These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
172 related articles for article (PubMed ID: 20936520)
1. Dual-energy-CT of hypervascular liver lesions in patients with HCC: investigation of image quality and sensitivity. Altenbernd J; Heusner TA; Ringelstein A; Ladd SC; Forsting M; Antoch G Eur Radiol; 2011 Apr; 21(4):738-43. PubMed ID: 20936520 [TBL] [Abstract][Full Text] [Related]
2. Image quality of mean temporal arterial and mean temporal portal venous phase images calculated from low dose dynamic volume perfusion CT datasets in patients with hepatocellular carcinoma and pancreatic cancer. Wang X; Henzler T; Gawlitza J; Diehl S; Wilhelm T; Schoenberg SO; Jin ZY; Xue HD; Smakic A Eur J Radiol; 2016 Nov; 85(11):2104-2110. PubMed ID: 27776665 [TBL] [Abstract][Full Text] [Related]
3. Image fusion in dual energy computed tomography for detection of hypervascular liver hepatocellular carcinoma: phantom and preliminary studies. Kim KS; Lee JM; Kim SH; Kim KW; Kim SJ; Cho SH; Han JK; Choi BI Invest Radiol; 2010 Mar; 45(3):149-57. PubMed ID: 20142749 [TBL] [Abstract][Full Text] [Related]
4. Volumetric low-tube-voltage CT imaging for evaluating hypervascular hepatocellular carcinoma; effects on radiation exposure, image quality, and diagnostic performance. Ichikawa T; Motosugi U; Morisaka H; Sano K; Ali M; Araki T Jpn J Radiol; 2013 Aug; 31(8):521-9. PubMed ID: 23793776 [TBL] [Abstract][Full Text] [Related]
5. Evaluation of image quality, radiation dose and diagnostic performance of dual-energy CT datasets in patients with hepatocellular carcinoma. Anzidei M; Di Martino M; Sacconi B; Saba L; Boni F; Zaccagna F; Geiger D; Kirchin MA; Napoli A; Bezzi M; Catalano C Clin Radiol; 2015 Sep; 70(9):966-73. PubMed ID: 26095726 [TBL] [Abstract][Full Text] [Related]
6. Comparison of low kVp CT and dual-energy CT for the evaluation of hypervascular hepatocellular carcinoma. Yoo J; Lee JM; Yoon JH; Joo I; Lee ES; Jeon SK; Jang S Abdom Radiol (NY); 2021 Jul; 46(7):3217-3226. PubMed ID: 33713160 [TBL] [Abstract][Full Text] [Related]
7. Low tube voltage intermediate tube current liver MDCT: sinogram-affirmed iterative reconstruction algorithm for detection of hypervascular hepatocellular carcinoma. Yu MH; Lee JM; Yoon JH; Baek JH; Han JK; Choi BI; Flohr TG AJR Am J Roentgenol; 2013 Jul; 201(1):23-32. PubMed ID: 23789655 [TBL] [Abstract][Full Text] [Related]
8. Diagnostic performance and image quality of low-tube voltage and low-contrast medium dose protocol with hybrid iterative reconstruction for hepatic dynamic CT. Ichikawa S; Motosugi U; Shimizu T; Kromrey ML; Aikawa Y; Tamada D; Onishi H Br J Radiol; 2021 Dec; 94(1128):20210601. PubMed ID: 34586900 [TBL] [Abstract][Full Text] [Related]
9. Virtual unenhanced imaging of the liver with third-generation dual-source dual-energy CT and advanced modeled iterative reconstruction. De Cecco CN; Muscogiuri G; Schoepf UJ; Caruso D; Wichmann JL; Cannaò PM; Canstein C; Fuller SR; Snider L; Varga-Szemes A; Hardie AD Eur J Radiol; 2016 Jul; 85(7):1257-64. PubMed ID: 27235872 [TBL] [Abstract][Full Text] [Related]
10. Can sinogram-affirmed iterative reconstruction improve the detection of small hypervascular liver nodules with dual-energy CT? Facchetti L; Berta L; Mascaro L; Maroldi R J Comput Assist Tomogr; 2014; 38(5):693-9. PubMed ID: 24834888 [TBL] [Abstract][Full Text] [Related]
