These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 20871111)

  • 1. In situ hydride formation in titanium during focused ion milling.
    Ding R; Jones IP
    J Electron Microsc (Tokyo); 2011; 60(1):1-9. PubMed ID: 20871111
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Technique for preparation and characterization in cross-section of oral titanium implant surfaces using focused ion beam and transmission electron microscopy.
    Jarmar T; Palmquist A; Brånemark R; Hermansson L; Engqvist H; Thomsen P
    J Biomed Mater Res A; 2008 Dec; 87(4):1003-9. PubMed ID: 18257067
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Specimen preparation of porous Au for transmission electron microscopy using cryo ion-milling.
    Tanabe T
    J Electron Microsc (Tokyo); 2011; 60(1):35-7. PubMed ID: 20923871
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Damage in III-V compounds during focused ion beam milling.
    Rubanov S; Munroe PR
    Microsc Microanal; 2005 Oct; 11(5):446-55. PubMed ID: 17481325
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Artifacts introduced by ion milling in Al-Li-Cu alloys.
    Singh AK; Imam MA; Sadananda K
    J Electron Microsc Tech; 1988 Apr; 8(4):355-61. PubMed ID: 3199219
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Focused ion beam milling and ultramicrotomy of mineralised ivory dentine for analytical transmission electron microscopy.
    Jantou V; Turmaine M; West GD; Horton MA; McComb DW
    Micron; 2009 Jun; 40(4):495-501. PubMed ID: 19157888
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Location specific in situ TEM straining specimens made using FIB.
    Field RD; Papin PA
    Ultramicroscopy; 2004 Dec; 102(1):23-6. PubMed ID: 15556697
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An appraisal of ultramicrotomy, FIBSEM and cryogenic FIBSEM techniques for the sectioning of biological cells on titanium substrates for TEM investigation.
    Edwards HK; Fay MW; Anderson SI; Scotchford CA; Grant DM; Brown PD
    J Microsc; 2009 Apr; 234(1):16-25. PubMed ID: 19335453
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparative study of ion milling techniques in cross-sectional transmission electron microscope specimen preparation.
    Zielinski EM; Tracy B
    Microsc Res Tech; 1992 Jul; 22(2):199-206. PubMed ID: 1504351
    [No Abstract]   [Full Text] [Related]  

  • 10. Specimen preparation for high-resolution transmission electron microscopy using focused ion beam and Ar ion milling.
    Sasaki H; Matsuda T; Kato T; Muroga T; Iijima Y; Saitoh T; Iwase F; Yamada Y; Izumi T; Shiohara Y; Hirayama T
    J Electron Microsc (Tokyo); 2004; 53(5):497-500. PubMed ID: 15582954
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of a cryogenic stage for an ion-milling instrument.
    Terauchi M; Satou F; Sugizaki H; Suganuma K
    J Electron Microsc (Tokyo); 2011; 60(1):25-7. PubMed ID: 20935132
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of top, angle, and side cleaned FIB samples for TEM analysis.
    Montoya E; Bals S; Rossell MD; Schryvers D; Van Tendeloo G
    Microsc Res Tech; 2007 Dec; 70(12):1060-71. PubMed ID: 17722055
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of gallium focused ion beam milling on preparation of aluminium thin foils.
    Unocic KA; Mills MJ; Daehn GS
    J Microsc; 2010 Dec; 240(3):227-38. PubMed ID: 21077883
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Preparation of thin ceramic monofilaments for TEM observation with novel embedding processes.
    Li S; Feng Z; Zhang L; Wang Y; Chen L
    Ultramicroscopy; 2011 Jan; 111(2):117-22. PubMed ID: 21185455
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Influence of the height of the external hexagon and surface treatment on fatigue life of commercially pure titanium dental implants.
    Gil FJ; Aparicio C; Manero JM; Padros A
    Int J Oral Maxillofac Implants; 2009; 24(4):583-90. PubMed ID: 19885397
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In situ lift-out dedicated techniques using FIB-SEM system for TEM specimen preparation.
    Tomus D; Ng HP
    Micron; 2013 Jan; 44():115-9. PubMed ID: 22664233
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Applications of the FIB lift-out technique for TEM specimen preparation.
    Giannuzzi LA; Drown JL; Brown SR; Irwin RB; Stevie FA
    Microsc Res Tech; 1998 May; 41(4):285-90. PubMed ID: 9633946
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A site-specific focused-ion-beam lift-out method for cryo Transmission Electron Microscopy.
    Rubino S; Akhtar S; Melin P; Searle A; Spellward P; Leifer K
    J Struct Biol; 2012 Dec; 180(3):572-6. PubMed ID: 23000702
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ultrastructural examination of dentin using focused ion-beam cross-sectioning and transmission electron microscopy.
    Nalla RK; Porter AE; Daraio C; Minor AM; Radmilovic V; Stach EA; Tomsia AP; Ritchie RO
    Micron; 2005; 36(7-8):672-80. PubMed ID: 16182542
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of TEM samples of an Mg-Al alloy prepared using FIB milling at the operating voltages of 10 kV and 40 kV.
    Kamino T; Yaguchi T; Kuroda Y; Ohnishi T; Ishitani T; Miyahara Y; Horita Z
    J Electron Microsc (Tokyo); 2004; 53(5):459-63. PubMed ID: 15582947
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.