These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
92 related articles for article (PubMed ID: 20960577)
1. Uniform prostate imaging and spectroscopy at 7 T: comparison between a microstrip array and an endorectal coil. van den Bergen B; Klomp DW; Raaijmakers AJ; de Castro CA; Boer VO; Kroeze H; Luijten PR; Lagendijk JJ; van den Berg CA NMR Biomed; 2011 May; 24(4):358-65. PubMed ID: 20960577 [TBL] [Abstract][Full Text] [Related]
2. High-field MRSI of the prostate using a transmit/receive endorectal coil and gradient modulated adiabatic localization. Near J; Romagnoli C; Curtis AT; Klassen LM; Izawa J; Chin J; Bartha R J Magn Reson Imaging; 2009 Aug; 30(2):335-43. PubMed ID: 19629986 [TBL] [Abstract][Full Text] [Related]
3. A multitransmit external body array combined with a Philips BWJ; van Uden MJ; Rietsch SHG; Orzada S; Scheenen TWJ Med Phys; 2019 Sep; 46(9):3893-3905. PubMed ID: 31274201 [TBL] [Abstract][Full Text] [Related]
4. Improving SNR and B1 transmit field for an endorectal coil in 7 T MRI and MRS of prostate cancer. Arteaga de Castro CS; van den Bergen B; Luijten PR; van der Heide UA; van Vulpen M; Klomp DW Magn Reson Med; 2012 Jul; 68(1):311-8. PubMed ID: 22127763 [TBL] [Abstract][Full Text] [Related]
5. In vivo prostate magnetic resonance imaging and magnetic resonance spectroscopy at 3 Tesla using a transceive pelvic phased array coil: preliminary results. Kim HW; Buckley DL; Peterson DM; Duensing GR; Caserta J; Fitzsimmons J; Blackband SJ Invest Radiol; 2003 Jul; 38(7):443-51. PubMed ID: 12821859 [TBL] [Abstract][Full Text] [Related]
6. Proton spectroscopic imaging of the human prostate at 7 T. Klomp DW; Bitz AK; Heerschap A; Scheenen TW NMR Biomed; 2009 Jun; 22(5):495-501. PubMed ID: 19170072 [TBL] [Abstract][Full Text] [Related]
7. Prostate MR imaging at 3T with a longitudinal array endorectal surface coil and phased array body coil. Kim DY; Schnall MD; Rosen MA; Connick T J Magn Reson Imaging; 2008 Jun; 27(6):1327-30. PubMed ID: 18504745 [TBL] [Abstract][Full Text] [Related]
8. MRI of prostate cancer at 1.5 and 3.0 T: comparison of image quality in tumor detection and staging. Beyersdorff D; Taymoorian K; Knösel T; Schnorr D; Felix R; Hamm B; Bruhn H AJR Am J Roentgenol; 2005 Nov; 185(5):1214-20. PubMed ID: 16247137 [TBL] [Abstract][Full Text] [Related]
9. Proton two-dimensional chemical shift imaging for evaluation of prostate cancer: external surface coil vs. endorectal surface coil. Kaji Y; Wada A; Imaoka I; Matsuo M; Terachi T; Kobashi Y; Sugimura K; Fujii M; Maruyama K; Takizawa O J Magn Reson Imaging; 2002 Dec; 16(6):697-706. PubMed ID: 12451583 [TBL] [Abstract][Full Text] [Related]
10. In vivo 31P MR spectroscopic imaging of the human prostate at 7 T: safety and feasibility. Kobus T; Bitz AK; van Uden MJ; Lagemaat MW; Rothgang E; Orzada S; Heerschap A; Scheenen TW Magn Reson Med; 2012 Dec; 68(6):1683-95. PubMed ID: 22368094 [TBL] [Abstract][Full Text] [Related]
11. Interactive deformation registration of endorectal prostate MRI using ITK thin plate splines. Cheung MR; Krishnan K Acad Radiol; 2009 Mar; 16(3):351-7. PubMed ID: 19201364 [TBL] [Abstract][Full Text] [Related]
12. Post-processing correction of the endorectal coil reception effects in MR spectroscopic imaging of the prostate. Noworolski SM; Reed GD; Kurhanewicz J; Vigneron DB J Magn Reson Imaging; 2010 Sep; 32(3):654-62. PubMed ID: 20815064 [TBL] [Abstract][Full Text] [Related]
13. Use of perfluorocarbon compound in the endorectal coil to improve MR spectroscopy of the prostate. Choi H; Ma J AJR Am J Roentgenol; 2008 Apr; 190(4):1055-9. PubMed ID: 18356455 [TBL] [Abstract][Full Text] [Related]
14. MR imaging of the prostate at 3 Tesla: comparison of an external phased-array coil to imaging with an endorectal coil at 1.5 Tesla. Sosna J; Pedrosa I; Dewolf WC; Mahallati H; Lenkinski RE; Rofsky NM Acad Radiol; 2004 Aug; 11(8):857-62. PubMed ID: 15354305 [TBL] [Abstract][Full Text] [Related]
15. [MRI of prostate cancer using three different coil systems: image quality, tumor detection, and staging]. Beyersdorff D; Darsow U; Stephan C; Schnorr D; Loening S; Taupitz M Rofo; 2003 Jun; 175(6):799-805. PubMed ID: 12811693 [TBL] [Abstract][Full Text] [Related]
16. [Magnetic resonance tomography with endorectal coil for examination of prostate and seminal vesicles]. Rørvik J Tidsskr Nor Laegeforen; 2000 Feb; 120(6):689-92. PubMed ID: 10806882 [TBL] [Abstract][Full Text] [Related]
17. Considerations in applying 3D PRESS H-1 brain MRSI with an eight-channel phased-array coil at 3 T. Li Y; Osorio JA; Ozturk-Isik E; Chen AP; Xu D; Crane JC; Cha S; Chang S; Berger MS; Vigneron DB; Nelson SJ Magn Reson Imaging; 2006 Dec; 24(10):1295-302. PubMed ID: 17145400 [TBL] [Abstract][Full Text] [Related]
18. Effect of using endorectal coil in preoperative staging of rectal carcinomas by pelvic MR imaging. Donmez FY; Tunaci M; Yekeler E; Balik E; Tunaci A; Acunas G Eur J Radiol; 2008 Jul; 67(1):139-45. PubMed ID: 17720346 [TBL] [Abstract][Full Text] [Related]
19. An inverted-microstrip resonator for human head proton MR imaging at 7 tesla. Zhang X; Ugurbil K; Sainati R; Chen W IEEE Trans Biomed Eng; 2005 Mar; 52(3):495-504. PubMed ID: 15759580 [TBL] [Abstract][Full Text] [Related]
20. Automatic conformal prescription of very selective saturation bands for in vivo 1H-MRSI of the prostate. Venugopal N; McCurdy B; Hovdebo J; Al Mehairi S; Alamri A; Sandhu GS; Sivalingam S; Drachenberg D; Ryner L NMR Biomed; 2012 Apr; 25(4):643-53. PubMed ID: 22162346 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]