129 related articles for article (PubMed ID: 2095530)
1. Analysis of the swing phase dynamics and muscular effort of the above-knee amputee for varying prosthetic shank loads.
Hale SA
Prosthet Orthot Int; 1990 Dec; 14(3):125-35. PubMed ID: 2095530
[TBL] [Abstract][Full Text] [Related]
2. Effect of prosthetic mass on swing phase work during above-knee amputee ambulation.
Gitter A; Czerniecki J; Meinders M
Am J Phys Med Rehabil; 1997; 76(2):114-21. PubMed ID: 9129517
[TBL] [Abstract][Full Text] [Related]
3. Long-distance walking effects on trans-tibial amputees compensatory gait patterns and implications on prosthetic designs and training.
Yeung LF; Leung AK; Zhang M; Lee WC
Gait Posture; 2012 Feb; 35(2):328-33. PubMed ID: 22055554
[TBL] [Abstract][Full Text] [Related]
4. The strategies to regulate and to modulate the propulsive forces during gait initiation in lower limb amputees.
Michel V; Chong RK
Exp Brain Res; 2004 Oct; 158(3):356-65. PubMed ID: 15167976
[TBL] [Abstract][Full Text] [Related]
5. Effects of mass and momentum of inertia alternation on individual muscle forces during swing phase of transtibial amputee gait.
Dabiri Y; Najarian S; Eslami MR; Zahedi S; Moser D; Shirzad E; Allami M
Kobe J Med Sci; 2010 Sep; 56(3):E92-7. PubMed ID: 21063155
[TBL] [Abstract][Full Text] [Related]
6. Effect of prosthetic ankle units on the gait of persons with bilateral trans-femoral amputations.
McNealy LL; Gard SA
Prosthet Orthot Int; 2008 Mar; 32(1):111-26. PubMed ID: 18330810
[TBL] [Abstract][Full Text] [Related]
7. Contributions to the understanding of gait control.
Simonsen EB
Dan Med J; 2014 Apr; 61(4):B4823. PubMed ID: 24814597
[TBL] [Abstract][Full Text] [Related]
8. Kinematic and kinetic comparisons of transfemoral amputee gait using C-Leg and Mauch SNS prosthetic knees.
Segal AD; Orendurff MS; Klute GK; McDowell ML; Pecoraro JA; Shofer J; Czerniecki JM
J Rehabil Res Dev; 2006; 43(7):857-70. PubMed ID: 17436172
[TBL] [Abstract][Full Text] [Related]
9. Altered kinetic strategy for the control of swing limb elevation over obstacles in unilateral below-knee amputee gait.
Hill SW; Patla AE; Ishac MG; Adkin AL; Supan TJ; Barth DG
J Biomech; 1999 May; 32(5):545-9. PubMed ID: 10327009
[TBL] [Abstract][Full Text] [Related]
10. Design optimization of an above-knee prosthesis based on the kinematics of gait.
Pejhan S; Farahmand F; Parnianpour M
Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():4274-7. PubMed ID: 19163657
[TBL] [Abstract][Full Text] [Related]
11. Sprint kinematics of athletes with lower-limb amputations.
Buckley JG
Arch Phys Med Rehabil; 1999 May; 80(5):501-8. PubMed ID: 10326911
[TBL] [Abstract][Full Text] [Related]
12. Performance assessment of the Terry Fox jogging prosthesis for above-knee amputees.
DiAngelo DJ; Winter DA; Ghista DN; Newcombe WR
J Biomech; 1989; 22(6-7):543-58. PubMed ID: 2808440
[TBL] [Abstract][Full Text] [Related]
13. Swing phase control with knee friction in juvenile amputees.
Hicks R; Tashman S; Cary JM; Altman RF; Gage JR
J Orthop Res; 1985; 3(2):198-201. PubMed ID: 3998896
[TBL] [Abstract][Full Text] [Related]
14. Segment velocities in normal and transtibial amputees: prosthetic design implications.
Rao SS; Boyd LA; Mulroy SJ; Bontrager EL; Gronley JK; Perry J
IEEE Trans Rehabil Eng; 1998 Jun; 6(2):219-26. PubMed ID: 9631330
[TBL] [Abstract][Full Text] [Related]
15. Walking symmetry and energy cost in persons with unilateral transtibial amputations: matching prosthetic and intact limb inertial properties.
Mattes SJ; Martin PE; Royer TD
Arch Phys Med Rehabil; 2000 May; 81(5):561-8. PubMed ID: 10807092
[TBL] [Abstract][Full Text] [Related]
16. Co-contraction patterns of trans-tibial amputee ankle and knee musculature during gait.
Seyedali M; Czerniecki JM; Morgenroth DC; Hahn ME
J Neuroeng Rehabil; 2012 May; 9():29. PubMed ID: 22640660
[TBL] [Abstract][Full Text] [Related]
17. [Significance of static prosthesis alignment for standing and walking of patients with lower limb amputation].
Blumentritt S; Schmalz T; Jarasch R
Orthopade; 2001 Mar; 30(3):161-8. PubMed ID: 11501007
[TBL] [Abstract][Full Text] [Related]
18. Does a microprocessor-controlled prosthetic knee affect stair ascent strategies in persons with transfemoral amputation?
Aldridge Whitehead JM; Wolf EJ; Scoville CR; Wilken JM
Clin Orthop Relat Res; 2014 Oct; 472(10):3093-101. PubMed ID: 24515402
[TBL] [Abstract][Full Text] [Related]
19. Planar covariation of elevation angles in prosthetic gait.
Leurs F; Bengoetxea A; Cebolla AM; De Saedeleer C; Dan B; Cheron G
Gait Posture; 2012 Apr; 35(4):647-52. PubMed ID: 22257927
[TBL] [Abstract][Full Text] [Related]
20. The influence of energy storage and return foot stiffness on walking mechanics and muscle activity in below-knee amputees.
Fey NP; Klute GK; Neptune RR
Clin Biomech (Bristol, Avon); 2011 Dec; 26(10):1025-32. PubMed ID: 21777999
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]