99 related articles for article (PubMed ID: 2095141)

  • 1. A comparative study of the shear stress induced in the leakage backflow produced by four types of heart valve prostheses.
    Haggag YA
    Proc Inst Mech Eng H; 1990; 204(2):111-4. PubMed ID: 2095141
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparative study of the amount of backflow produced by four types of aortic valve prostheses.
    Sabbah HN; Stein PD
    J Biomech Eng; 1984 Feb; 106(1):66-71. PubMed ID: 6727316
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A numerical analysis of the backflow between the leaflets of a St Jude Medical cardiac valve prosthesis.
    Reif TH
    J Biomech; 1991; 24(8):733-41. PubMed ID: 1918096
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of heart rate on the hemodynamics of bileaflet mechanical heart valves' prostheses (St. Jude Medical) in the aortic position and in the opening phase: A computational study.
    Jahandardoost M; Fradet G; Mohammadi H
    Proc Inst Mech Eng H; 2016 Mar; 230(3):175-90. PubMed ID: 26786673
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In-vivo turbulent stresses of bileaflet prosthesis leakage jets.
    Travis BR; Christensen TD; Smerup M; Olsen MS; Hasenkam JM; Nygaard H
    J Heart Valve Dis; 2005 Sep; 14(5):644-56. PubMed ID: 16245504
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Hemodynamic study of the elliptic St. Jude Medical valve: A computational study.
    Jahandardoost M; Fradet G; Mohammadi H
    Proc Inst Mech Eng H; 2016 Feb; 230(2):85-96. PubMed ID: 26783246
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An in vitro investigation of the retrograde flow fields of two bileaflet mechanical heart valves.
    Ellis JT; Healy TM; Fontaine AA; Weston MW; Jarret CA; Saxena R; Yoganathan AP
    J Heart Valve Dis; 1996 Nov; 5(6):600-6. PubMed ID: 8953437
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reynolds shear stress for textile prosthetic heart valves in relation to fabric design.
    Bark DL; Yousefi A; Forleo M; Vaesken A; Heim F; Dasi LP
    J Mech Behav Biomed Mater; 2016 Jul; 60():280-287. PubMed ID: 26919564
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Numerical simulation of instantaneous backflow through central clearance of bileaflet mechanical heart valves at closure: shear stress and pressure fields within clearance.
    Lee CS; Chandran KB
    Med Biol Eng Comput; 1995 May; 33(3):257-63. PubMed ID: 7475360
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of oscillation on elevating shear stresses.
    Sakhaeimanesh AA
    J Med Eng Technol; 2008; 32(6):434-9. PubMed ID: 19005961
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In vitro pulsatile flow measurements in the vicinity of mechanical heart valves in the mitral flow chamber.
    Woo YR; Yoganathan AP
    Life Support Syst; 1986; 4(2):115-39. PubMed ID: 2943945
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Importance of shear in prosthetic valve closure dynamics.
    Scotten LN; Siegel R
    J Heart Valve Dis; 2011 Nov; 20(6):664-72. PubMed ID: 22655497
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Shear stress related blood damage along the cusp of a tri-leaflet prosthetic valve.
    Einav S; Reul H; Rau G; Elad D
    Int J Artif Organs; 1991 Nov; 14(11):716-20. PubMed ID: 1757159
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Leakage of mechanical heart valve prostheses of Björk-Shiley type: in vitro investigations using Newtonian fluids.
    Wendt MO; Pohl M; Lerche D
    J Biomed Eng; 1991 Mar; 13(2):126-32. PubMed ID: 2033948
    [TBL] [Abstract][Full Text] [Related]  

  • 15. On the hemodynamics of several prosthetic heart valves: in vitro study.
    Modi VJ; Akutsu T
    Monogr Atheroscler; 1990; 15():125-37. PubMed ID: 2296238
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Influence of mimic cardiac rate on hydrodynamics of different mechanical prosthetic cardiac valves in vitro.
    Chu YP; Cheng JL; Chen RK; Fan YB; Pu F
    Chin Med Sci J; 2005 Jun; 20(2):138-41. PubMed ID: 16075758
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In vitro pulsatile flow hemodynamics of five mechanical aortic heart valve prostheses.
    Walker PG; Yoganathan AP
    Eur J Cardiothorac Surg; 1992; 6 Suppl 1():S113-23. PubMed ID: 1389270
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Leakage flow at mechanical heart valve prostheses: improved washout or increased blood damage?
    Steegers A; Paul R; Reul H; Rau G
    J Heart Valve Dis; 1999 May; 8(3):312-23. PubMed ID: 10399668
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Causes and formation of cavitation in mechanical heart valves.
    Graf T; Reul H; Detlefs C; Wilmes R; Rau G
    J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S49-64. PubMed ID: 8061870
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Can regurgitant flow damage the left atrial endothelium in patients with prosthetic mechanical heart valves?
    Milo S; Zarandi M; Gutfinger C; Gharib M
    J Heart Valve Dis; 2005 May; 14(3):344-52. PubMed ID: 15974529
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]