231 related articles for article (PubMed ID: 2100174)
1. Techniques of intraocular pressure determination.
Green K
Lens Eye Toxic Res; 1990; 7(3-4):485-9. PubMed ID: 2100174
[TBL] [Abstract][Full Text] [Related]
2. Goldmann applanation versus hand-applanation and .schiötz indentation tonometry.
Krieglstein GK; Waller WK
Albrecht Von Graefes Arch Klin Exp Ophthalmol; 1975; 194(1):11-6. PubMed ID: 1079117
[TBL] [Abstract][Full Text] [Related]
3. Portable tonometers: a clinical comparison of applanation and indentation devices.
Chiara GF; Semes LP; Potter JW; Cutter GR; Tucker WR
J Am Optom Assoc; 1989 Feb; 60(2):105-10. PubMed ID: 2703651
[TBL] [Abstract][Full Text] [Related]
4. Estimation of intraocular pressure in rabbits using noncontact tonometer: a comparative evaluation with Schiotz tonometer.
Gupta SK; Saxena R; Agarwal R; Galpalli ND; Srivastava S; Agrawal SS
Methods Find Exp Clin Pharmacol; 2007; 29(6):405-9. PubMed ID: 17922069
[TBL] [Abstract][Full Text] [Related]
5. Goldmann applanation tonometry in the conscious rat.
Cohan BE; Bohr DF
Invest Ophthalmol Vis Sci; 2001 Feb; 42(2):340-2. PubMed ID: 11157864
[TBL] [Abstract][Full Text] [Related]
6. Agreement of rebound tonometer in measuring intraocular pressure with three types of applanation tonometers.
Nakamura M; Darhad U; Tatsumi Y; Fujioka M; Kusuhara A; Maeda H; Negi A
Am J Ophthalmol; 2006 Aug; 142(2):332-4. PubMed ID: 16876523
[TBL] [Abstract][Full Text] [Related]
7. [Intraocular pressure difference in Goldmann applanation tonometry versus a transpalpebral tonometer TGDc-01"PRA" in glaucoma patients].
Schlote T; Landenberger H
Klin Monbl Augenheilkd; 2005 Feb; 222(2):123-31. PubMed ID: 15719316
[TBL] [Abstract][Full Text] [Related]
8. Comparison of the use of new handheld tonometers and established applanation tonometers in dogs.
Görig C; Coenen RT; Stades FC; Djajadiningrat-Laanen SC; Boevé MH
Am J Vet Res; 2006 Jan; 67(1):134-44. PubMed ID: 16426223
[TBL] [Abstract][Full Text] [Related]
9. Comparison of the rebound tonometer (ICare) to the applanation tonometer (Tonopen XL) in normotensive dogs.
Leiva M; Naranjo C; Peña MT
Vet Ophthalmol; 2006; 9(1):17-21. PubMed ID: 16409240
[TBL] [Abstract][Full Text] [Related]
10. [Theoretical basis of goldmann applanation tonometry].
Wiegand W; Schroeder B; Hager A
Klin Monbl Augenheilkd; 2005 Jul; 222(7):552-7. PubMed ID: 16034722
[TBL] [Abstract][Full Text] [Related]
11. New ways to measure intraocular pressure.
ElMallah MK; Asrani SG
Curr Opin Ophthalmol; 2008 Mar; 19(2):122-6. PubMed ID: 18301285
[TBL] [Abstract][Full Text] [Related]
12. Comparison of three tonometers for measuring intraocular pressure in rabbits.
Abrams LS; Vitale S; Jampel HD
Invest Ophthalmol Vis Sci; 1996 Apr; 37(5):940-4. PubMed ID: 8603880
[TBL] [Abstract][Full Text] [Related]
13. [Measurement of intraocular pressure using the Tono-Pen in comparison with Goldmann applanation tonometry - a clinical study in 100 eyes].
Deuter CM; Schlote T; Hahn GA; Bende T; Derse M
Klin Monbl Augenheilkd; 2002 Mar; 219(3):138-42. PubMed ID: 11987041
[TBL] [Abstract][Full Text] [Related]
14. A comparison of Perkins and Goldmann applanation tonometry.
Baskett JS; Goen TM; Terry JE
J Am Optom Assoc; 1986 Nov; 57(11):832-4. PubMed ID: 3782712
[TBL] [Abstract][Full Text] [Related]
15. Measurement of intraocular pressure in awake mice.
Cohan BE; Bohr DF
Invest Ophthalmol Vis Sci; 2001 Oct; 42(11):2560-2. PubMed ID: 11581198
[TBL] [Abstract][Full Text] [Related]
16. Comparison of the ICare rebound tonometer with the Goldmann tonometer in a normal population.
Fernandes P; Díaz-Rey JA; Queirós A; Gonzalez-Meijome JM; Jorge J
Ophthalmic Physiol Opt; 2005 Sep; 25(5):436-40. PubMed ID: 16101950
[TBL] [Abstract][Full Text] [Related]
17. The Proview phosphene tonometer fails to measure ocular pressure accurately in clinical practice.
Alvarez TL; Gollance SA; Thomas GA; Greene RJ; Marchetto PM; Moore EJ; Realini T; Liebmann JM; Ritch R; Lama P; Fechtner RD
Ophthalmology; 2004 Jun; 111(6):1077-85. PubMed ID: 15177956
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of applanation tonometers for the dog eye.
Gelatt KN; Peiffer RL; Gum GG; Gwin RM; Erickson JL
Invest Ophthalmol Vis Sci; 1977 Oct; 16(10):963-8. PubMed ID: 908649
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of three applanation tonometers in dogs.
Priehs DR; Gum GG; Whitley RD; Moore LE
Am J Vet Res; 1990 Oct; 51(10):1547-50. PubMed ID: 2240775
[TBL] [Abstract][Full Text] [Related]
20. [Principle and results of a new "non-contact-tonometer" are discussed (author's transl)].
Draeger J; Jessen K; Haselmann G
Klin Monbl Augenheilkd; 1975 Jul; 167(1):27-34. PubMed ID: 1202268
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]