These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

194 related articles for article (PubMed ID: 2095023)

  • 1. Inadequacy of a polyester (Mersilene) suture for the reduction of astigmatism after penetrating keratoplasty.
    Bertram BA; Drews C; Gemmill M; Guell J; Murad M; Waring GO
    Trans Am Ophthalmol Soc; 1990; 88():237-49; discussion 249-54. PubMed ID: 2095023
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Complications of Mersilene sutures in penetrating keratoplasty.
    Bertram BA; Drews-Botsch C; Gemmill M; Guell J; Murad M; Waring GO
    Refract Corneal Surg; 1992; 8(4):296-305. PubMed ID: 1390410
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Mersilene (polyester), a new suture for penetrating keratoplasty.
    Ramselaar JA; Beekhuis WH; Rijneveld WJ; van Andel MV; Dijk F; Jongebloed WL
    Doc Ophthalmol; 1992; 82(1-2):89-101. PubMed ID: 1305032
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Astigmatism after mersilene and nylon suture use for penetrating keratoplasty.
    Landau D; Siganos CS; Mechoulam H; Solomon A; Frucht-Pery J
    Cornea; 2006 Jul; 25(6):691-4. PubMed ID: 17077662
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of complication rates and postoperative astigmatism between nylon and mersilene sutures for corneal transplants in patients with Fuchs endothelial dystrophy.
    Bartels MC; van Rooij J; Geerards AJ; Mulder PG; Remeijer L
    Cornea; 2006 Jun; 25(5):533-9. PubMed ID: 16783141
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Combined interrupted and continuous versus single continuous adjustable suturing in penetrating keratoplasty: a prospective, randomized study of induced astigmatism during the first postoperative year.
    Karabatsas CH; Cook SD; Figueiredo FC; Diamond JP; Easty DL
    Ophthalmology; 1998 Nov; 105(11):1991-8. PubMed ID: 9818595
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mersilene sutures for corneal surgery.
    Frucht-Pery J
    Ophthalmic Surg; 1995; 26(2):117-20. PubMed ID: 7596537
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Astigmatism following cataract surgery: comparison following wound closure with nylon suture and Mersilene].
    Bigar F
    Klin Monbl Augenheilkd; 1990 May; 196(5):314-5. PubMed ID: 2195225
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Postkeratoplasty astigmatism with single running suture or interrupted sutures.
    Filatov V; Steinert RF; Talamo JH
    Am J Ophthalmol; 1993 Jun; 115(6):715-21. PubMed ID: 8506906
    [TBL] [Abstract][Full Text] [Related]  

  • 10. 11-0 mersilene as running suture for penetrating keratoplasty.
    Frueh BE; Brown SI; Feldman ST
    Am J Ophthalmol; 1992 Dec; 114(6):675-9. PubMed ID: 1463036
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of suture-in and suture-out postkeratoplasty astigmatism with single running suture or combined running and interrupted sutures.
    Filatov V; Alexandrakis G; Talamo JH; Steinert RF
    Am J Ophthalmol; 1996 Nov; 122(5):696-700. PubMed ID: 8909210
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Astigmatism shift after extracapsular surgery: Mersilene versus nylon.
    Drews RC
    Int Ophthalmol; 1989 May; 13(3):209-10. PubMed ID: 2793315
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A comparison of two selective interrupted suture removal techniques for control of post keratoplasty astigmatism.
    Forster RK
    Trans Am Ophthalmol Soc; 1997; 95():193-214; discussion 214-20. PubMed ID: 9440170
    [TBL] [Abstract][Full Text] [Related]  

  • 14. 11-0 Mersilene alone as a single running suture in corneal grafts.
    Kalyansundaram TS; Bearn MA
    Eye (Lond); 2001 Jun; 15(Pt 3):288-91. PubMed ID: 11450722
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Astigmatism after cataract surgery: nylon versus Mersilene.
    Drews RC
    Ophthalmic Surg; 1989 Oct; 20(10):695-6. PubMed ID: 2616109
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Changes in keratometric astigmatism after suture removal more than one year after penetrating keratoplasty.
    Mader TH; Yuan R; Lynn MJ; Stulting RD; Wilson LA; Waring GO
    Ophthalmology; 1993 Jan; 100(1):119-26; discussion 127. PubMed ID: 8433816
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Running nylon suture dissolution after penetrating keratoplasty.
    Frueh BE; Feldman ST; Feldman RM; Sossi NP; Frucht-Pery J; Brown SI
    Am J Ophthalmol; 1992 Apr; 113(4):406-11. PubMed ID: 1558114
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The efficacy of a single continuous nylon suture for control of post keratoplasty astigmatism.
    Van Meter W
    Trans Am Ophthalmol Soc; 1996; 94():1157-80. PubMed ID: 8981721
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [The unsolved problem of transplant astigmatism].
    Bigar F; Uffer S
    Klin Monbl Augenheilkd; 1992 May; 200(5):401-3. PubMed ID: 1535401
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Shortterm and longterm visual and astigmatic results of an opposing 10-0 nylon double running suture technique for penetrating keratoplasty.
    Dolorico AM; Tayyani R; Ong HV; Gaster RN
    J Am Coll Surg; 2003 Dec; 197(6):991-9. PubMed ID: 14644288
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.