These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
96 related articles for article (PubMed ID: 2100612)
41. Amperometric glucose sensor based on coimmobilization of glucose oxidase and Poly(p-phenylenediamine) at a platinum microdisk electrode. Jing-Juan X; Hong-Yuan C Anal Biochem; 2000 May; 280(2):221-6. PubMed ID: 10790304 [TBL] [Abstract][Full Text] [Related]
42. Co-immobilized glucose oxidase and β-galactosidase on bovine serum albumin coated allyl glycidyl ether (AGE)-ethylene glycol dimethacrylate (EGDM) copolymer as a biosensor for lactose determination in milk. Jasti LS; Dola SR; Fadnavis NW; Addepally U; Daniels S; Ponrathnam S Enzyme Microb Technol; 2014 Oct; 64-65():67-73. PubMed ID: 25152419 [TBL] [Abstract][Full Text] [Related]
43. Development of amperometric biosensor for glucose based on a novel attractive enzyme immobilization matrix: calcium carbonate nanoparticles. Shan D; Zhu M; Xue H; Cosnier S Biosens Bioelectron; 2007 Mar; 22(8):1612-7. PubMed ID: 16920350 [TBL] [Abstract][Full Text] [Related]
44. Covalently bound phosphate residues in bovine milk xanthine oxidase and in glucose oxidase from Aspergillus niger: a reevaluation. Johnson JL; London RE; Rajagopalan KV Proc Natl Acad Sci U S A; 1989 Sep; 86(17):6493-7. PubMed ID: 2505251 [TBL] [Abstract][Full Text] [Related]
45. An integrated bienzyme glucose oxidase-fructose dehydrogenase-tetrathiafulvalene-3-mercaptopropionic acid-gold electrode for the simultaneous determination of glucose and fructose. Campuzano S; Loaiza OA; Pedrero M; de Villena FJ; Pingarrón JM Bioelectrochemistry; 2004 Jun; 63(1-2):199-206. PubMed ID: 15110273 [TBL] [Abstract][Full Text] [Related]
47. Amperometric glucose biosensor based on assisted ion transfer through gel-supported microinterfaces. Pereira CM; Oliveira JM; Silva RM; Silva F Anal Chem; 2004 Sep; 76(18):5547-51. PubMed ID: 15362919 [TBL] [Abstract][Full Text] [Related]
48. A glucose biosensor based on an oxygen electrode: in-vitro performances in model buffer solution and in blood plasma. Yang S; Atanasov P; Wilkins E Biomed Instrum Technol; 1996; 30(1):55-61. PubMed ID: 8850596 [TBL] [Abstract][Full Text] [Related]
49. Determination of total creatine kinase activity in blood serum using an amperometric biosensor based on glucose oxidase and hexokinase. Kucherenko IS; Soldatkin OO; Lagarde F; Jaffrezic-Renault N; Dzyadevych SV; Soldatkin AP Talanta; 2015 Nov; 144():604-11. PubMed ID: 26452867 [TBL] [Abstract][Full Text] [Related]
50. Direct electrochemistry of glucose oxidase and biosensing for glucose based on boron-doped carbon-coated nickel modified electrode. Yang L; Xiong H; Zhang X; Wang S; Zhang X Biosens Bioelectron; 2011 May; 26(9):3801-5. PubMed ID: 21419620 [TBL] [Abstract][Full Text] [Related]
51. Amperometric enzyme electrodes for aerobic and anaerobic glucose monitoring prepared by glucose oxidase immobilized in mixed ferrocene-cobaltocenium dendrimers. Alonso B; Armada PG; Losada J; Cuadrado I; González B; Casado CM Biosens Bioelectron; 2004 Jul; 19(12):1617-25. PubMed ID: 15142595 [TBL] [Abstract][Full Text] [Related]
52. An amperometric biosensor for uric acid determination prepared from uricase immobilized in polypyrrole film. Cete S; Yaşar A; Arslan F Artif Cells Blood Substit Immobil Biotechnol; 2006; 34(3):367-80. PubMed ID: 16809136 [TBL] [Abstract][Full Text] [Related]
53. Enhancing biosensor properties of conducting polymers via copolymerization: Synthesis of EDOT-substituted bis(2-pyridylimino)isoindolato-palladium complex and electrochemical sensing of glucose by its copolymerized film. Tekbaşoğlu TY; Soganci T; Ak M; Koca A; Şener MK Biosens Bioelectron; 2017 Jan; 87():81-88. PubMed ID: 27522481 [TBL] [Abstract][Full Text] [Related]
54. Lactose biosensor based on Langmuir-Blodgett films of poly(3-hexyl thiophene). Sharma SK; Singhal R; Malhotra BD; Sehgal N; Kumar A Biosens Bioelectron; 2004 Oct; 20(3):651-7. PubMed ID: 15494251 [TBL] [Abstract][Full Text] [Related]
55. Amperometric glucose biosensor based on polymerized ionic liquid microparticles. López MS; Mecerreyes D; López-Cabarcos E; López-Ruiz B Biosens Bioelectron; 2006 Jun; 21(12):2320-8. PubMed ID: 16616485 [TBL] [Abstract][Full Text] [Related]
56. Amperometric glucose biosensor based on adsorption of glucose oxidase at platinum nanoparticle-modified carbon nanotube electrode. Tang H; Chen J; Yao S; Nie L; Deng G; Kuang Y Anal Biochem; 2004 Aug; 331(1):89-97. PubMed ID: 15246000 [TBL] [Abstract][Full Text] [Related]
57. Photostructurized electrochemical biosensors for bioreactor control and measurement in body fluids. Lobmaier C; Schalkhammer T; Hawa G; Ecker B; Pittner F J Mol Recognit; 1995; 8(1-2):146-50. PubMed ID: 7598948 [TBL] [Abstract][Full Text] [Related]
58. Signal amplification in enzyme-based amperometric biosensors. Karra S; Gorski W Anal Chem; 2013 Nov; 85(21):10573-80. PubMed ID: 24099638 [TBL] [Abstract][Full Text] [Related]
59. Electronically type-sorted carbon nanotube-based electrochemical biosensors with glucose oxidase and dehydrogenase. Muguruma H; Hoshino T; Nowaki K ACS Appl Mater Interfaces; 2015 Jan; 7(1):584-92. PubMed ID: 25522366 [TBL] [Abstract][Full Text] [Related]
60. A mediated polyphenol oxidase biosensor immobilized by electropolymerization of 1,2-diamino benzene. Akyilmaz E; Kozgus O; Türkmen H; Cetinkaya B Bioelectrochemistry; 2010 Jun; 78(2):135-40. PubMed ID: 19783226 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]