BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

249 related articles for article (PubMed ID: 20934279)

  • 1. Local setup errors in image-guided radiotherapy for head and neck cancer patients immobilized with a custom-made device.
    Giske K; Stoiber EM; Schwarz M; Stoll A; Muenter MW; Timke C; Roeder F; Debus J; Huber PE; Thieke C; Bendl R
    Int J Radiat Oncol Biol Phys; 2011 Jun; 80(2):582-9. PubMed ID: 20934279
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Local setup reproducibility of the spinal column when using intensity-modulated radiation therapy for craniospinal irradiation with patient in supine position.
    Stoiber EM; Giske K; Schubert K; Sterzing F; Habl G; Uhl M; Herfarth K; Bendl R; Debus J
    Int J Radiat Oncol Biol Phys; 2011 Dec; 81(5):1552-9. PubMed ID: 20888708
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Setup uncertainties of anatomical sub-regions in head-and-neck cancer patients after offline CBCT guidance.
    van Kranen S; van Beek S; Rasch C; van Herk M; Sonke JJ
    Int J Radiat Oncol Biol Phys; 2009 Apr; 73(5):1566-73. PubMed ID: 19306753
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Improved setup and positioning accuracy using a three-point customized cushion/mask/bite-block immobilization system for stereotactic reirradiation of head and neck cancer.
    Wang H; Wang C; Tung S; Dimmitt AW; Wong PF; Edson MA; Garden AS; Rosenthal DI; Fuller CD; Gunn GB; Takiar V; Wang XA; Luo D; Yang JN; Wong J; Phan J
    J Appl Clin Med Phys; 2016 May; 17(3):180-189. PubMed ID: 27167275
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The residual setup errors of different IGRT alignment procedures for head and neck IMRT and the resulting dosimetric impact.
    Graff P; Kirby N; Weinberg V; Chen J; Yom SS; Lambert L; Pouliot J
    Int J Radiat Oncol Biol Phys; 2013 May; 86(1):170-6. PubMed ID: 23245281
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Positioning reproducibility with and without rotational corrections for 2 head and neck immobilization systems.
    Courneyea L; Mullins J; Howard M; Foote R; Garces Y; Ma D; Beltran C; Brinkmann D; Pafundi D
    Pract Radiat Oncol; 2015; 5(6):e575-81. PubMed ID: 26169225
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantitative assessment of image-guided radiotherapy for paraspinal tumors.
    Stoiber EM; Lechsel G; Giske K; Muenter MW; Hoess A; Bendl R; Debus J; Huber PE; Thieke C
    Int J Radiat Oncol Biol Phys; 2009 Nov; 75(3):933-40. PubMed ID: 19596172
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Use of deformed intensity distributions for on-line modification of image-guided IMRT to account for interfractional anatomic changes.
    Mohan R; Zhang X; Wang H; Kang Y; Wang X; Liu H; Ang KK; Kuban D; Dong L
    Int J Radiat Oncol Biol Phys; 2005 Mar; 61(4):1258-66. PubMed ID: 15752908
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Correction strategies to manage deformations in head-and-neck radiotherapy.
    van Kranen S; van Beek S; Mencarelli A; Rasch C; van Herk M; Sonke JJ
    Radiother Oncol; 2010 Feb; 94(2):199-205. PubMed ID: 20083316
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dosimetric influences of rotational setup errors on head and neck carcinoma intensity-modulated radiation therapy treatments.
    Fu W; Yang Y; Yue NJ; Heron DE; Saiful Huq M
    Med Dosim; 2013; 38(2):125-32. PubMed ID: 23266161
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Near Real-Time Assessment of Anatomic and Dosimetric Variations for Head and Neck Radiation Therapy via Graphics Processing Unit-based Dose Deformation Framework.
    Qi XS; Santhanam A; Neylon J; Min Y; Armstrong T; Sheng K; Staton RJ; Pukala J; Pham A; Low DA; Lee SP; Steinberg M; Manon R; Chen AM; Kupelian P
    Int J Radiat Oncol Biol Phys; 2015 Jun; 92(2):415-22. PubMed ID: 25847607
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Impact of immobilization on intrafraction motion for spine stereotactic body radiotherapy using cone beam computed tomography.
    Li W; Sahgal A; Foote M; Millar BA; Jaffray DA; Letourneau D
    Int J Radiat Oncol Biol Phys; 2012 Oct; 84(2):520-6. PubMed ID: 22401920
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Detection of treatment setup errors between two CT scans for patients with head and neck cancer.
    Ezzell LC; Hansen EK; Quivey JM; Xia P
    Med Phys; 2007 Aug; 34(8):3233-42. PubMed ID: 17879786
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Is ExacTrac x-ray system an alternative to CBCT for positioning patients with head and neck cancers?
    Clemente S; Chiumento C; Fiorentino A; Simeon V; Cozzolino M; Oliviero C; Califano G; Caivano R; Fusco V
    Med Phys; 2013 Nov; 40(11):111725. PubMed ID: 24320433
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Minimal mask immobilization with optical surface guidance for head and neck radiotherapy.
    Zhao B; Maquilan G; Jiang S; Schwartz DL
    J Appl Clin Med Phys; 2018 Jan; 19(1):17-24. PubMed ID: 29119677
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Correction of patient positioning errors based on in-line cone beam CTs: clinical implementation and first experiences.
    Thilmann C; Nill S; Tücking T; Höss A; Hesse B; Dietrich L; Bendl R; Rhein B; Häring P; Thieke C; Oelfke U; Debus J; Huber P
    Radiat Oncol; 2006 May; 1():16. PubMed ID: 16723023
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Repeat CT imaging and replanning during the course of IMRT for head-and-neck cancer.
    Hansen EK; Bucci MK; Quivey JM; Weinberg V; Xia P
    Int J Radiat Oncol Biol Phys; 2006 Feb; 64(2):355-62. PubMed ID: 16256277
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Image guidance during head-and-neck cancer radiation therapy: analysis of alignment trends with in-room cone-beam computed tomography scans.
    Zumsteg Z; DeMarco J; Lee SP; Steinberg ML; Lin CS; McBride W; Lin K; Wang PC; Kupelian P; Lee P
    Int J Radiat Oncol Biol Phys; 2012 Jun; 83(2):712-9. PubMed ID: 22099037
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reproducibility of patient setup in the seated treatment position: A novel treatment chair design.
    McCarroll RE; Beadle BM; Fullen D; Balter PA; Followill DS; Stingo FC; Yang J; Court LE
    J Appl Clin Med Phys; 2017 Jan; 18(1):223-229. PubMed ID: 28291911
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Adequate margins for random setup uncertainties in head-and-neck IMRT.
    Astreinidou E; Bel A; Raaijmakers CP; Terhaard CH; Lagendijk JJ
    Int J Radiat Oncol Biol Phys; 2005 Mar; 61(3):938-44. PubMed ID: 15708278
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.