These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

76 related articles for article (PubMed ID: 2086466)

  • 1. Ultrasonic measurements of extraocular muscle thickness in normal Indian population.
    Arora R; Verma L; Kumar A
    Indian J Ophthalmol; 1990; 38(4):164-5. PubMed ID: 2086466
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Echographic measurement of extraocular muscles in vivo].
    Du YY
    Zhonghua Yan Ke Za Zhi; 1990 Sep; 26(5):279-81. PubMed ID: 2086138
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [MRI study of the thickness and width of the extraocular muscles in normal subjects].
    Li R; Xia S; Wang J; Sun F; Qi J
    Zhonghua Yan Ke Za Zhi; 2015 Jun; 51(6):434-8. PubMed ID: 26310117
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Echographic study of extraocular muscle thickness in children and adults.
    Saccà S; Polizzi A; Macrì A; Patrone G; Rolando M
    Eye (Lond); 2000 Oct; 14 Pt 5():765-9. PubMed ID: 11116701
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Echographic measurement of extraocular muscle thickness in proptosis.
    Arora R; Verma L; Sihota R
    Ann Ophthalmol; 1992 Mar; 24(3):106-10. PubMed ID: 1570924
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Normal measurements of extraocular muscle using computed tomography.
    Lerdlum S; Boonsirikamchai P; Setsakol E
    J Med Assoc Thai; 2007 Feb; 90(2):307-12. PubMed ID: 17375636
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Diameter of normal extraocular recti muscles with echography.
    Byrne SF; Gendron EK; Glaser JS; Feuer W; Atta H
    Am J Ophthalmol; 1991 Dec; 112(6):706-13. PubMed ID: 1957908
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of extraocular muscle thickness and correlation study using optical coherence tomography.
    de-Pablo-Gómez-de-Liaño L; Fernández-Vigo JI; Ventura-Abreu N; Benito-Pascual B; Narváez-Palazón C; Gómez-de-Liaño R
    Arch Soc Esp Oftalmol (Engl Ed); 2018 Aug; 93(8):392-397. PubMed ID: 29398235
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [The studies on the measurement of the extraocular muscles. Report 1. Echographic measurements of extraocular muscles thickness applied in normal cases and thyroid orbitopathy (author's transl)].
    Tane S; Shimizu S; Komatsu A; Iguchi T; Ohba H; Sakamoto H; Inafuku Y; Horikoshi J
    Nippon Ganka Gakkai Zasshi; 1980 Oct; 84(10):1686-90. PubMed ID: 6894820
    [No Abstract]   [Full Text] [Related]  

  • 10. Quantitative evaluation of extraocular muscle with high-field magnetic resonance in patients with Graves' ophthalmopathy with upper-lid retraction.
    Chen Y; Jin ZY; Zhang ZH; Xu DD; Meng W; Jiang B; Fang HY; Sun ZY; Chen Y; Sun HY; Feng F
    Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2012 Oct; 34(5):461-7. PubMed ID: 23134821
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Normative measurements of Korean orbital structures revealed by computerized tomography.
    Lee JS; Lim DW; Lee SH; Oum BS; Kim HJ; Lee HJ
    Acta Ophthalmol Scand; 2001 Apr; 79(2):197-200. PubMed ID: 11284763
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Computed tomography measurement of extra-ocular muscle diameters in a population of normal patients in a tertiary hospital in Nigeria.
    Ogbole GI; Ogun OA; Olusumade D
    Afr J Med Med Sci; 2014 Sep; 43(3):245-50. PubMed ID: 26223143
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of standardized echography with magnetic resonance imaging to measure extraocular muscle size.
    Demer JL; Kerman BM
    Am J Ophthalmol; 1994 Sep; 118(3):351-61. PubMed ID: 8085593
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Extraocular muscle insertions relative to the fovea and optic nerve: humans and rhesus macaque.
    Feng X; Pilon K; Yaacobi Y; Olsen TW
    Invest Ophthalmol Vis Sci; 2005 Oct; 46(10):3493-6. PubMed ID: 16186324
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of standardized echography with magnetic resonance imaging to measure extraocular muscle size.
    Harrie RP
    Am J Ophthalmol; 1995 Mar; 119(3):383-4. PubMed ID: 7794329
    [No Abstract]   [Full Text] [Related]  

  • 16. [Insertion of the Tenon capsule onto the rectus muscles].
    De Gottrau P; Gajisin S; Roth A
    J Fr Ophtalmol; 1993; 16(8-9):436-40. PubMed ID: 8282950
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Elasmobranch oculomotor organization: anatomical and theoretical aspects of the phylogenetic development of vestibulo-oculomotor connectivity.
    Graf W; Brunken WJ
    J Comp Neurol; 1984 Aug; 227(4):569-81. PubMed ID: 6470223
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Peripheral and central oculomotor organization in the goldfish, Carassius auratus.
    Graf W; McGurk JF
    J Comp Neurol; 1985 Sep; 239(4):391-401. PubMed ID: 4044944
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Extraocular muscle size comparison between normal and myopic eyes using standardized A scan echography.
    Pierro L; Zaganelli E; Tavola A; Muraglia M
    Ophthalmologica; 1998; 212 Suppl 1():22-4. PubMed ID: 9730741
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Is the insertional anatomy of rectus extraocular muscles binocularly symmetrical?
    Cho HK; Shin SY
    Ophthalmic Res; 2010; 43(4):179-84. PubMed ID: 20068370
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.