These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
8. Combined atrial and ventricular antitachycardia pacing as a novel method of rhythm discrimination: the Dynamic Discrimination Download Study. Saba S; Volosin K; Yee R; Swerdlow C; Brown M; Circulation; 2010 Feb; 121(4):487-97. PubMed ID: 20083678 [TBL] [Abstract][Full Text] [Related]
9. Performance of a new single-chamber ICD algorithm: discrimination of supraventricular and ventricular tachycardia based on vector timing and correlation. Corbisiero R; Lee MA; Nabert DR; Coman JA; Breiter DJ; Schwartz M; McKittrick E; Zhang Y Europace; 2006 Dec; 8(12):1057-61. PubMed ID: 17105781 [TBL] [Abstract][Full Text] [Related]
10. Importance of the atrial channel for ventricular arrhythmia therapy in the dual chamber implantable cardioverter defibrillator. Dijkman B; Wellens HJ J Cardiovasc Electrophysiol; 2000 Dec; 11(12):1309-19. PubMed ID: 11196552 [TBL] [Abstract][Full Text] [Related]
11. Simultaneous atrial and ventricular anti-tachycardia pacing as a novel method of rhythm discrimination. Saba S; Baker L; Ganz L; Barrington W; Jain S; Ngwu O; Christensen J; Brown M J Cardiovasc Electrophysiol; 2006 Jul; 17(7):695-701. PubMed ID: 16836661 [TBL] [Abstract][Full Text] [Related]
12. Prevention of inappropriate shocks in ICD recipients: a review of 10,000 tachycardia episodes. Anselme F; Mletzko R; Bowes R; Mabo P; Sadoul N; Schoels W; Seidl K; Schwab J; Iscolo N; Nitzsché R Pacing Clin Electrophysiol; 2007 Jan; 30 Suppl 1():S128-33. PubMed ID: 17302688 [TBL] [Abstract][Full Text] [Related]
13. Performance of a dual-chamber implantable defibrillator algorithm for discrimination of ventricular from supraventricular tachycardia. Kouakam C; Kacet S; Hazard JR; Ferraci A; Mansour H; Defaye P; Davy JM; Lambiez M; Europace; 2004 Jan; 6(1):32-42. PubMed ID: 14697724 [TBL] [Abstract][Full Text] [Related]
14. Innovative P-wave detection for discrimination between ventricular and supraventricular tachycardia in single-chamber ICDs: is the P-wave invisible during tachycardia? Xiong WW; Karam PY; Marsh JD; Varma N; Verdino RJ; Paydak H Europace; 2013 Jun; 15(6):827-34. PubMed ID: 23512155 [TBL] [Abstract][Full Text] [Related]
15. Prevention of inappropriate therapy in implantable cardioverter-defibrillators: results of a prospective, randomized study of tachyarrhythmia detection algorithms. Theuns DA; Klootwijk AP; Goedhart DM; Jordaens LJ J Am Coll Cardiol; 2004 Dec; 44(12):2362-7. PubMed ID: 15607399 [TBL] [Abstract][Full Text] [Related]
17. The 1+1 trial: a prospective trial of a dual- versus a single-chamber implantable defibrillator in patients with slow ventricular tachycardias. Bänsch D; Steffgen F; Grönefeld G; Wolpert C; Böcker D; Mletzko RU; Schöls W; Seidl K; Piel M; Ouyang F; Hohnloser SH; Kuck KH Circulation; 2004 Aug; 110(9):1022-9. PubMed ID: 15326069 [TBL] [Abstract][Full Text] [Related]
18. A new method to investigate the response to the morphology discrimination algorithm in patients with ICD. Sinha AM; Schimpf R; Schwab JO; Birkenhauer F; Breithardt OA; Brachmann J; Schibgilla V; Hanrath P; Stellbrink C Int J Cardiol; 2007 Jan; 114(3):323-31. PubMed ID: 16740324 [TBL] [Abstract][Full Text] [Related]
19. Evaluation of morphology discrimination for ventricular tachycardia diagnosis in implantable cardioverter-defibrillators. Theuns DA; Rivero-Ayerza M; Goedhart DM; van der Perk R; Jordaens LJ Heart Rhythm; 2006 Nov; 3(11):1332-8. PubMed ID: 17074640 [TBL] [Abstract][Full Text] [Related]
20. An overview of the fifth-generation implantable cardioverter defibrillator. Tanaka S Ann Thorac Cardiovasc Surg; 1998 Dec; 4(6):303-11. PubMed ID: 9914457 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]