85 related articles for article (PubMed ID: 20947409)
41. In vitro evaluation of endovascular stents to assess suitability for endovascular graft fixation.
Andrews SM; Anson AW; Greenhalgh RM; Nott DM
Eur J Vasc Endovasc Surg; 1995 May; 9(4):403-7. PubMed ID: 7633984
[TBL] [Abstract][Full Text] [Related]
42. Endotension as a result of pressure transmission through the graft following endovascular aneurysm repair--an in vitro study.
Gawenda M; Jaschke G; Winter S; Wassmer G; Brunkwall J
Eur J Vasc Endovasc Surg; 2003 Nov; 26(5):501-5. PubMed ID: 14532877
[TBL] [Abstract][Full Text] [Related]
43. The effect of stent graft oversizing on radial forces considering nitinol wire behavior and vessel characteristics.
Senf B; von Sachsen S; Neugebauer R; Drossel WG; Florek HJ; Mohr FW; Etz CD
Med Eng Phys; 2014 Nov; 36(11):1480-6. PubMed ID: 25183045
[TBL] [Abstract][Full Text] [Related]
44. Fluid structure interaction simulation in three-layered aortic aneurysm model under pulsatile flow: comparison of wrapping and stenting.
Gao F; Ueda H; Gang L; Okada H
J Biomech; 2013 Apr; 46(7):1335-42. PubMed ID: 23477789
[TBL] [Abstract][Full Text] [Related]
45. Fluoroscopic Roentgen stereophotogrammetric analysis (FRSA) to study three-dimensional stent graft dynamics.
Koning OH; Kaptein BL; van der Vijver R; Dias NV; Malina M; Schalij MJ; Valstar ER; van Bockel JH
J Vasc Surg; 2009 Aug; 50(2):407-12. PubMed ID: 19631876
[TBL] [Abstract][Full Text] [Related]
46. Flow-independent dynamics in aneurysm (FIDA): pressure measurements following partial and complete flow impairment in experimental aneurysm model.
Majidi S; Watanabe M; Chaudhry SA; Qureshi AI
J Vasc Interv Neurol; 2014 Sep; 7(3):41-5. PubMed ID: 25298859
[TBL] [Abstract][Full Text] [Related]
47. Experimental measurement and mathematical modeling of pulsatile forces on a symmetric, bifurcated endoluminal stent graft model.
Liffman K; Sutalo ID; Bui A; Lawrence-Brown MM; Semmens JB
Vascular; 2009; 17(4):201-9. PubMed ID: 19698300
[TBL] [Abstract][Full Text] [Related]
48. Surgical stent planning: simulation parameter study for models based on DICOM standards.
Scherer S; Treichel T; Ritter N; Triebel G; Drossel WG; Burgert O
Int J Comput Assist Radiol Surg; 2011 May; 6(3):319-27. PubMed ID: 20652645
[TBL] [Abstract][Full Text] [Related]
49. Are self-expanding stents superior to balloon-expanded in dilating aortas? An experimental study in pigs.
Mangell P; Malina M; Vogt K; Lindh M; Schroeder T; Risberg B; Brunkwall J; Länne T
Eur J Vasc Endovasc Surg; 1996 Oct; 12(3):287-94. PubMed ID: 8896470
[TBL] [Abstract][Full Text] [Related]
50. The Effects That Cardiac Motion has on Coronary Hemodynamics and Catheter Trackability Forces for the Treatment of Coronary Artery Disease: An In Vitro Assessment.
Morris L; Fahy P; Stefanov F; Finn R
Cardiovasc Eng Technol; 2015 Dec; 6(4):430-49. PubMed ID: 26577477
[TBL] [Abstract][Full Text] [Related]
51.
Zhuravleva IY; Timchenko TP; Vladimirov SV; Lyashenko MM; Kuznetsova EV; Chernyavskiy AM
Sovrem Tekhnologii Med; 2021; 13(1):17-25. PubMed ID: 34513062
[TBL] [Abstract][Full Text] [Related]
52. Evaluating Changes in Pulsatile Flow With Endovascular Stents in an In Vitro Blood Vessel Model: Potential Implications for the Future Management of Neurovascular Compression Syndromes.
Siddiqi I; Brazdzionis J; Hough JM; Reier L; Marino M; Ko K; Schiraldi M; Cortez V; Miulli DE
Cureus; 2024 May; 16(5):e59811. PubMed ID: 38846216
[TBL] [Abstract][Full Text] [Related]
53. Investigation of mechanical behaviors and improved design of V-shaped braid stents.
Liu X; Liu G; Ye P; Luo Q; Chang Z
Proc Inst Mech Eng H; 2022 Feb; ():9544119221076946. PubMed ID: 35102787
[TBL] [Abstract][Full Text] [Related]
54. Fast and Accurate Computation of the Displacement Force of Stent Grafts after Endovascular Aneurysm Repair.
Qing M; Liu Z; Zheng T
Bioengineering (Basel); 2022 Sep; 9(9):. PubMed ID: 36134992
[No Abstract] [Full Text] [Related]
55. Influence of blood shear-thinning behaviour on flow dynamics in abdominal aortic aneurysm in vitro compliant model.
Deplano V; Bailly L; Bertrand E
Comput Methods Biomech Biomed Engin; 2012; 15 Suppl 1():49-52. PubMed ID: 23009420
[No Abstract] [Full Text] [Related]
56. Ex Vivo Comparison of the Elastic Properties of Vascular Substitutes Used for Pulmonary Artery Replacement.
Hireche K; Canaud L; Peyron PA; Sakhri L; Serres I; Kamel S; Lounes Y; Gandet T; Alric P
J Surg Res; 2024 Mar; 295():222-230. PubMed ID: 38039727
[TBL] [Abstract][Full Text] [Related]
57. Development of an ex vivo aneurysm model for vascular device testing.
Vanerio N; Stijnen M; De Mol BAJM; Kock LM
ALTEX; 2020; 37(1):110-120. PubMed ID: 31686112
[TBL] [Abstract][Full Text] [Related]
58. Safety evaluation of laparoscopically applied clips.
Papaioannou T; Daykhovsky L; Grundfest WS
J Laparoendosc Surg; 1996 Apr; 6(2):99-107. PubMed ID: 8735047
[TBL] [Abstract][Full Text] [Related]
59. Quantitation of abdominal aortic wall dynamics in man by gradient echo NMR imaging.
Lanzer P; McKibbin W; Bohning D; Pohost G
Magn Reson Med; 1990 Mar; 13(3):407-15. PubMed ID: 2325541
[TBL] [Abstract][Full Text] [Related]
60. Conceptual Framework Development for a Double-Walled Aortic Stent-Graft to Manage Blood Pressure.
Kizilski SB; Amili O; Coletti F; Faizer R; Barocas VH
J Med Device; 2020 Sep; 14(3):031005. PubMed ID: 32983314
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]