These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
139 related articles for article (PubMed ID: 2094658)
1. Periotest method as a measure of osseointegrated oral implant stability. Olivé J; Aparicio C Int J Oral Maxillofac Implants; 1990; 5(4):390-400. PubMed ID: 2094658 [TBL] [Abstract][Full Text] [Related]
2. The use of the Periotest value as the initial success criteria of an implant: 8-year report. Aparicio C Int J Periodontics Restorative Dent; 1997 Apr; 17(2):150-61. PubMed ID: 9497709 [TBL] [Abstract][Full Text] [Related]
3. Periotest: an objective clinical diagnosis of bone apposition toward implants. Teerlinck J; Quirynen M; Darius P; van Steenberghe D Int J Oral Maxillofac Implants; 1991; 6(1):55-61. PubMed ID: 1843494 [TBL] [Abstract][Full Text] [Related]
4. Mobility assessment with the Periotest system in relation to histologic findings of oral implants. Isidor F Int J Oral Maxillofac Implants; 1998; 13(3):377-83. PubMed ID: 9638008 [TBL] [Abstract][Full Text] [Related]
5. A prospective study to assess osseointegration of dental endosseous implants with the Periotest instrument. Drago CJ Int J Oral Maxillofac Implants; 2000; 15(3):389-95. PubMed ID: 10874804 [TBL] [Abstract][Full Text] [Related]
6. Bone density: its influence on implant stability after uncovering. Morris HE; Ochi S; Crum P; Orenstein I; Plezia R J Oral Implantol; 2003; 29(6):263-9. PubMed ID: 14719574 [TBL] [Abstract][Full Text] [Related]
7. Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability. Meredith N; Friberg B; Sennerby L; Aparicio C Int J Prosthodont; 1998; 11(3):269-75. PubMed ID: 9728122 [TBL] [Abstract][Full Text] [Related]
8. Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: comparison of both techniques in a clinical trial. Zix J; Hug S; Kessler-Liechti G; Mericske-Stern R Int J Oral Maxillofac Implants; 2008; 23(3):525-30. PubMed ID: 18700378 [TBL] [Abstract][Full Text] [Related]
9. Effect of occlusal wear on bone loss and Periotest value of dental implants. Engel E; Gomez-Roman G; Axmann-Krcmar D Int J Prosthodont; 2001; 14(5):444-50. PubMed ID: 12066640 [TBL] [Abstract][Full Text] [Related]
10. [The use of the Periotest method for the clinical assessment of the efficacy of dental implantation]. Matveeva AI; Gvetadze RSh; Loginov VE Stomatologiia (Mosk); 1999; 78(3):28-9. PubMed ID: 10368602 [TBL] [Abstract][Full Text] [Related]
11. The Periotest method for determining implant success. Van Scotter DE; Wilson CJ J Oral Implantol; 1991; 17(4):410-3. PubMed ID: 1813649 [TBL] [Abstract][Full Text] [Related]
12. A comparative study of two noninvasive techniques to evaluate implant stability: Periotest and Osstell Mentor. Oh JS; Kim SG; Lim SC; Ong JL Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2009 Apr; 107(4):513-8. PubMed ID: 19095473 [TBL] [Abstract][Full Text] [Related]
13. Evaluation of the implant master cast by means of the Periotest method. May KB; Curtis A; Wang RF Implant Dent; 1999; 8(2):133-40. PubMed ID: 10635155 [TBL] [Abstract][Full Text] [Related]
14. Assessment of implant stability as a prognostic determinant. Meredith N Int J Prosthodont; 1998; 11(5):491-501. PubMed ID: 9922740 [TBL] [Abstract][Full Text] [Related]
15. Mechanical state assessment of the implant-bone continuum: a better understanding of the Periotest method. Tricio J; Laohapand P; van Steenberghe D; Quirynen M; Naert I Int J Oral Maxillofac Implants; 1995; 10(1):43-9. PubMed ID: 7615316 [TBL] [Abstract][Full Text] [Related]
16. Periotest to monitor osseointegration and to check the occlusion in oral implantology. Schulte W; Lukas D J Oral Implantol; 1993; 19(1):23-32. PubMed ID: 8246291 [TBL] [Abstract][Full Text] [Related]