These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 2099749)

  • 1. Antitachycardia pacing with cardioverter-defibrillator backup for malignant ventricular dysrhythmias.
    Thomson JE; Olash J
    J Cardiovasc Nurs; 1990 Feb; 4(2):33-43. PubMed ID: 2099749
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Device therapy for ventricular tachycardia or fibrillation: the implantable cardioverter defibrillator and antitachycardia pacing.
    Arteaga WJ; Drew BJ
    Crit Care Nurs Q; 1991 Aug; 14(2):60-71. PubMed ID: 2059870
    [No Abstract]   [Full Text] [Related]  

  • 3. A practical approach to teaching the automatic implantable cardioverter-defibrillator patient.
    Veseth-Rogers J
    J Cardiovasc Nurs; 1990 Feb; 4(2):7-19. PubMed ID: 2366068
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Efficacy of automatic multimodal device therapy for ventricular tachyarrhythmias as delivered by a new implantable pacing cardioverter-defibrillator. Results of a European multicenter study of 102 implants.
    Fromer M; Brachmann J; Block M; Siebels J; Hoffmann E; Almendral J; Ohm OJ; den Dulk K; Coumel P; Camm AJ
    Circulation; 1992 Aug; 86(2):363-74. PubMed ID: 1638705
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Current role of the automatic implantable cardioverter-defibrillator in the treatment of life-threatening ventricular arrhythmias.
    Kay GN; Plumb VJ; Dailey SM; Epstein AE
    Am J Med; 1990 Jan; 88(1N):25N-34N. PubMed ID: 2195882
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The automatic implantable cardioverter defibrillator as a therapeutic modality for recurrent ventricular tachycardia: a case study.
    Kuiper RA
    Prog Cardiovasc Nurs; 1990; 5(1):6-12. PubMed ID: 2367517
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Combination of antitachycardia pacemaker and automatic implantable cardioverter/defibrillator for ventricular tachycardia.
    Manz M; Gerckens U; Funke HD; Kirchhoff PG; Lüderitz B
    Pacing Clin Electrophysiol; 1986 Sep; 9(5):676-84. PubMed ID: 2429273
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Management of malignant ventricular arrhythmias using antitachycardia devices.
    McCowan RJ; Sampath R; Lee KC; Rashid H; Cafoncelli AR; Khan ZM; Malik FS; Chapman JL; Figueroa E; Freund PE
    W V Med J; 1991 Sep; 87(9):395-9. PubMed ID: 1949755
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Automatic implantable cardioverter-defibrillator (AICD) and antitachycardia pacemaker (Tachylog 651) in the treatment of ventricular tachyarrhythmias].
    Gerckens U; Manz M; Funke HD; Kirchhoff PG; Lüderitz B
    Z Kardiol; 1987 Apr; 76(4):211-6. PubMed ID: 3604373
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Antitachycardia devices: realities and promises.
    Klein LS; Miles WM; Zipes DP
    J Am Coll Cardiol; 1991 Nov; 18(5):1349-62. PubMed ID: 1918713
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ninety-six episodes of spontaneous ventricular tachycardia in 1 week: success of ramp pacing by a pacer-cardioverter-defibrillator.
    Porterfield JG; Porterfield LM; Bray L
    Pacing Clin Electrophysiol; 1991 Oct; 14(10):1440-3. PubMed ID: 1721122
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The impact of antitachycardia pacing with defibrillation.
    Lüderitz B
    Pacing Clin Electrophysiol; 1991 Feb; 14(2 Pt 2):312-6. PubMed ID: 1706844
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Combined automatic implantable cardioverter-defibrillator and pacemaker systems: implantation techniques and follow-up.
    Epstein AE; Kay GN; Plumb VJ; Shepard RB; Kirklin JK
    J Am Coll Cardiol; 1989 Jan; 13(1):121-31. PubMed ID: 2909559
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The automated implantable cardioverter.
    DeBorde R; Aarons D; Biggs M
    AACN Clin Issues Crit Care Nurs; 1991 Feb; 2(1):170-7. PubMed ID: 1847294
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Role of antitachycardia devices in the treatment of ventricular tachyarrhythmias.
    Lüderitz B; Manz M
    Am J Cardiol; 1989 Dec; 64(20):75J-78J. PubMed ID: 2596414
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reduction in defibrillator shocks with an implantable device combining antitachycardia pacing and shock therapy.
    Leitch JW; Gillis AM; Wyse DG; Yee R; Klein GJ; Guiraudon G; Sheldon RS; Duff HJ; Kieser TM; Mitchell LB
    J Am Coll Cardiol; 1991 Jul; 18(1):145-51. PubMed ID: 2050917
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Long-term efficacy of an antitachycardia pacemaker and implantable defibrillator combination.
    Bonnet CA; Fogoros RN; Elson JJ; Fiedler SB; Burkholder JA
    Pacing Clin Electrophysiol; 1991 May; 14(5 Pt 1):814-22. PubMed ID: 1712959
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Automatic implantable cardioverter/defibrillator (AICD) and antitachycardia pacemaker (Tachylog): combined use in ventricular tachyarrhythmias.
    Lüderitz B; Gerckens U; Manz M
    Pacing Clin Electrophysiol; 1986 Nov; 9(6 Pt 2):1356-60. PubMed ID: 2432562
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Antitachycardia pacing and implantable cardioverter defibrillators.
    Furman S; Mercando AD
    Annu Rev Med; 1989; 40():123-36. PubMed ID: 2729924
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Device interaction--antitachycardia pacemakers and defibrillators for sustained ventricular tachycardia.
    Ahern TS; Nydegger C; McCormick DJ; Marinchak R; Kowey P; Horowitz LN; Worley S; Kutalek SP
    Pacing Clin Electrophysiol; 1991 Feb; 14(2 Pt 2):302-7. PubMed ID: 1706842
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.