These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 2090816)

  • 1. Effect of prolonged ultrasonic instrumentation on the retention of cemented cast crowns.
    Olin PS
    J Prosthet Dent; 1990 Nov; 64(5):563-5. PubMed ID: 2090816
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of dentin desensitizers and cementing agents on retention of full crowns using standardized crown preparations.
    Yim NH; Rueggeberg FA; Caughman WF; Gardner FM; Pashley DH
    J Prosthet Dent; 2000 Apr; 83(4):459-65. PubMed ID: 10756297
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of cement, cement space, marginal design, seating aid materials, and seating force on crown cementation.
    Wang CJ; Millstein PL; Nathanson D
    J Prosthet Dent; 1992 Jun; 67(6):786-90. PubMed ID: 1403860
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The influence of ultrasound on the retention of cast posts cemented with different agents.
    Gomes AP; Kubo CH; Santos RA; Santos DR; Padilha RQ
    Int Endod J; 2001 Mar; 34(2):93-9. PubMed ID: 11307266
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An evaluation of retention and marginal seating of Ni-Cr alloy cast restorations using three different luting cements: an in vitro study.
    Pattanaik BK; Nagda SJ
    Indian J Dent Res; 2012; 23(1):20-5. PubMed ID: 22842244
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of application of ultrasonic vibrations on the cement bond strength of cemented cast crowns.
    Badawi BA; Mokhtar AH; Sherif AH; Shehata MT
    Egypt Dent J; 1994 Jul; 40(3):833-8. PubMed ID: 9588164
    [No Abstract]   [Full Text] [Related]  

  • 7. The Effect of Temporary Cement Cleaning Methods on the Retention of Crowns.
    Song MY; An H; Park EJ
    J Prosthodont; 2019 Jan; 28(1):e210-e215. PubMed ID: 28598530
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of seating force, margin design, and cement on marginal seal and retention of complete metal crowns.
    Piemjai M
    Int J Prosthodont; 2001; 14(5):412-6. PubMed ID: 12066634
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Retentive strength, disintegration, and marginal quality of luting cements.
    Gorodovsky S; Zidan O
    J Prosthet Dent; 1992 Aug; 68(2):269-74. PubMed ID: 1501173
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of environmental pressure changes during diving on the retentive strength of different luting agents for full cast crowns.
    Lyons KM; Rodda JC; Hood JA
    J Prosthet Dent; 1997 Nov; 78(5):522-7. PubMed ID: 9399198
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of tooth surface roughness on marginal seating and retention of complete metal crowns.
    Tuntiprawon M
    J Prosthet Dent; 1999 Feb; 81(2):142-7. PubMed ID: 9922426
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparison of two methods of removing zinc oxide-eugenol provisional cement residue from the internal surface of cast restorations.
    Mosharraf R; Soleimani B; Sanaee-Nasab M
    J Contemp Dent Pract; 2009 May; 10(3):27-34. PubMed ID: 19430623
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Retention of gold alloy crowns cemented with traditional and resin cements.
    Pinzón LM; Frey GN; Winkler MM; Tate WH; Burgess JO; Powers JM
    Int J Prosthodont; 2009; 22(4):351-3. PubMed ID: 19639070
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Retentive characteristics of dental cementation materials.
    Hunsaker KJ; Christensen GJ; Christensen RP; Cao D; Lewis RG
    Gen Dent; 1993 Nov; 41 Spec No():464-7. PubMed ID: 23087930
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The retention of complete crowns prepared with three different tapers and luted with four different cements.
    Zidan O; Ferguson GC
    J Prosthet Dent; 2003 Jun; 89(6):565-71. PubMed ID: 12815350
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of the retentive properties of a sleeve cast crown/core system with crowns cemented to conventional cast cores.
    Cohen BI; Deutsch AS; Condos S; Musikant BL
    J Prosthet Dent; 1992 Jul; 68(1):63-8. PubMed ID: 1403923
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Retention of metal-ceramic crowns with contemporary dental cements.
    Johnson GH; Lepe X; Zhang H; Wataha JC
    J Am Dent Assoc; 2009 Sep; 140(9):1125-36. PubMed ID: 19723946
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An in vitro assessment of circumferential grooves on the retention of cement-retained implant-supported crowns.
    Lewinstein I; Block L; Lehr Z; Ormianer Z; Matalon S
    J Prosthet Dent; 2011 Dec; 106(6):367-72. PubMed ID: 22133393
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effects of height and surface roughness of abutments and the type of cement on bond strength of cement-retained implant restorations.
    Al Hamad KQ; Al Rashdan BA; Abu-Sitta EH
    Clin Oral Implants Res; 2011 Jun; 22(6):638-44. PubMed ID: 21039897
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The effect of recementation on crown retention.
    Ayad MF; Rosenstiel SF; Woelfel JB
    Int J Prosthodont; 1998; 11(2):177-82. PubMed ID: 9709609
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.