These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Calibration of RF transmitter voltages for hyperpolarized gas MRI. Bashir A; Conradi MS; Woods JC; Quirk JD; Yablonskiy DA Magn Reson Med; 2009 Jan; 61(1):239-43. PubMed ID: 19097199 [TBL] [Abstract][Full Text] [Related]
5. Assessment of flip angle-TR equivalence for standardized dissolved-phase imaging of the lung with hyperpolarized 129Xe MRI. Ruppert K; Amzajerdian F; Hamedani H; Xin Y; Loza L; Achekzai T; Duncan IF; Profka H; Siddiqui S; Pourfathi M; Sertic F; Cereda MF; Kadlecek S; Rizi RR Magn Reson Med; 2019 Mar; 81(3):1784-1794. PubMed ID: 30346083 [TBL] [Abstract][Full Text] [Related]
6. Steady-state free precession with hyperpolarized 3He: experiments and theory. Wild JM; Teh K; Woodhouse N; Paley MN; Fichele S; de Zanche N; Kasuboski L J Magn Reson; 2006 Nov; 183(1):13-24. PubMed ID: 16890464 [TBL] [Abstract][Full Text] [Related]
7. Hyperpolarized 3He lung ventilation imaging with B1-inhomogeneity correction in a single breath-hold scan. Miller GW; Altes TA; Brookeman JR; De Lange EE; Mugler JP MAGMA; 2004 Apr; 16(5):218-26. PubMed ID: 15108030 [TBL] [Abstract][Full Text] [Related]
8. Slice profile effects in 2D slice-selective MRI of hyperpolarized nuclei. Deppe MH; Teh K; Parra-Robles J; Lee KJ; Wild JM J Magn Reson; 2010 Feb; 202(2):180-9. PubMed ID: 19969495 [TBL] [Abstract][Full Text] [Related]
9. Quantification of regional intrapulmonary oxygen partial pressure evolution during apnea by (3)He MRI. Deninger AJ; Eberle B; Ebert M; Grossmann T; Heil W; Kauczor H; Lauer L; Markstaller K; Otten E; Schmiedeskamp J; Schreiber W; Surkau R; Thelen M; Weiler N J Magn Reson; 1999 Dec; 141(2):207-16. PubMed ID: 10579944 [TBL] [Abstract][Full Text] [Related]
10. Measurement of pulmonary partial pressure of oxygen and oxygen depletion rate with hyperpolarized helium-3 MRI: a preliminary reproducibility study on pig model. Yu J; Rajaei S; Ishii M; Law M; Emami K; Woodburn JM; Kadlecek S; Vahdat V; Rizi RR Acad Radiol; 2008 Jun; 15(6):702-12. PubMed ID: 18486007 [TBL] [Abstract][Full Text] [Related]
11. Measurement of regional lung function in rats using hyperpolarized 3helium dynamic MRI. Chen BT; Brau AC; Johnson GA Magn Reson Med; 2003 Jan; 49(1):78-88. PubMed ID: 12509822 [TBL] [Abstract][Full Text] [Related]
12. Fast Determination of Flip Angle and T1 in Hyperpolarized Gas MRI During a Single Breath-Hold. Zhong J; Ruan W; Han Y; Sun X; Ye C; Zhou X Sci Rep; 2016 May; 6():25854. PubMed ID: 27169670 [TBL] [Abstract][Full Text] [Related]
14. B Bdaiwi AS; Costa ML; Plummer JW; Willmering MM; Walkup LL; Cleveland ZI Magn Reson Med; 2023 Aug; 90(2):473-482. PubMed ID: 36989185 [TBL] [Abstract][Full Text] [Related]
15. Reduction of transient signal oscillations in true-FISP using a linear flip angle series magnetization preparation. Deshpande VS; Chung YC; Zhang Q; Shea SM; Li D Magn Reson Med; 2003 Jan; 49(1):151-7. PubMed ID: 12509831 [TBL] [Abstract][Full Text] [Related]
16. Rapid assessment of longitudinal relaxation time in materials and tissues with extremely fast signal decay using UTE sequences and the variable flip angle method. Springer F; Steidle G; Martirosian P; Syha R; Claussen CD; Schick F Invest Radiol; 2011 Oct; 46(10):610-7. PubMed ID: 21577126 [TBL] [Abstract][Full Text] [Related]
17. Rapid and efficient mapping of regional ventilation in the rat lung using hyperpolarized 3He with Flip Angle Variation for Offset of RF and Relaxation (FAVOR). Santyr GE; Lam WW; Ouriadov A Magn Reson Med; 2008 Jun; 59(6):1304-10. PubMed ID: 18506796 [TBL] [Abstract][Full Text] [Related]
18. Closed-form expressions for flip angle variation that maximize total signal in T1-weighted rapid gradient echo MRI. Drobnitzky M; Klose U Med Phys; 2017 Mar; 44(3):873-885. PubMed ID: 28061002 [TBL] [Abstract][Full Text] [Related]
19. Human lung air spaces: potential for MR imaging with hyperpolarized He-3. MacFall JR; Charles HC; Black RD; Middleton H; Swartz JC; Saam B; Driehuys B; Erickson C; Happer W; Cates GD; Johnson GA; Ravin CE Radiology; 1996 Aug; 200(2):553-8. PubMed ID: 8685356 [TBL] [Abstract][Full Text] [Related]
20. Multiple regression method for pulmonary apparent diffusion coefficient measurement by hyperpolarized 3He MRI. Yu J; Ishii M; Kadlecek S; Lipson DA; Emami K; Clark TW; Rajaei S; Rizi RR J Magn Reson Imaging; 2007 May; 25(5):982-91. PubMed ID: 17457799 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]