These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

314 related articles for article (PubMed ID: 20927527)

  • 1. Assessment of tissue perfusion by contrast-enhanced ultrasound.
    Quaia E
    Eur Radiol; 2011 Mar; 21(3):604-15. PubMed ID: 20927527
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Rest-Stress Limb Perfusion Imaging in Humans with Contrast Ultrasound Using Intermediate-Power Imaging and Microbubbles Resistant to Inertial Cavitation.
    Davidson BP; Hodovan J; Belcik JT; Moccetti F; Xie A; Ammi AY; Lindner JR
    J Am Soc Echocardiogr; 2017 May; 30(5):503-510.e1. PubMed ID: 28238588
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Improved modelling of ultrasound contrast agent diminution for blood perfusion analysis.
    Kier C; Meyer-Wiethe K; Seidel G; Mertins A
    Med Image Comput Comput Assist Interv; 2009; 12(Pt 2):935-42. PubMed ID: 20426201
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Perfusion estimation using contrast-enhanced 3-dimensional subharmonic ultrasound imaging: an in vivo study.
    Sridharan A; Eisenbrey JR; Liu JB; Machado P; Halldorsdottir VG; Dave JK; Zhao H; He Y; Park S; Dianis S; Wallace K; Thomenius KE; Forsberg F
    Invest Radiol; 2013 Sep; 48(9):654-60. PubMed ID: 23695085
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantitative evaluation of microvascular blood flow by contrast-enhanced ultrasound (CEUS).
    Greis C
    Clin Hemorheol Microcirc; 2011; 49(1-4):137-49. PubMed ID: 22214685
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Microcirculation volumetric flow assessment using high-resolution, contrast-assisted images.
    Yeh CK; Lu SY; Chen YS
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Jan; 55(1):74-83. PubMed ID: 18334315
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dynamic contrast-enhanced ultrasound and transient arterial occlusion for quantification of arterial perfusion reserve in peripheral arterial disease.
    Amarteifio E; Wormsbecher S; Krix M; Demirel S; Braun S; Delorme S; Böckler D; Kauczor HU; Weber MA
    Eur J Radiol; 2012 Nov; 81(11):3332-8. PubMed ID: 22285606
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Perfusion quantification in contrast-enhanced ultrasound (CEUS)--ready for research projects and routine clinical use.
    Tranquart F; Mercier L; Frinking P; Gaud E; Arditi M
    Ultraschall Med; 2012 Jul; 33 Suppl 1():S31-8. PubMed ID: 22723027
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessment of quantitative perfusion parameters by dynamic contrast-enhanced sonography using a deconvolution method: an in vitro and in vivo study.
    Gauthier M; Tabarout F; Leguerney I; Polrot M; Pitre S; Peronneau P; Lassau N
    J Ultrasound Med; 2012 Apr; 31(4):595-608. PubMed ID: 22441917
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Analysis of echo signal from single ultrasound contrast microbubble using a reversible jump MCMC algorithm.
    Yan Y; Hopgood JR; Sboros V
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():1273-6. PubMed ID: 18002195
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Liver contrast-enhanced sonography: computer-assisted differentiation between focal nodular hyperplasia and inflammatory hepatocellular adenoma by reference to microbubble transport patterns.
    Denis de Senneville B; Frulio N; Laumonier H; Salut C; Lafitte L; Trillaud H
    Eur Radiol; 2020 May; 30(5):2995-3003. PubMed ID: 32002637
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Role of portal vein tumor thrombosis in quantitative perfusion analysis of contrast-enhanced ultrasound of hepatocellular carcinoma.
    Wang Z; Liu G; Lu MD; Xie X; Kuang M; Wang W; Xu Z; Lin M; Chen L
    Ultrasound Med Biol; 2015 May; 41(5):1277-86. PubMed ID: 25623820
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dynamic contrast-enhanced ultrasound for quantification of tissue perfusion.
    Fröhlich E; Muller R; Cui XW; Schreiber-Dietrich D; Dietrich CF
    J Ultrasound Med; 2015 Feb; 34(2):179-96. PubMed ID: 25614391
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Perfusion parameters derived from bolus-tracking perfusion imaging are immune to tracer recirculation.
    Kosior JC; Frayne R
    J Magn Reson Imaging; 2010 Mar; 31(3):753-6. PubMed ID: 20187222
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of a Fluid Dynamic Model for Quantitative Contrast-Enhanced Ultrasound Imaging.
    Denis de Senneville B; Novell A; Arthuis C; Mendes V; Dujardin PA; Patat F; Bouakaz A; Escoffre JM; Perrotin F
    IEEE Trans Med Imaging; 2018 Feb; 37(2):372-383. PubMed ID: 28858788
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A Temporal and Spatial Analysis Approach to Automated Segmentation of Microbubble Signals in Contrast-Enhanced Ultrasound Images: Application to Quantification of Active Vascular Density in Human Lower Limbs.
    Cheung WK; Williams KJ; Christensen-Jeffries K; Dharmarajah B; Eckersley RJ; Davies AH; Tang MX
    Ultrasound Med Biol; 2017 Oct; 43(10):2221-2234. PubMed ID: 28693905
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Real-time contrast ultrasound muscle perfusion imaging with intermediate-power imaging coupled with acoustically durable microbubbles.
    Seol SH; Davidson BP; Belcik JT; Mott BH; Goodman RM; Ammi A; Lindner JR
    J Am Soc Echocardiogr; 2015 Jun; 28(6):718-26.e2. PubMed ID: 25769666
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Enhancement of subharmonic emission from encapsulated microbubbles by using a chirp excitation technique.
    Zhang D; Gong Y; Gong X; Liu Z; Tan K; Zheng H
    Phys Med Biol; 2007 Sep; 52(18):5531-44. PubMed ID: 17804880
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Italian Society of Cardiovascular Echography (SIEC) Consensus Conference on the state of the art of contrast echocardiography.
    Ital Heart J; 2004 Apr; 5(4):309-34. PubMed ID: 15185894
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of Real-Time Two-Dimensional and Three-Dimensional Contrast-Enhanced Ultrasound to Quantify Flow in an In Vitro Model: A Feasibility Study.
    Ruan SM; Zheng Q; Wang Z; Hu HT; Chen LD; Guo HL; Xie XY; Lu MD; Li W; Wang W
    Med Sci Monit; 2019 Dec; 25():10029-10035. PubMed ID: 31879414
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.