BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

110 related articles for article (PubMed ID: 20932123)

  • 1. Acrylic resin polymerization in direct contact to the abutment and the temperature at bone-implant interface: a pilot in vitro study.
    Kazemi M; Jalali H; Eghtedari M; Sadrimanesh R; Sadr-Eshkevari P; Maurer P
    J Oral Implantol; 2012 Oct; 38(5):595-601. PubMed ID: 20932123
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An investigation of heat transfer to the implant-bone interface related to exothermic heat generation during setting of autopolymerizing acrylic resins applied directly to an implant abutment.
    Ormianer Z; Laufer BZ; Nissan J; Gross M
    Int J Oral Maxillofac Implants; 2000; 15(6):837-42. PubMed ID: 11151583
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The comparison of provisional luting agents and abutment surface roughness on the retention of provisional implant-supported crowns.
    Kim Y; Yamashita J; Shotwell JL; Chong KH; Wang HL
    J Prosthet Dent; 2006 Jun; 95(6):450-5. PubMed ID: 16765158
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An investigation on heat transfer to the implant-bone interface due to abutment preparation with high-speed cutting instruments.
    Gross M; Laufer BZ; Ormianar Z
    Int J Oral Maxillofac Implants; 1995; 10(2):207-12. PubMed ID: 7744440
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Heat transfer to the implant-bone interface during preparation of a zirconia/alumina abutment.
    Huh JB; Eckert SE; Ko SM; Choi YG
    Int J Oral Maxillofac Implants; 2009; 24(4):679-83. PubMed ID: 19885408
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Heat transfer of impression plasters to an implant-bone interface.
    Nissan J; Gross M; Ormianer Z; Barnea E; Assif D
    Implant Dent; 2006 Mar; 15(1):83-8. PubMed ID: 16569966
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of heat conduction in dental implants after exposure to hot beverages.
    Livne S; Harel N; Piek D; Ormianer Z
    J Prosthet Dent; 2014 Mar; 111(3):228-33. PubMed ID: 24262947
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Temperature changes in dental implants following exposure to hot substances in an ex vivo model.
    Feuerstein O; Zeichner K; Imbari C; Ormianer Z; Samet N; Weiss EI
    Clin Oral Implants Res; 2008 Jun; 19(6):629-33. PubMed ID: 18371098
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effects of a cementing technique in addition to luting agent on the uniaxial retention force of a single-tooth implant-supported restoration: an in vitro study.
    Santosa RE; Martin W; Morton D
    Int J Oral Maxillofac Implants; 2010; 25(6):1145-52. PubMed ID: 21197491
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A technique for verifying implant analog positions in the definitive cast.
    Sadid-Zadeh R; O'Neal SJ; Liu PR; Aponte-Wesson R
    J Prosthet Dent; 2013 Mar; 109(3):192-7. PubMed ID: 23522369
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An alternative direct technique for the fabrication of an implant-supported, screw-retained fixed interim restoration.
    Yilmaz B; McGlumphy E; Purcell B
    J Prosthet Dent; 2012 Feb; 107(2):137-9. PubMed ID: 22304750
    [No Abstract]   [Full Text] [Related]  

  • 12. Accuracy of impression techniques for implants. Part 2 - comparison of splinting techniques.
    Filho HG; Mazaro JV; Vedovatto E; Assunção WG; dos Santos PH
    J Prosthodont; 2009 Feb; 18(2):172-6. PubMed ID: 19178624
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vitro evaluation of reverse torque value of abutment screw and marginal opening in a screw- and cement-retained implant fixed partial denture design.
    Kim SG; Park JU; Jeong JH; Bae C; Bae TS; Chee W
    Int J Oral Maxillofac Implants; 2009; 24(6):1061-7. PubMed ID: 20162110
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In vivo changes in dental implant temperatures during hot beverage intake: a pilot study.
    Ormianer Z; Feuerstein O; Assad R; Samet N; Weiss EI
    Implant Dent; 2009 Feb; 18(1):38-45. PubMed ID: 19212236
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Syncrystallization: a technique for temporization of immediately loaded implants with metal-reinforced acrylic resin restorations.
    Degidi M; Gehrke P; Spanel A; Piattelli A
    Clin Implant Dent Relat Res; 2006; 8(3):123-34. PubMed ID: 16919020
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of 3 luting agents on retention of implant-supported crowns on 2 different abutments.
    Güncü MB; Cakan U; Canay S
    Implant Dent; 2011 Oct; 20(5):349-53. PubMed ID: 21811170
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dental implant thread pitch and its influence on the osseointegration process: an in vivo comparison study.
    Orsini E; Giavaresi G; Trirè A; Ottani V; Salgarello S
    Int J Oral Maxillofac Implants; 2012; 27(2):383-92. PubMed ID: 22442779
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vivo heat transfer capacities of autopolymerizing, heat-polymerizing, and injection-molded acrylic resins.
    Oruc S; Usumez A; Enhos DS; Ozturk N
    Int J Prosthodont; 2006; 19(6):618-20. PubMed ID: 17165304
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of axial wall modification on the retention of cement-retained, implant-supported crowns.
    Tan KM; Masri R; Driscoll CF; Limkangwalmongkol P; Romberg E
    J Prosthet Dent; 2012 Feb; 107(2):80-5. PubMed ID: 22304741
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of temperature increase in the pulp chamber during the polymerization of materials used for the direct fabrication of provisional restorations.
    Michalakis K; Pissiotis A; Hirayama H; Kang K; Kafantaris N
    J Prosthet Dent; 2006 Dec; 96(6):418-23. PubMed ID: 17174659
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.