243 related articles for article (PubMed ID: 20888214)
1. Multiplexed detection and differentiation of the DNA strains for influenza A (H1N1 2009) using a silicon-based microfluidic system.
Kao LT; Shankar L; Kang TG; Zhang G; Tay GK; Rafei SR; Lee CW
Biosens Bioelectron; 2011 Jan; 26(5):2006-11. PubMed ID: 20888214
[TBL] [Abstract][Full Text] [Related]
2. Microchamber array based DNA quantification and specific sequence detection from a single copy via PCR in nanoliter volumes.
Matsubara Y; Kerman K; Kobayashi M; Yamamura S; Morita Y; Tamiya E
Biosens Bioelectron; 2005 Feb; 20(8):1482-90. PubMed ID: 15626601
[TBL] [Abstract][Full Text] [Related]
3. Detection of human novel influenza A (H1N1) viruses using multi-fluorescent real-time RT-PCR.
Dong H; Zhang Y; Xiong H; Yan A; Ding G; Chen Y; Xie L; Chen J; Zhang G; Hao P; Cong L; Lu Y; Che X; Wang X; Li Y; Yuen KY; Zhao G; Jin W
Virus Res; 2010 Jan; 147(1):85-90. PubMed ID: 19883704
[TBL] [Abstract][Full Text] [Related]
4. Real-time PCR microfluidic devices with concurrent electrochemical detection.
Fang TH; Ramalingam N; Xian-Dui D; Ngin TS; Xianting Z; Lai Kuan AT; Peng Huat EY; Hai-Qing G
Biosens Bioelectron; 2009 Mar; 24(7):2131-6. PubMed ID: 19162460
[TBL] [Abstract][Full Text] [Related]
5. Microfluidic genetic analysis with an integrated a-Si:H detector.
Kamei T; Toriello NM; Lagally ET; Blazej RG; Scherer JR; Street RA; Mathies RA
Biomed Microdevices; 2005 Jun; 7(2):147-52. PubMed ID: 15940430
[TBL] [Abstract][Full Text] [Related]
6. Label-free quantitative DNA detection using the liquid core optical ring resonator.
Suter JD; White IM; Zhu H; Shi H; Caldwell CW; Fan X
Biosens Bioelectron; 2008 Feb; 23(7):1003-9. PubMed ID: 18036809
[TBL] [Abstract][Full Text] [Related]
7. An integrated chip capable of performing sample pretreatment and nucleic acid amplification for HIV-1 detection.
Wang JH; Cheng L; Wang CH; Ling WS; Wang SW; Lee GB
Biosens Bioelectron; 2013 Mar; 41():484-91. PubMed ID: 23083906
[TBL] [Abstract][Full Text] [Related]
8. Rapid detection for primary screening of influenza A virus: microfluidic RT-PCR chip and electrochemical DNA sensor.
Yamanaka K; Saito M; Kondoh K; Hossain MM; Koketsu R; Sasaki T; Nagatani N; Ikuta K; Tamiya E
Analyst; 2011 May; 136(10):2064-8. PubMed ID: 21442100
[TBL] [Abstract][Full Text] [Related]
9. A microfluidic device with microbead array for sensitive virus detection and genotyping using quantum dots as fluorescence labels.
Zhang H; Xu T; Li CW; Yang M
Biosens Bioelectron; 2010 Jul; 25(11):2402-7. PubMed ID: 20483585
[TBL] [Abstract][Full Text] [Related]
10. Subtype identification of the novel A H1N1 and other human influenza A viruses using an oligonucleotide microarray.
Kang X; Li Y; Sun H; Wu W; Liu H; Lin F; Qing C; Chang G; Zhu Q; Chen W; Yang Y
Arch Virol; 2010; 155(1):55-61. PubMed ID: 19998047
[TBL] [Abstract][Full Text] [Related]
11. Microfluidic handling of PCR solution and DNA amplification on a reaction chamber array biochip.
Gong H; Ramalingam N; Chen L; Che J; Wang Q; Wang Y; Yang X; Yap PH; Neo CH
Biomed Microdevices; 2006 Jun; 8(2):167-76. PubMed ID: 16688576
[TBL] [Abstract][Full Text] [Related]
12. Highly-integrated lab-on-chip system for point-of-care multiparameter analysis.
Schumacher S; Nestler J; Otto T; Wegener M; Ehrentreich-Förster E; Michel D; Wunderlich K; Palzer S; Sohn K; Weber A; Burgard M; Grzesiak A; Teichert A; Brandenburg A; Koger B; Albers J; Nebling E; Bier FF
Lab Chip; 2012 Feb; 12(3):464-73. PubMed ID: 22038328
[TBL] [Abstract][Full Text] [Related]
13. An integrated, valveless system for microfluidic purification and reverse transcription-PCR amplification of RNA for detection of infectious agents.
Hagan KA; Reedy CR; Uchimoto ML; Basu D; Engel DA; Landers JP
Lab Chip; 2011 Mar; 11(5):957-61. PubMed ID: 21152489
[TBL] [Abstract][Full Text] [Related]
14. An FET-type charge sensor for highly sensitive detection of DNA sequence.
Kim DS; Jeong YT; Park HJ; Shin JK; Choi P; Lee JH; Lim G
Biosens Bioelectron; 2004 Jul; 20(1):69-74. PubMed ID: 15142578
[TBL] [Abstract][Full Text] [Related]
15. A SYBR Green I real-time RT-PCR assay for detection and differentiation of influenza A(H1N1) virus in swine populations.
Liu S; Hou G; Zhuang Q; Shu Y; Chen J; Jiang W; Chen J; Li J
J Virol Methods; 2009 Dec; 162(1-2):184-7. PubMed ID: 19682498
[TBL] [Abstract][Full Text] [Related]
16. Highly sensitive measurements of PNA-DNA hybridization using oxide-etched silicon nanowire biosensors.
Zhang GJ; Chua JH; Chee RE; Agarwal A; Wong SM; Buddharaju KD; Balasubramanian N
Biosens Bioelectron; 2008 Jun; 23(11):1701-7. PubMed ID: 18356037
[TBL] [Abstract][Full Text] [Related]
17. Morpholino-functionalized silicon nanowire biosensor for sequence-specific label-free detection of DNA.
Zhang GJ; Luo ZH; Huang MJ; Tay GK; Lim EJ
Biosens Bioelectron; 2010 Jul; 25(11):2447-53. PubMed ID: 20435462
[TBL] [Abstract][Full Text] [Related]
18. Detection of pandemic influenza A H1N1 virus by multiplex reverse transcription-PCR with a GeXP analyzer.
Qin M; Wang DY; Huang F; Nie K; Qu M; Wang M; Shu YL; Ma XJ
J Virol Methods; 2010 Sep; 168(1-2):255-8. PubMed ID: 20452377
[TBL] [Abstract][Full Text] [Related]
19. An integrated microfluidic chip for DNA/RNA amplification, electrophoresis separation and on-line optical detection.
Huang FC; Liao CS; Lee GB
Electrophoresis; 2006 Aug; 27(16):3297-305. PubMed ID: 16865670
[TBL] [Abstract][Full Text] [Related]
20. Poly-silicon nanowire field-effect transistor for ultrasensitive and label-free detection of pathogenic avian influenza DNA.
Lin CH; Hung CH; Hsiao CY; Lin HC; Ko FH; Yang YS
Biosens Bioelectron; 2009 Jun; 24(10):3019-24. PubMed ID: 19362813
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]