BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

385 related articles for article (PubMed ID: 20889303)

  • 1. Closed-cell stents present with higher velocities on duplex ultrasound compared with open-cell stents after carotid intervention: short- and mid-term results.
    Hussain HG; Aparajita R; Khan SZ; Rezayat C; McKinsey JF; Dayal R
    Ann Vasc Surg; 2011 Jan; 25(1):55-63. PubMed ID: 20889303
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Duplex ultrasound velocity criteria for the stented carotid artery.
    Lal BK; Hobson RW; Tofighi B; Kapadia I; Cuadra S; Jamil Z
    J Vasc Surg; 2008 Jan; 47(1):63-73. PubMed ID: 18178455
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optimal carotid duplex velocity criteria for defining the severity of carotid in-stent restenosis.
    AbuRahma AF; Abu-Halimah S; Bensenhaver J; Dean LS; Keiffer T; Emmett M; Flaherty S
    J Vasc Surg; 2008 Sep; 48(3):589-94. PubMed ID: 18586444
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Open-cell versus closed-cell stent design differences in blood flow velocities after carotid stenting.
    Pierce DS; Rosero EB; Modrall JG; Adams-Huet B; Valentine RJ; Clagett GP; Timaran CH
    J Vasc Surg; 2009 Mar; 49(3):602-6; discussion 606. PubMed ID: 19268763
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Carotid artery velocity characteristics after carotid artery angioplasty and stenting.
    Chahwan S; Miller MT; Pigott JP; Whalen RC; Jones L; Comerota AJ
    J Vasc Surg; 2007 Mar; 45(3):523-6. PubMed ID: 17257803
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Carotid endarterectomy versus stenting: Does the flow really change? An Echo-Color-Doppler analysis.
    Lucatelli P; Fanelli F; Cirelli C; Sacconi B; Anzidei M; Montisci R; Sanfilippo R; Tamponi E; Catalano C; Saba L
    Int J Cardiovasc Imaging; 2015 Apr; 31(4):773-81. PubMed ID: 25697722
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Carotid artery stenting: is there a need to revise ultrasound velocity criteria?
    Lal BK; Hobson RW; Goldstein J; Chakhtoura EY; DurĂ¡n WN
    J Vasc Surg; 2004 Jan; 39(1):58-66. PubMed ID: 14718815
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Carotid duplex ultrasound velocity measurements versus intravascular ultrasound in detecting carotid in-stent restenosis.
    Yan BP; Clark DJ; Jaff MR; Kiernan TJ; Schainfeld RM; Lessio S; Rosenfield K
    Circ Cardiovasc Interv; 2009 Oct; 2(5):438-43. PubMed ID: 20031754
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Carotid artery duplex velocity criteria might be equivocal after left ventricular assist device implantation.
    Kronfli A; Atnip RG; Aziz F
    J Vasc Surg; 2021 Nov; 74(5):1609-1617.e1. PubMed ID: 33957226
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Determining in-stent stenosis of carotid arteries by duplex ultrasound criteria.
    Stanziale SF; Wholey MH; Boules TN; Selzer F; Makaroun MS
    J Endovasc Ther; 2005 Jun; 12(3):346-53. PubMed ID: 15943510
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Carotid duplex velocity criteria revisited for the diagnosis of carotid in-stent restenosis.
    AbuRahma AF; Maxwell D; Eads K; Flaherty SK; Stutler T
    Vascular; 2007; 15(3):119-25. PubMed ID: 17573016
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Carotid duplex ultrasound changes associated with left ventricular assist devices.
    Coutsoumpos A; Patel S; Teruya TH; Chiriano J; Bianchi C; Abou-Zamzam AM
    Ann Vasc Surg; 2014 May; 28(4):1030.e7-1030.e11. PubMed ID: 24440186
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ultrasound velocity criteria for carotid in-stent restenosis.
    Chi YW; White CJ; Woods TC; Goldman CK
    Catheter Cardiovasc Interv; 2007 Feb; 69(3):349-54. PubMed ID: 17171655
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ultrasound criteria for severe in-stent restenosis following carotid artery stenting.
    Zhou W; Felkai DD; Evans M; McCoy SA; Lin PH; Kougias P; El-Sayed HF; Lumsden AB
    J Vasc Surg; 2008 Jan; 47(1):74-80. PubMed ID: 18178456
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Characteristics of duplex sonographic parameters over time after successful carotid artery stenting.
    Kim ES; Sun Z; Kapadia S; Bajzer C; Arrigain S; Gornik HL
    J Ultrasound Med; 2012 Aug; 31(8):1169-74. PubMed ID: 22837280
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Proposed duplex velocity criteria for carotid restenosis following carotid endarterectomy with patch closure.
    AbuRahma AF; Stone P; Deem S; Dean LS; Keiffer T; Deem E
    J Vasc Surg; 2009 Aug; 50(2):286-91, 291.e1-2; discussion 291. PubMed ID: 19631861
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Predictive multivariate regression to increase the specificity of carotid duplex ultrasound for high-grade stenosis in asymptomatic patients.
    Carnicelli AP; Stone JJ; Doyle A; Chowdhry A; Gillespie DL; Chandra A
    Ann Vasc Surg; 2014 Aug; 28(6):1548-55. PubMed ID: 24530716
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Grading carotid intrastent restenosis: a 6-year follow-up study.
    Setacci C; Chisci E; Setacci F; Iacoponi F; de Donato G
    Stroke; 2008 Apr; 39(4):1189-96. PubMed ID: 18292382
    [TBL] [Abstract][Full Text] [Related]  

  • 19. B-mode ultrasound measurement of carotid bifurcation stenoses: is it reliable?
    MacKenzie KS; French-Sherry E; Burns K; Pooley T; Bassiouny HS
    Vasc Endovascular Surg; 2002; 36(2):123-35. PubMed ID: 11951099
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Carotid artery stent type influences duplex ultrasonography derived peak systolic velocity: findings of an in-vitro model.
    Spies C; Doshi R; Spoon J; Snell RJ
    Catheter Cardiovasc Interv; 2007 Aug; 70(2):309-15. PubMed ID: 17630677
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.