These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 20951626)

  • 1. Fluid load support and contact mechanics of hemiarthroplasty in the natural hip joint.
    Pawaskar SS; Ingham E; Fisher J; Jin Z
    Med Eng Phys; 2011 Jan; 33(1):96-105. PubMed ID: 20951626
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hemiarthroplasty of hip joint: An experimental validation using porcine acetabulum.
    Pawaskar SS; Grosland NM; Ingham E; Fisher J; Jin Z
    J Biomech; 2011 May; 44(8):1536-42. PubMed ID: 21439570
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Robust and general method for determining surface fluid flow boundary conditions in articular cartilage contact mechanics modeling.
    Pawaskar SS; Fisher J; Jin Z
    J Biomech Eng; 2010 Mar; 132(3):031001. PubMed ID: 20459189
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An investigation of the effect of conformity of knee hemiarthroplasty designs on contact stress, friction and degeneration of articular cartilage: a tribological study.
    McCann L; Ingham E; Jin Z; Fisher J
    J Biomech; 2009 Jun; 42(9):1326-31. PubMed ID: 19380137
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biphasic surface amorphous layer lubrication of articular cartilage.
    Graindorge S; Ferrandez W; Jin Z; Ingham E; Grant C; Twigg P; Fisher J
    Med Eng Phys; 2005 Dec; 27(10):836-44. PubMed ID: 16046176
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dependence of nanoscale friction and adhesion properties of articular cartilage on contact load.
    Chan SM; Neu CP; Komvopoulos K; Reddi AH
    J Biomech; 2011 Apr; 44(7):1340-5. PubMed ID: 21316681
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of shear stress on articular chondrocyte metabolism.
    Lane Smith R; Trindade MC; Ikenoue T; Mohtai M; Das P; Carter DR; Goodman SB; Schurman DJ
    Biorheology; 2000; 37(1-2):95-107. PubMed ID: 10912182
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Congruency effects on load bearing in diarthrodial joints.
    Adeeb SM; Sayed Ahmed EY; Matyas J; Hart DA; Frank CB; Shrive NG
    Comput Methods Biomech Biomed Engin; 2004 Jun; 7(3):147-57. PubMed ID: 15512758
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].
    Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of clearance on cartilage tribology in hip hemi-arthroplasty.
    Lizhang J; Taylor SD; Jin Z; Fisher J; Williams S
    Proc Inst Mech Eng H; 2013 Dec; 227(12):1284-91. PubMed ID: 24043224
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Articular cartilage friction increases in hip joints after the removal of acetabular labrum.
    Song Y; Ito H; Kourtis L; Safran MR; Carter DR; Giori NJ
    J Biomech; 2012 Feb; 45(3):524-30. PubMed ID: 22176711
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The low permeability of healthy meniscus and labrum limit articular cartilage consolidation and maintain fluid load support in the knee and hip.
    Haemer JM; Carter DR; Giori NJ
    J Biomech; 2012 May; 45(8):1450-6. PubMed ID: 22391467
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effects of impingement and dysplasia on stress distributions in the hip joint during sitting and walking: a finite element analysis.
    Chegini S; Beck M; Ferguson SJ
    J Orthop Res; 2009 Feb; 27(2):195-201. PubMed ID: 18752280
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The thixotropic effect of the synovial fluid in squeeze-film lubrication of the human hip joint.
    Hlavácek M
    Biorheology; 2001; 38(4):319-34. PubMed ID: 11673647
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of 3D physiological loading and motion on elastohydrodynamic lubrication of metal-on-metal total hip replacements.
    Gao L; Wang F; Yang P; Jin Z
    Med Eng Phys; 2009 Jul; 31(6):720-9. PubMed ID: 19269879
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Loss in mechanical contact of cementless acetabular prostheses due to post-operative weight bearing: a biomechanical model.
    Bellini CM; Galbusera F; Ceroni RG; Raimondi MT
    Med Eng Phys; 2007 Mar; 29(2):175-81. PubMed ID: 16569508
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of swing phase load on metal-on-metal hip lubrication, friction and wear.
    Williams S; Jalali-Vahid D; Brockett C; Jin Z; Stone MH; Ingham E; Fisher J
    J Biomech; 2006; 39(12):2274-81. PubMed ID: 16143337
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The role of lubricant entrapment at biological interfaces: reduction of friction and adhesion in articular cartilage.
    Chan SM; Neu CP; Komvopoulos K; Reddi AH
    J Biomech; 2011 Jul; 44(11):2015-20. PubMed ID: 21679953
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Three-dimensional dynamic hip contact area and pressure distribution during activities of daily living.
    Yoshida H; Faust A; Wilckens J; Kitagawa M; Fetto J; Chao EY
    J Biomech; 2006; 39(11):1996-2004. PubMed ID: 16120442
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Lubrication and cartilage.
    Wright V; Dowson D
    J Anat; 1976 Feb; 121(Pt 1):107-18. PubMed ID: 3490
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.