  • 21. Effect of wear of bearing surfaces on elastohydrodynamic lubrication of metal-on-metal hip implants.
    Liu F; Jin ZM; Hirt F; Rieker C; Roberts P; Grigoris P
    Proc Inst Mech Eng H; 2005 Sep; 219(5):319-28. PubMed ID: 16225148
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A general elastohydrodynamic lubrication analysis of artificial hip joints employing a compliant layered socket under steady state rotation.
    Wang FC; Liu F; Jin ZM
    Proc Inst Mech Eng H; 2004; 218(5):283-91. PubMed ID: 15532994
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Cushion form bearings for total knee joint replacement. Part 1: Design,friction and lubrication.
    Auger DD; Dowson D; Fisher J
    Proc Inst Mech Eng H; 1995; 209(2):73-81. PubMed ID: 7495429
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Wear rate evaluation of a novel polycarbonate-urethane cushion form bearing for artificial hip joints.
    Elsner JJ; Mezape Y; Hakshur K; Shemesh M; Linder-Ganz E; Shterling A; Eliaz N
    Acta Biomater; 2010 Dec; 6(12):4698-707. PubMed ID: 20633706
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Kinematics of the MATCO hip simulator and issues related to wear testing of metal-metal implants.
    Medley JB; Krygier JJ; Bobyn JD; Chan FW; Lippincott A; Tanzer M
    Proc Inst Mech Eng H; 1997; 211(1):89-99. PubMed ID: 9141894
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of bearing geometry and structure support on transient elastohydrodynamic lubrication of metal-on-metal hip implants.
    Liu F; Jin Z; Roberts P; Grigoris P
    J Biomech; 2007; 40(6):1340-9. PubMed ID: 16824529
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements.
    Smith SL; Dowson D; Goldsmith AA
    Proc Inst Mech Eng H; 2001; 215(2):161-70. PubMed ID: 11382075
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Metal-on-metal hip joint tribology.
    Dowson D; Jin ZM
    Proc Inst Mech Eng H; 2006 Feb; 220(2):107-18. PubMed ID: 16669380
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Analysis of elastohydrodynamic lubrication in a novel metal-on-metal hip joint replacement.
    Jagatia M; Jin ZM
    Proc Inst Mech Eng H; 2002; 216(3):185-93. PubMed ID: 12137285
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Prediction of lubricating film thickness in UHMWPE hip joint replacements.
    Jalali-Vahid D; Jagatia M; Jin ZM; Dowson D
    J Biomech; 2001 Feb; 34(2):261-6. PubMed ID: 11165292
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Tribology of human and artificial joints.
    Unsworth A
    Proc Inst Mech Eng H; 1991; 205(3):163-72. PubMed ID: 1823790
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effect of 3D physiological loading and motion on elastohydrodynamic lubrication of metal-on-metal total hip replacements.
    Gao L; Wang F; Yang P; Jin Z
    Med Eng Phys; 2009 Jul; 31(6):720-9. PubMed ID: 19269879
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Appropriate radial clearance of ceramic-on-ceramic total hip prostheses to realize squeeze-film lubrication.
    Mabuchi K; Sakai R; Ota M; Ujihira M
    Clin Biomech (Bristol); 2004 May; 19(4):362-9. PubMed ID: 15109756
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Effect of swing phase load on metal-on-metal hip lubrication, friction and wear.
    Williams S; Jalali-Vahid D; Brockett C; Jin Z; Stone MH; Ingham E; Fisher J
    J Biomech; 2006; 39(12):2274-81. PubMed ID: 16143337
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The tribological behaviour of different clearance MOM hip joints with lubricants of physiological viscosities.
    Hu XQ; Wood RJ; Taylor A; Tuke MA
    Proc Inst Mech Eng H; 2011 Nov; 225(11):1061-9. PubMed ID: 22292204
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Hard-on-hard lubrication in the artificial hip under dynamic loading conditions.
    Sonntag R; Reinders J; Rieger JS; Heitzmann DW; Kretzer JP
    PLoS One; 2013; 8(8):e71622. PubMed ID: 23940772
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Compliant-layer tibial bearing inserts: friction testing of different materials and designs for a new generation of prostheses that mimic the natural joint.
    Jones E; Scholes SC; Unsworth A; Burgess IC
    Proc Inst Mech Eng H; 2008 Nov; 222(8):1197-208. PubMed ID: 19143414
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Analysis of mixed lubrication mechanism in metal-on-metal hip joint replacements.
    Jin ZM
    Proc Inst Mech Eng H; 2002; 216(1):85-9. PubMed ID: 11905562
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Wear of 36-mm BIOLOX(R) delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions.
    Al-Hajjar M; Fisher J; Tipper JL; Williams S; Jennings LM
    Proc Inst Mech Eng H; 2013 May; 227(5):535-42. PubMed ID: 23637263
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Lubrication and friction prediction in metal-on-metal hip implants.
    Wang FC; Brockett C; Williams S; Udofia I; Fisher J; Jin ZM
    Phys Med Biol; 2008 Mar; 53(5):1277-93. PubMed ID: 18296762