These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
116 related articles for article (PubMed ID: 2094318)
21. Neuromagnetic functional localization: principles, state of the art, and perspectives. Romani GL; Rossini P Brain Topogr; 1988; 1(1):5-21. PubMed ID: 3079264 [TBL] [Abstract][Full Text] [Related]
22. Comparison of performance of spherical and realistic head models in dipole localization from noisy EEG. Vanrumste B; Van Hoey G; Van de Walle R; D'Havé MR; Lemahieu IA; Boon PA Med Eng Phys; 2002 Jul; 24(6):403-18. PubMed ID: 12135649 [TBL] [Abstract][Full Text] [Related]
23. Preoperative localization of the central sulcus by dipole source analysis of early somatosensory evoked potentials and three-dimensional magnetic resonance imaging. Buchner H; Adams L; Knepper A; Rüger R; Laborde G; Gilsbach JM; Ludwig I; Reul J; Scherg M J Neurosurg; 1994 May; 80(5):849-56. PubMed ID: 8169625 [TBL] [Abstract][Full Text] [Related]
24. A ring-shaped distribution of dipoles as a source model of induced gamma-band activity. Tallon-Baudry C; Bertrand O; Pernier J Clin Neurophysiol; 1999 Apr; 110(4):660-5. PubMed ID: 10378735 [TBL] [Abstract][Full Text] [Related]
28. The inverse problem in MEG studies: an instrumental and analytical perspective. Romani GL Phys Med Biol; 1987 Jan; 32(1):23-31. PubMed ID: 3823134 [TBL] [Abstract][Full Text] [Related]
29. Improved dipole localization using local mesh refinement of realistic head geometries: an EEG simulation study. Yvert B; Bertrand O; Echallier JF; Pernier J Electroencephalogr Clin Neurophysiol; 1996 Jul; 99(1):79-89. PubMed ID: 8758973 [TBL] [Abstract][Full Text] [Related]
30. Ictal dipole source analysis based on a realistic scalp-skull-brain head model in localizing the epileptogenic zone. Mine S; Iwasa H; Kasagi Y; Yamaura A Neurosci Res; 2005 Apr; 51(4):453-61. PubMed ID: 15740808 [TBL] [Abstract][Full Text] [Related]
31. Theoretical evaluation of accuracy in position and size of brain activity obtained by near-infrared topography. Kawaguchi H; Hayashi T; Kato T; Okada E Phys Med Biol; 2004 Jun; 49(12):2753-65. PubMed ID: 15272686 [TBL] [Abstract][Full Text] [Related]
32. A finite-element reciprocity solution for EEG forward modeling with realistic individual head models. Ziegler E; Chellappa SL; Gaggioni G; Ly JQM; Vandewalle G; André E; Geuzaine C; Phillips C Neuroimage; 2014 Dec; 103():542-551. PubMed ID: 25204867 [TBL] [Abstract][Full Text] [Related]
33. Comparison between realistic and spherical approaches in EEG forward modelling. Meneghini F; Vatta F; Esposito F; Mininel S; Di Salle F Biomed Tech (Berl); 2010 Jun; 55(3):133-46. PubMed ID: 20178450 [TBL] [Abstract][Full Text] [Related]
34. Study of focal epilepsy by multichannel neuromagnetic measurements. Ricci GB; Romani GL; Salustri C; Pizzella V; Torrioli G; Buonomo S; Peresson M; Modena I Electroencephalogr Clin Neurophysiol; 1987 Apr; 66(4):358-68. PubMed ID: 2435515 [TBL] [Abstract][Full Text] [Related]
35. Surface-source modeling and estimation using biomagnetic measurements. Yetik IS; Nehorai A; Muravchik CH; Haueisen J; Eiselt M IEEE Trans Biomed Eng; 2006 Oct; 53(10):1872-82. PubMed ID: 17019850 [TBL] [Abstract][Full Text] [Related]
36. Effect of electrode density and measurement noise on the spatial resolution of cortical potential distribution. Ryynänen OR; Hyttinen JA; Laarne PH; Malmivuo JA IEEE Trans Biomed Eng; 2004 Sep; 51(9):1547-54. PubMed ID: 15376503 [TBL] [Abstract][Full Text] [Related]
37. Neuromagnetic localization of the late component of the contingent negative variation. Hultin L; Rossini P; Romani GL; Högstedt P; Tecchio F; Pizzella V Electroencephalogr Clin Neurophysiol; 1996 Jun; 98(6):435-48. PubMed ID: 8763503 [TBL] [Abstract][Full Text] [Related]
38. A comparison of the localization of spontaneous neuromagnetic activity in the frequency and time domains. Tesche C; Kajola M Electroencephalogr Clin Neurophysiol; 1993 Dec; 87(6):408-16. PubMed ID: 7508374 [TBL] [Abstract][Full Text] [Related]
39. [Spinal instrumentation, source of progress, but also revealing pitfalls]. Dubousset J Bull Acad Natl Med; 2003; 187(3):523-33. PubMed ID: 14556467 [TBL] [Abstract][Full Text] [Related]
40. Dipole modeling of epileptic spikes can be accurate or misleading. Kobayashi K; Yoshinaga H; Ohtsuka Y; Gotman J Epilepsia; 2005 Mar; 46(3):397-408. PubMed ID: 15730537 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]