BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

216 related articles for article (PubMed ID: 2093329)

  • 21. Sterile filtration of dialysate: is it really of no use?
    Bommer J
    Nephrol Dial Transplant; 2001 Oct; 16(10):1992-4. PubMed ID: 11572885
    [No Abstract]   [Full Text] [Related]  

  • 22. Contamination of dialysis water and dialysate. A survey of 30 centers.
    Bambauer R; Schauer M; Jung WK; Daum V; Vienken J
    ASAIO J; 1994; 40(4):1012-6. PubMed ID: 7858320
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Membranes for endotoxin removal from dialysate: considerations on feasibility of commercial ceramic membranes.
    Bender H; Pfläzel A; Saunders N; Czermak P; Catapano G; Vienken J
    Artif Organs; 2000 Oct; 24(10):826-9. PubMed ID: 11091173
    [TBL] [Abstract][Full Text] [Related]  

  • 24. When good water goes bad: how it happens, clinical consequences and possible solutions.
    Lonnemann G
    Blood Purif; 2004; 22(1):124-9. PubMed ID: 14732820
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The performance evaluation of endotoxin retentive filters in haemodialysis.
    Kashiwagi T; Sato K; Kawakami S; Kiyomoto M; Takei H; Suzuki T; Genei H; Nakata H; Iino Y; Katayama Y
    J Nippon Med Sch; 2011; 78(4):214-23. PubMed ID: 21869555
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Should ultra-pure dialysate be mandatory?
    Lonnemann G
    Nephrol Dial Transplant; 2000; 15 Suppl 1():55-9. PubMed ID: 10737168
    [No Abstract]   [Full Text] [Related]  

  • 27. Removal of lipid A and Pseudomonas aeruginosa endotoxin from dialysis fluids by high-flux polysulfone ultrafilter (dialyzer).
    Rafiee-Tehrani M; Farrokhnia R; Falkenhagen D; Weber C
    PDA J Pharm Sci Technol; 1996; 50(5):306-10. PubMed ID: 8973116
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Dialysate and biocompatibility in hemodialysis].
    Berland Y
    Nephrologie; 1998; 19(6):329-34. PubMed ID: 9836194
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Microbial and endotoxin contamination in water and dialysate in the central United States.
    Klein E; Pass T; Harding GB; Wright R; Million C
    Artif Organs; 1990 Apr; 14(2):85-94. PubMed ID: 2350260
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Looking beyond endotoxin: a comparative study of pyrogen retention by ultrafilters used for the preparation of sterile dialyis fluid.
    Glorieux G; Hulko M; Speidel R; Brodbeck K; Krause B; Vanholder R
    Sci Rep; 2014 Sep; 4():6390. PubMed ID: 25227511
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Occurrence of endotoxin in dialysis fluid from 39 dialysis units.
    Kulander L; Nisbeth U; Danielsson BG; Eriksson O
    J Hosp Infect; 1993 May; 24(1):29-37. PubMed ID: 8101200
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Quality of water in hemodialysis centers in Baghdad, Iraq.
    Al-Naseri SK; Mahdi ZM; Hashim MF
    Hemodial Int; 2013 Oct; 17(4):517-22. PubMed ID: 23461710
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Bacterial and endotoxin permeability of hemodialysis membranes.
    Bernick JJ; Port FK; Favero MS; Brown DG
    Kidney Int; 1979 Oct; 16(4):491-6. PubMed ID: 548594
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Monitoring the microbiological quality of dialysate and treated water.
    Asserraji M; Maoujoud A; Belarbi M; Elfarouki R
    Saudi J Kidney Dis Transpl; 2014 Jan; 25(1):91-5. PubMed ID: 24434388
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Routine disinfection of the total dialysis fluid system.
    Gorke A; Kittel J
    EDTNA ERCA J; 2002; 28(3):130-3. PubMed ID: 12371736
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Microbiological survey of dialysate: vantage of use of sterile bag concentrate.
    Pansini S; Degaetano R; Boccassini D; Turi E
    EDTNA ERCA J; 2001; 27(3):132-4. PubMed ID: 11868994
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The level of endotoxins in hemodialysis water and dialysate in Lithuanian hemodialysis centers.
    Skarupskienė I; Bumblytė IA; Tamošaitis D; Venterienė J; Kuzminskis V
    Medicina (Kaunas); 2010; 46(8):556-60. PubMed ID: 20966633
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Purification of dialysis fluid: historical background and perspective.
    Ledebo I
    Blood Purif; 2009; 27 Suppl 1():17-9. PubMed ID: 19556758
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Endotoxins modulate chronically tumour necrosis factor alpha and interleukin 6 release by uraemic monocytes.
    Pertosa G; Gesualdo L; Bottalico D; Schena FP
    Nephrol Dial Transplant; 1995; 10(3):328-33. PubMed ID: 7792027
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [High-efficiency membranes and the dialysis solution].
    Agliata S; Airoldi G; Baroni A; Boschetti M; Schweiger K; Fortina F; Ragazzoni E; Cavagnino A
    Minerva Urol Nefrol; 1990; 42(1):39-42. PubMed ID: 2389221
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.