These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

71 related articles for article (PubMed ID: 2089014)

  • 1. New methods for the development of pneumatic displacement pumps for cardiac assist.
    Knierbein B; Rosarius N; Reul H; Rau G
    Int J Artif Organs; 1990 Nov; 13(11):751-9. PubMed ID: 2089014
    [TBL] [Abstract][Full Text] [Related]  

  • 2. CAD-design, stress analysis and in vitro evaluation of three leaflet blood-pump valves.
    Knierbein B; Rosarius N; Unger A; Reul H; Rau G
    J Biomed Eng; 1992 Jul; 14(4):275-86. PubMed ID: 1513132
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Nonthrombogenic, adhesive cellular lining for left ventricular assist devices.
    Scott-Burden T; Tock CL; Bosely JP; Clubb FJ; Parnis SM; Schwarz JJ; Engler DA; Frazier OH; Casscells SW
    Circulation; 1998 Nov; 98(19 Suppl):II339-45. PubMed ID: 9852924
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Muscle powered blood pump: design and initial test results.
    Trumble DR; Magovern JA
    ASAIO J; 1999; 45(3):178-82. PubMed ID: 10360719
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Design and test of non-blood contacting pneumatic ventricle assistance device].
    Wu S; Yang M; Huang H; Li H
    Zhongguo Yi Liao Qi Xie Za Zhi; 2011 Nov; 35(6):398-401. PubMed ID: 22379763
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A teaspoon pump for pumping blood with high hydraulic efficiency and low hemolysis potential.
    Dame D
    Artif Organs; 1996 Jun; 20(6):613-7. PubMed ID: 8817965
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The Hemopump--a new cardiac prothesis device.
    Butler KC; Moise JC; Wampler RK
    IEEE Trans Biomed Eng; 1990 Feb; 37(2):193-6. PubMed ID: 2312144
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [The research and manufacture of the pneumatic left ventricular assist pump].
    Gao W; Cheng A; Xiao X; Fan R; Ding Y; Luo Z; Ye C
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2000 Sep; 17(3):351-3. PubMed ID: 11285855
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Finite element analysis of stresses developed in blood sacs of a pusherplate blood pump.
    Donahue TL; Rosenberg G; Jacobs CR; Weiss WJ
    Comput Methods Biomech Biomed Engin; 2003 Feb; 6(1):7-15. PubMed ID: 12623433
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vitro flow characteristics of a new pump with a high inherent sensitivity to venous return.
    Liska J; Lundbäck S; Semb BK
    ASAIO Trans; 1991; 37(4):592-7. PubMed ID: 1768495
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Methods of failure and reliability assessment for mechanical heart pumps.
    Patel SM; Allaire PE; Wood HG; Throckmorton AL; Tribble CG; Olsen DB
    Artif Organs; 2005 Jan; 29(1):15-25. PubMed ID: 15644079
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Development of a miniature intraventricular axial flow blood pump.
    Yamazaki K; Umezu M; Koyanagi H; Outa E; Ogino S; Otake Y; Shiozaki H; Fujimoto T; Tagusari O; Kitamura M
    ASAIO J; 1993; 39(3):M224-30. PubMed ID: 8268533
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Application of computational fluid dynamics techniques to blood pumps.
    Sukumar R; Athavale MM; Makhijani VB; Przekwas AJ
    Artif Organs; 1996 Jun; 20(6):529-33. PubMed ID: 8817950
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Microtextured materials for circulatory support devices: preliminary studies.
    Zapanta CM; Griffith JW; Hess GD; Doxtater BJ; Khalapyan T; Pae WE; Rosenberg G
    ASAIO J; 2006; 52(1):17-23. PubMed ID: 16436885
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Design, simulation, and fabrication of a three-dimensional printed pump mimicking the left ventricle motion.
    Vignali E; Manigrasso Z; Gasparotti E; Biffi B; Landini L; Positano V; Capelli C; Celi S
    Int J Artif Organs; 2019 Oct; 42(10):539-547. PubMed ID: 31269860
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The valvo-pump. An axial, nonpulsatile blood pump.
    Mitamura Y; Yozu R; Tanaka T; Yamazaki K
    ASAIO Trans; 1991; 37(3):M510-2. PubMed ID: 1751257
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Rotary piston blood pumps: past developments and future potential of a unique pump type.
    Wappenschmidt J; Autschbach R; Steinseifer U; Schmitz-Rode T; Margreiter R; Klima G; Goetzenich A
    Expert Rev Med Devices; 2016 Aug; 13(8):759-71. PubMed ID: 27353827
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Compact mock loops of the systemic and pulmonary circulation for blood pump testing.
    Knierbein B; Reul H; Eilers R; Lange M; Kaufmann R; Rau G
    Int J Artif Organs; 1992 Jan; 15(1):40-8. PubMed ID: 1551727
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Experimental and Numerical Investigation of an Axial Rotary Blood Pump.
    Schüle CY; Thamsen B; Blümel B; Lommel M; Karakaya T; Paschereit CO; Affeld K; Kertzscher U
    Artif Organs; 2016 Nov; 40(11):E192-E202. PubMed ID: 27087467
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Hydrodynamic characterisation of ventricular assist devices.
    Vandenberghe S; Segers P; Meyns B; Verdonck P
    Int J Artif Organs; 2001 Jul; 24(7):470-7. PubMed ID: 11510919
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.