267 related articles for article (PubMed ID: 20938067)
21. Fast analytical scatter estimation using graphics processing units.
Ingleby H; Lippuner J; Rickey DW; Li Y; Elbakri I
J Xray Sci Technol; 2015; 23(2):119-33. PubMed ID: 25882725
[TBL] [Abstract][Full Text] [Related]
22. Single-scan patient-specific scatter correction in computed tomography using peripheral detection of scatter and compressed sensing scatter retrieval.
Meng B; Lee H; Xing L; Fahimian BP
Med Phys; 2013 Jan; 40(1):011907. PubMed ID: 23298098
[TBL] [Abstract][Full Text] [Related]
23. Optimization of the geometry and speed of a moving blocker system for cone-beam computed tomography scatter correction.
Chen X; Ouyang L; Yan H; Jia X; Li B; Lyu Q; Zhang Y; Wang J
Med Phys; 2017 Sep; 44(9):e215-e229. PubMed ID: 28901608
[TBL] [Abstract][Full Text] [Related]
24. The effects of compensator and imaging geometry on the distribution of x-ray scatter in CBCT.
Bootsma GJ; Verhaegen F; Jaffray DA
Med Phys; 2011 Feb; 38(2):897-914. PubMed ID: 21452727
[TBL] [Abstract][Full Text] [Related]
25. Local filtration based scatter correction for cone-beam CT using primary modulation.
Zhu L
Med Phys; 2016 Nov; 43(11):6199. PubMed ID: 27806607
[TBL] [Abstract][Full Text] [Related]
26. A three-dimensional weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT under a circular source trajectory.
Tang X; Hsieh J; Hagiwara A; Nilsen RA; Thibault JB; Drapkin E
Phys Med Biol; 2005 Aug; 50(16):3889-905. PubMed ID: 16077234
[TBL] [Abstract][Full Text] [Related]
27. Patient-specific scatter correction in clinical cone beam computed tomography imaging made possible by the combination of Monte Carlo simulations and a ray tracing algorithm.
Thing RS; Bernchou U; Mainegra-Hing E; Brink C
Acta Oncol; 2013 Oct; 52(7):1477-83. PubMed ID: 23879648
[TBL] [Abstract][Full Text] [Related]
28. A GPU tool for efficient, accurate, and realistic simulation of cone beam CT projections.
Jia X; Yan H; Cervino L; Folkerts M; Jiang SB
Med Phys; 2012 Dec; 39(12):7368-78. PubMed ID: 23231286
[TBL] [Abstract][Full Text] [Related]
29. Efficient scatter distribution estimation and correction in CBCT using concurrent Monte Carlo fitting.
Bootsma GJ; Verhaegen F; Jaffray DA
Med Phys; 2015 Jan; 42(1):54-68. PubMed ID: 25563247
[TBL] [Abstract][Full Text] [Related]
30. Development and validation of MCNP4C-based Monte Carlo simulator for fan- and cone-beam x-ray CT.
Ay MR; Zaidi H
Phys Med Biol; 2005 Oct; 50(20):4863-85. PubMed ID: 16204878
[TBL] [Abstract][Full Text] [Related]
31. A practical cone-beam CT scatter correction method with optimized Monte Carlo simulations for image-guided radiation therapy.
Xu Y; Bai T; Yan H; Ouyang L; Pompos A; Wang J; Zhou L; Jiang SB; Jia X
Phys Med Biol; 2015 May; 60(9):3567-87. PubMed ID: 25860299
[TBL] [Abstract][Full Text] [Related]
32. An interprojection sensor fusion approach to estimate blocked projection signal in synchronized moving grid-based CBCT system.
Zhang H; Ren L; Kong V; Giles W; Zhang Y; Jin JY
Med Phys; 2016 Jan; 43(1):268. PubMed ID: 26745920
[TBL] [Abstract][Full Text] [Related]
33. A moving blocker system for cone-beam computed tomography scatter correction.
Ouyang L; Song K; Wang J
Med Phys; 2013 Jul; 40(7):071903. PubMed ID: 23822440
[TBL] [Abstract][Full Text] [Related]
34. Variance reduction techniques for fast Monte Carlo CBCT scatter correction calculations.
Mainegra-Hing E; Kawrakow I
Phys Med Biol; 2010 Aug; 55(16):4495-507. PubMed ID: 20668342
[TBL] [Abstract][Full Text] [Related]
35. Focused beam-stop array for the measurement of scatter in megavoltage portal and cone beam CT imaging.
Maltz JS; Gangadharan B; Vidal M; Paidi A; Bose S; Faddegon BA; Aubin M; Morin O; Pouliot J; Zheng Z; Svatos MM; Bani-Hashemi AR
Med Phys; 2008 Jun; 35(6):2452-62. PubMed ID: 18649478
[TBL] [Abstract][Full Text] [Related]
36. Motion-compensated iterative cone-beam CT image reconstruction with adapted blobs as basis functions.
Isola AA; Ziegler A; Koehler T; Niessen WJ; Grass M
Phys Med Biol; 2008 Dec; 53(23):6777-97. PubMed ID: 18997267
[TBL] [Abstract][Full Text] [Related]
37. A motion-compensated cone-beam CT using electrical impedance tomography imaging.
Pengpan T; Smith ND; Qiu W; Yao A; Mitchell CN; Soleimani M
Physiol Meas; 2011 Jan; 32(1):19-34. PubMed ID: 21098909
[TBL] [Abstract][Full Text] [Related]
38. Enhancement of in-plane spatial resolution in volumetric Computed Tomography with focal spot wobbling - overcoming the constraint on number of projection views per gantry rotation.
Tang X; Narayanan S; Hsieh J; Pack JD; Mcolash SM; Sainath P; Nilsen RA; Taha B
J Xray Sci Technol; 2010; 18(3):251-65. PubMed ID: 20714084
[TBL] [Abstract][Full Text] [Related]
39. Dose reduction for kilovotage cone-beam computed tomography in radiation therapy.
Wang J; Li T; Liang Z; Xing L
Phys Med Biol; 2008 Jun; 53(11):2897-909. PubMed ID: 18460749
[TBL] [Abstract][Full Text] [Related]
40. Accurate 3D data stitching in circular cone-beam micro-CT.
Ji C
J Xray Sci Technol; 2010; 18(2):99-110. PubMed ID: 20495238
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]