11. Dual-energy liver CT: effect of monochromatic imaging on lesion detection, conspicuity, and contrast-to-noise ratio of hypervascular lesions on late arterial phase. Shuman WP; Green DE; Busey JM; Mitsumori LM; Choi E; Koprowicz KM; Kanal KM AJR Am J Roentgenol; 2014 Sep; 203(3):601-6. PubMed ID: 25148163 [TBL] [Abstract][Full Text] [Related]
12. Early detection of hypervascularization in hepatocellular carcinoma (≤2 cm) on hepatic arterial phase with virtual monochromatic imaging: Comparison with low-tube voltage CT. Yamaguchi H; Ichikawa T; Morisaka H; Akai H; Izuka K; Ueno T; Abe O; Tsushima Y Medicine (Baltimore); 2023 Sep; 102(39):e34774. PubMed ID: 37773820 [TBL] [Abstract][Full Text] [Related]
13. Can virtual monochromatic images from dual-energy CT replace low-kVp images for abdominal contrast-enhanced CT in small- and medium-sized patients? Lv P; Zhou Z; Liu J; Chai Y; Zhao H; Guo H; Marin D; Gao J Eur Radiol; 2019 Jun; 29(6):2878-2889. PubMed ID: 30506223 [TBL] [Abstract][Full Text] [Related]
14. Hypodense liver lesions in patients with hepatic steatosis: do we profit from dual-energy computed tomography? Nattenmüller J; Hosch W; Nguyen TT; Skornitzke S; Jöres A; Grenacher L; Kauczor HU; Sommer CM; Stiller W Eur Radiol; 2015 Dec; 25(12):3567-76. PubMed ID: 25981220 [TBL] [Abstract][Full Text] [Related]
15. Abdominal CT: an intra-individual comparison between virtual monochromatic spectral and polychromatic 120-kVp images obtained during the same examination. Yamada Y; Jinzaki M; Hosokawa T; Tanami Y; Abe T; Kuribayashi S Eur J Radiol; 2014 Oct; 83(10):1715-22. PubMed ID: 25015416 [TBL] [Abstract][Full Text] [Related]
16. Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality. Lv P; Liu J; Zhang R; Jia Y; Gao J Korean J Radiol; 2015; 16(3):531-40. PubMed ID: 25995682 [TBL] [Abstract][Full Text] [Related]
17. Low contrast dose protocol involving a 100 kVp tube voltage for hypervascular hepatocellular carcinoma in patients with renal dysfunction. Nakaura T; Nagayama Y; Kidoh M; Nakamura S; Namimoto T; Awai K; Harada K; Yamashita Y Jpn J Radiol; 2015 Sep; 33(9):566-76. PubMed ID: 26162707 [TBL] [Abstract][Full Text] [Related]
18. Effectiveness of temporal and dynamic subtraction images of the liver for detection of small HCC on abdominal CT images: comparison of 3D nonlinear image-warping and 3D global-matching techniques. Okumura E; Sanada S; Suzuki M; Takemura A; Matsui O Radiol Phys Technol; 2011 Jul; 4(2):109-20. PubMed ID: 21229338 [TBL] [Abstract][Full Text] [Related]
19. Use of non-linear image blending with dual-energy CT improves vascular visualization in abdominal angiography. Lv P; Liu J; Wu R; Hou P; Hu L; Gao J Clin Radiol; 2014 Feb; 69(2):e93-9. PubMed ID: 24290775 [TBL] [Abstract][Full Text] [Related]
20. Rapid switching kVp dual energy CT: Value of reconstructed dual energy CT images and organ dose assessment in multiphasic liver CT exams. Mahmood U; Horvat N; Horvat JV; Ryan D; Gao Y; Carollo G; DeOcampo R; Do RK; Katz S; Gerst S; Schmidtlein CR; Dauer L; Erdi Y; Mannelli L Eur J Radiol; 2018 May; 102():102-108. PubMed ID: 29685522 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]