These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 20875687)

  • 21. Impact of climate change on the domestic indoor environment and associated health risks in the UK.
    Vardoulakis S; Dimitroulopoulou C; Thornes J; Lai KM; Taylor J; Myers I; Heaviside C; Mavrogianni A; Shrubsole C; Chalabi Z; Davies M; Wilkinson P
    Environ Int; 2015 Dec; 85():299-313. PubMed ID: 26453820
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Polychlorinated biphenyls (PCB) in caulking compounds of buildings--assessment of current status in Berlin and new indoor air sources].
    Fromme H; Baldauf AM; Klautke O; Piloty M; Bohrer L
    Gesundheitswesen; 1996 Dec; 58(12):666-72. PubMed ID: 9081511
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Particle loading rates for HVAC filters, heat exchangers, and ducts.
    Waring MS; Siegel JA
    Indoor Air; 2008 Jun; 18(3):209-24. PubMed ID: 18336534
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Modeling the effects of water usage and co-behavior on inhalation exposures to contaminants volatilized from household water.
    Wilkes CR; Small MJ; Davidson CI; Andelman JB
    J Expo Anal Environ Epidemiol; 1996; 6(4):393-412. PubMed ID: 9087861
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Application of the maximum cumulative ratio (MCR) as a screening tool for the evaluation of mixtures in residential indoor air.
    De Brouwere K; Cornelis C; Arvanitis A; Brown T; Crump D; Harrison P; Jantunen M; Price P; Torfs R
    Sci Total Environ; 2014 May; 479-480():267-76. PubMed ID: 24565859
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Levels of ultrafine particles in different microenvironments--implications to children exposure.
    Diapouli E; Chaloulakou A; Spyrellis N
    Sci Total Environ; 2007 Dec; 388(1-3):128-36. PubMed ID: 17888492
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Characterization of PM2.5, gaseous pollutants, and meteorological interactions in the context of time-series health effects models.
    Ito K; Thurston GD; Silverman RA
    J Expo Sci Environ Epidemiol; 2007 Dec; 17 Suppl 2():S45-60. PubMed ID: 18079764
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Infiltration of forest fire and residential wood smoke: an evaluation of air cleaner effectiveness.
    Barn P; Larson T; Noullett M; Kennedy S; Copes R; Brauer M
    J Expo Sci Environ Epidemiol; 2008 Sep; 18(5):503-11. PubMed ID: 18059421
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Urban and rural exposure to indoor air pollution from domestic biomass and coal burning across China.
    Mestl HE; Aunan K; Seip HM; Wang S; Zhao Y; Zhang D
    Sci Total Environ; 2007 May; 377(1):12-26. PubMed ID: 17343898
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparative health impact assessment of local and regional particulate air pollutants in Scandinavia.
    Forsberg B; Hansson HC; Johansson C; Areskoug H; Persson K; Järvholm B
    Ambio; 2005 Feb; 34(1):11-9. PubMed ID: 15789513
    [TBL] [Abstract][Full Text] [Related]  

  • 31. An assessment of the human health risks from exposure to polybrominated diphenyl ethers (PBDEs) in house dust.
    Banasik M; Hardy M; Stedeford T
    Chemosphere; 2009 Oct; 77(5):704-5; author reply 706-7. PubMed ID: 19766289
    [No Abstract]   [Full Text] [Related]  

  • 32. Valuing the health benefits of improving indoor air quality in residences.
    Chau CK; Hui WK; Tse MS
    Sci Total Environ; 2008 May; 394(1):25-38. PubMed ID: 18291444
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Indoor ultrafine particle exposures and home heating systems: a cross-sectional survey of Canadian homes during the winter months.
    Weichenthal S; Dufresne A; Infante-Rivard C; Joseph L
    J Expo Sci Environ Epidemiol; 2007 May; 17(3):288-97. PubMed ID: 17033678
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Secondhand smoke and particulate matter exposure in the home.
    Van Deusen A; Hyland A; Travers MJ; Wang C; Higbee C; King BA; Alford T; Cummings KM
    Nicotine Tob Res; 2009 Jun; 11(6):635-41. PubMed ID: 19351784
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Modeling VOC-odor exposure risk in livestock buildings.
    Liang HM; Liao CM
    Chemosphere; 2007 Jun; 68(4):781-9. PubMed ID: 17300829
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The influence of improved air quality on mortality risks in Erfurt, Germany.
    Peters A; Breitner S; Cyrys J; Stölzel M; Pitz M; Wölke G; Heinrich J; Kreyling W; Küchenhoff H; Wichmann HE
    Res Rep Health Eff Inst; 2009 Feb; (137):5-77; discussion 79-90. PubMed ID: 19554968
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Inhalation of hazardous air pollutants from environmental tobacco smoke in US residences.
    Nazaroff WW; Singer BC
    J Expo Anal Environ Epidemiol; 2004; 14 Suppl 1():S71-7. PubMed ID: 15118748
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Source specific exposure and risk assessment for indoor aerosols.
    Koivisto AJ; Kling KI; Hänninen O; Jayjock M; Löndahl J; Wierzbicka A; Fonseca AS; Uhrbrand K; Boor BE; Jiménez AS; Hämeri K; Maso MD; Arnold SF; Jensen KA; Viana M; Morawska L; Hussein T
    Sci Total Environ; 2019 Jun; 668():13-24. PubMed ID: 30851679
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Exposure to residential indoor air induces heritable DNA mutations in mice.
    Zhou Y; Liu Y; Qiu W; Zeng J; Chen X; Zhou H; Li A; Zhou J
    J Toxicol Environ Health A; 2009; 72(24):1561-6. PubMed ID: 20077230
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Intake fraction for the indoor environment: a tool for prioritizing indoor chemical sources.
    Shin HM; McKone TE; Bennett DH
    Environ Sci Technol; 2012 Sep; 46(18):10063-72. PubMed ID: 22920860
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.