BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

310 related articles for article (PubMed ID: 20979371)

  • 1. Nanoscale thermal AFM of polymers: transient heat flow effects.
    Duvigneau J; Schönherr H; Vancso GJ
    ACS Nano; 2010 Nov; 4(11):6932-40. PubMed ID: 20979371
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Glass transitions in nanoscale heated volumes of thin polystyrene films.
    Li AG; Burggraf LW
    Rev Sci Instrum; 2010 Dec; 81(12):123707. PubMed ID: 21198032
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Thermal mapping of a scanning thermal microscopy tip.
    Jóźwiak G; Wielgoszewski G; Gotszalk T; Kępiński L
    Ultramicroscopy; 2013 Oct; 133():80-7. PubMed ID: 23933596
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Noncontact sub-10 nm temperature measurement in near-field laser heating.
    Yue Y; Chen X; Wang X
    ACS Nano; 2011 Jun; 5(6):4466-75. PubMed ID: 21557563
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Topography imaging with a heated atomic force microscope cantilever in tapping mode.
    Park K; Lee J; Zhang ZM; King WP
    Rev Sci Instrum; 2007 Apr; 78(4):043709. PubMed ID: 17477672
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Scanning thermal microscopy with heat conductive nanowire probes.
    Timofeeva M; Bolshakov A; Tovee PD; Zeze DA; Dubrovskii VG; Kolosov OV
    Ultramicroscopy; 2016 Mar; 162():42-51. PubMed ID: 26735005
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ultrananocrystalline diamond tip integrated onto a heated atomic force microscope cantilever.
    Kim HJ; Moldovan N; Felts JR; Somnath S; Dai Z; Jacobs TD; Carpick RW; Carlisle JA; King WP
    Nanotechnology; 2012 Dec; 23(49):495302. PubMed ID: 23149947
    [TBL] [Abstract][Full Text] [Related]  

  • 8. High-resolution noncontact atomic force microscopy.
    Pérez R; García R; Schwarz U
    Nanotechnology; 2009 Jul; 20(26):260201. PubMed ID: 19531843
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Scanning thermal lithography of tailored tert-butyl ester protected carboxylic acid functionalized (meth)acrylate polymer platforms.
    Duvigneau J; Schönherr H; Vancso GJ
    ACS Appl Mater Interfaces; 2011 Oct; 3(10):3855-65. PubMed ID: 21919505
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ultra-high vacuum scanning thermal microscopy for nanometer resolution quantitative thermometry.
    Kim K; Jeong W; Lee W; Reddy P
    ACS Nano; 2012 May; 6(5):4248-57. PubMed ID: 22530657
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A heater-integrated scanning probe microscopy probe array with different tip radii for study of micro-nanosize effects on silicon-tip/polymer-film friction.
    Bao H; Li X
    Rev Sci Instrum; 2008 Mar; 79(3):033701. PubMed ID: 18377009
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Thermoelectric voltage at a nanometer-scale heated tip point contact.
    Fletcher PC; Lee B; King WP
    Nanotechnology; 2012 Jan; 23(3):035401. PubMed ID: 22173299
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Scanning Thermal Microscopy of Ultrathin Films: Numerical Studies Regarding Cantilever Displacement, Thermal Contact Areas, Heat Fluxes, and Heat Distribution.
    Metzke C; Kühnel F; Weber J; Benstetter G
    Nanomaterials (Basel); 2021 Feb; 11(2):. PubMed ID: 33669205
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Enabling low-noise null-point scanning thermal microscopy by the optimization of scanning thermal microscope probe through a rigorous theory of quantitative measurement.
    Hwang G; Chung J; Kwon O
    Rev Sci Instrum; 2014 Nov; 85(11):114901. PubMed ID: 25430136
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Modelling the manipulation of C60 on the Si001 surface performed with NC-AFM.
    Martsinovich N; Kantorovich L
    Nanotechnology; 2009 Apr; 20(13):135706. PubMed ID: 19420515
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Spatial differentiation of sub-micrometer domains in a poly(hydroxyalkanoate) copolymer using instrumentation that combines atomic force microscopy (AFM) and infrared (IR) spectroscopy.
    Marcott C; Lo M; Kjoller K; Prater C; Noda I
    Appl Spectrosc; 2011 Oct; 65(10):1145-50. PubMed ID: 21986074
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Nanometer-scale heat-conductivity measurements on biological samples.
    Haeberle W; Pantea M; Hoerber JK
    Ultramicroscopy; 2006; 106(8-9):678-86. PubMed ID: 16730408
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurement of polyamide and polystyrene adhesion with coated-tip atomic force microscopy.
    Thio BJ; Meredith JC
    J Colloid Interface Sci; 2007 Oct; 314(1):52-62. PubMed ID: 17583720
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Nanometer-scale flow of molten polyethylene from a heated atomic force microscope tip.
    Felts JR; Somnath S; Ewoldt RH; King WP
    Nanotechnology; 2012 Jun; 23(21):215301. PubMed ID: 22551550
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Nano/Microscale Thermal Field Distribution: Conducting Thermal Decomposition of Pyrolytic-Type Polymer by Heated AFM Probes.
    Li B; Geng Y; Yan Y
    Nanomaterials (Basel); 2020 Mar; 10(3):. PubMed ID: 32156045
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.