemir I; Cehreli MC
    Int J Oral Maxillofac Surg; 2010 Feb; 39(2):169-73. PubMed ID: 20036107
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical outcome of 802 immediately loaded 2-stage submerged implants with a new grit-blasted and acid-etched surface: 12-month follow-up.
    Degidi M; Piattelli A; Gehrke P; Carinci F
    Int J Oral Maxillofac Implants; 2006; 21(5):763-8. PubMed ID: 17066638
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The biomechanical effect of artificial and human bone density on stopping and stripping torque during screw insertion.
    Tsuji M; Crookshank M; Olsen M; Schemitsch EH; Zdero R
    J Mech Behav Biomed Mater; 2013 Jun; 22():146-56. PubMed ID: 23578764
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Implant design and intraosseous stability of immediately placed implants: a human cadaver study.
    Akkocaoglu M; Uysal S; Tekdemir I; Akca K; Cehreli MC
    Clin Oral Implants Res; 2005 Apr; 16(2):202-9. PubMed ID: 15777330
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.