These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 20934705)

  • 1. A new technique to measure micromotion distribution around a cementless femoral stem.
    Gortchacow M; Wettstein M; Pioletti DP; Terrier A
    J Biomech; 2011 Feb; 44(3):557-60. PubMed ID: 20934705
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].
    Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Efficient computational method for assessing the effects of implant positioning in cementless total hip replacements.
    Bah MT; Nair PB; Taylor M; Browne M
    J Biomech; 2011 Apr; 44(7):1417-22. PubMed ID: 21295306
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Can the rasp be used to predict intra-operatively the primary stability that can be achieved by press-fitting the stem in cementless hip arthroplasty?
    Varini E; Cristofolini L; Traina F; Viceconti M; Toni A
    Clin Biomech (Bristol, Avon); 2008 May; 23(4):408-14. PubMed ID: 18068878
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical evaluation of different offset versions of a cementless hip prosthesis by 3-dimensional measurement of micromotions.
    Fottner A; Peter CV; Schmidutz F; Wanke-Jellinek L; Schröder C; Mazoochian F; Jansson V
    Clin Biomech (Bristol, Avon); 2011 Oct; 26(8):830-5. PubMed ID: 21536357
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Failure of cementless fixation of the femoral component in total hip arthroplasty.
    Otani T; Whiteside LA
    Orthop Clin North Am; 1992 Apr; 23(2):335-46. PubMed ID: 1570145
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Primary stability of cementless stem in THA improved with reduced interfacial gaps.
    Park Y; Shin H; Choi D; Albert C; Yoon YS
    J Biomech Eng; 2008 Apr; 130(2):021008. PubMed ID: 18412495
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Initial stability of a new uncemented short-stem prosthesis, Spiron®, in dog bone.
    Wiebking U; Birkenhauer B; Krettek C; Gösling T
    Technol Health Care; 2011; 19(4):271-82. PubMed ID: 21849737
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Experimental studies of the effect of surgical technical errors on primary stability of cementless hip endoprosthesis shafts].
    Gebauer D; Refior HJ; Haake M
    Z Orthop Ihre Grenzgeb; 1990; 128(1):100-7. PubMed ID: 2138379
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparisons of the surface micromotions of cementless femoral prosthesis in the horizontal and vertical levels: a network analysis of biomechanical studies.
    Wang B; Li Q; Dong J; Zhou D; Liu F
    J Orthop Surg Res; 2020 Jul; 15(1):293. PubMed ID: 32736633
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Sensitivity of the primary stability of a cementless hip stem to its position and orientation.
    Reggiani B; Cristofolini L; Taddei F; Viceconti M
    Artif Organs; 2008 Jul; 32(7):555-60. PubMed ID: 18638310
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Full-field measurement of micromotion around a cementless femoral stem using micro-CT imaging and radiopaque markers.
    Malfroy Camine V; Rüdiger HA; Pioletti DP; Terrier A
    J Biomech; 2016 Dec; 49(16):4002-4008. PubMed ID: 27823803
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Statistical analysis of interfacial gap in a cementless stem FE model.
    Park Y; Choi D; Hwang DS; Yoon YS
    J Biomech Eng; 2009 Feb; 131(2):021016. PubMed ID: 19102575
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical evaluation of two types of short-stemmed hip prostheses compared to the trust plate prosthesis by three-dimensional measurement of micromotions.
    Fottner A; Schmid M; Birkenmaier C; Mazoochian F; Plitz W; Volkmar J
    Clin Biomech (Bristol, Avon); 2009 Jun; 24(5):429-34. PubMed ID: 19307048
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Primary stability of a robodoc implanted anatomical stem versus manual implantation.
    Nogler M; Polikeit A; Wimmer C; Brückner A; Ferguson SJ; Krismer M
    Clin Biomech (Bristol, Avon); 2004 Feb; 19(2):123-9. PubMed ID: 14967574
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Primary stability of an anatomical cementless hip stem: a statistical analysis.
    Viceconti M; Brusi G; Pancanti A; Cristofolini L
    J Biomech; 2006; 39(7):1169-79. PubMed ID: 15927191
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of a collar on subsidence and local micromotion of cementless femoral stems: in vitro comparative study based on micro-computerised tomography.
    Malfroy Camine V; Rüdiger HA; Pioletti DP; Terrier A
    Int Orthop; 2018 Jan; 42(1):49-57. PubMed ID: 28589313
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Analysis of bone-prosthesis interface micromotion for cementless tibial prosthesis fixation and the influence of loading conditions.
    Chong DY; Hansen UN; Amis AA
    J Biomech; 2010 Apr; 43(6):1074-80. PubMed ID: 20189576
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Finite element modeling of resurfacing hip prosthesis: estimation of accuracy through experimental validation.
    Taddei F; Martelli S; Gill HS; Cristofolini L; Viceconti M
    J Biomech Eng; 2010 Feb; 132(2):021002. PubMed ID: 20370239
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Primary stability in cementless femoral stems: custom-made versus conventional femoral prosthesis.
    Götze C; Steens W; Vieth V; Poremba C; Claes L; Steinbeck J
    Clin Biomech (Bristol, Avon); 2002 May; 17(4):267-73. PubMed ID: 12034119
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.