BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

321 related articles for article (PubMed ID: 21033954)

  • 1. Electron cyclotron emission diagnostics on KSTAR tokamak.
    Jeong SH; Lee KD; Kogi Y; Kawahata K; Nagayama Y; Mase A; Kwon M
    Rev Sci Instrum; 2010 Oct; 81(10):10D922. PubMed ID: 21033954
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of multichannel intermediate frequency system for electron cyclotron emission radiometer on KSTAR Tokamak.
    Kogi Y; Sakoda T; Mase A; Ito N; Yokota Y; Yamaguchi S; Nagayama Y; Jeong SH; Kwon M; Kawahata K
    Rev Sci Instrum; 2008 Oct; 79(10):10F115. PubMed ID: 19044599
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Diagnostics for first plasma and development plan on KSTAR.
    Lee JH; Na HK; Lee SG; Bak JG; Seo DC; Seo SH; Oh ST; Ko WH; Chung J; Nam YU; Lee KD; Ka EM; Oh YK; Kwon M; Jeong SH
    Rev Sci Instrum; 2010 Jun; 81(6):063502. PubMed ID: 20590236
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Calibration of electron cyclotron emission radiometer for KSTAR.
    Kogi Y; Jeong SH; Lee KD; Akaki K; Mase A; Kuwahara D; Yoshinaga T; Nagayama Y; Kwon M; Kawahata K
    Rev Sci Instrum; 2010 Oct; 81(10):10D916. PubMed ID: 21033948
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A 16-channel heterodyne electron cyclotron emission radiometer on J-TEXT.
    Yang ZJ; Phillips PE; Zhuang G; Xiao JS; Huang H; Rowan WL; Wang ZJ
    Rev Sci Instrum; 2012 Oct; 83(10):10E313. PubMed ID: 23126973
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Design and characterization of a 32-channel heterodyne radiometer for electron cyclotron emission measurements on experimental advanced superconducting tokamak.
    Han X; Liu X; Liu Y; Domier CW; Luhmann NC; Li EZ; Hu LQ; Gao X
    Rev Sci Instrum; 2014 Jul; 85(7):073506. PubMed ID: 25085139
    [TBL] [Abstract][Full Text] [Related]  

  • 7. First neutral beam injection experiments on KSTAR tokamak.
    Jeong SH; Chang DH; Kim TS; In SR; Lee KW; Jin JT; Chang DS; Oh BH; Bae YS; Kim JS; Park HT; Watanabe K; Inoue T; Kashiwagi M; Dairaku M; Tobari H; Hanada M
    Rev Sci Instrum; 2012 Feb; 83(2):02B102. PubMed ID: 22380259
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Innovations in optical coupling of the KSTAR electron cyclotron emission imaging diagnostic.
    Liang T; Tobias B; Kong X; Domier CW; Luhmann NC; Lee W; Yun GS; Park HK
    Rev Sci Instrum; 2010 Oct; 81(10):10D909. PubMed ID: 21033941
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Electron cyclotron-electron Bernstein wave emission diagnostics for the COMPASS tokamak.
    Zajac J; Preinhaelter J; Urban J; Zacek F; Sestak D; Nanobashvili S
    Rev Sci Instrum; 2010 Oct; 81(10):10D911. PubMed ID: 21033943
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Relatively scaled ECE temperature profiles of KSTAR plasmas.
    Choi MJ; Yun GS; Park HK; Jeon YM; Jeong SH
    Rev Sci Instrum; 2010 Oct; 81(10):10D934. PubMed ID: 21033962
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Design of a Doppler reflectometer for KSTAR.
    Lee KD; Nam YU; Seo SH; Kim YS
    Rev Sci Instrum; 2014 Nov; 85(11):11D858. PubMed ID: 25430271
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Intermediate frequency band digitized high dynamic range radiometer system for plasma diagnostics and real-time Tokamak control.
    Bongers WA; van Beveren V; Thoen DJ; Nuij PJ; de Baar MR; Donné AJ; Westerhof E; Goede AP; Krijger B; van den Berg MA; Kantor M; Graswinckel MF; Hennen BA; Schüller FC
    Rev Sci Instrum; 2011 Jun; 82(6):063508. PubMed ID: 21721692
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A 280 GHz single-channel millimeter-wave interferometer system for KSTAR.
    Nam YU; Lee KD
    Rev Sci Instrum; 2008 Oct; 79(10):10E705. PubMed ID: 19044523
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development of KSTAR Thomson scattering system.
    Lee JH; Oh ST; Wi HM
    Rev Sci Instrum; 2010 Oct; 81(10):10D528. PubMed ID: 21033883
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Upgrade of the ECE diagnostic on EAST.
    Zhao H; Zhou T; Liu Y; Ti A; Ling B; Austin ME; Houshmandyar S; Huang H; Rowan WL; Hu L
    Rev Sci Instrum; 2018 Oct; 89(10):10H111. PubMed ID: 30399748
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Radiometry for the vertical electron cyclotron emission from the runaway electrons at the COMPASS tokamak.
    Farník M; Urban J; Zajac J; Bogár O; Varavin M; Casolari A; Čeřovský J; Ficker O; Mlynář J; Macúšová E; Weinzettl V; Hron M
    Rev Sci Instrum; 2019 Nov; 90(11):113501. PubMed ID: 31779455
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Data acquisition and processing system of the electron cyclotron emission imaging system of the KSTAR tokamak.
    Kim JB; Lee W; Yun GS; Park HK; Domier CW; Luhmann NC
    Rev Sci Instrum; 2010 Oct; 81(10):10D931. PubMed ID: 21033959
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparative electron temperature measurements of Thomson scattering and electron cyclotron emission diagnostics in TCABR plasmas.
    Alonso MP; Figueiredo AC; Borges FO; Elizondo JI; Galvão RM; Severo JH; Usuriaga OC; Berni LA; Machida M
    Rev Sci Instrum; 2010 Oct; 81(10):10D529. PubMed ID: 21033884
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Analysis of line integrated electron density using plasma position data on Korea Superconducting Tokamak Advanced Research.
    Nam YU; Chung J
    Rev Sci Instrum; 2010 Oct; 81(10):10D510. PubMed ID: 21033865
    [TBL] [Abstract][Full Text] [Related]  

  • 20. First results of the resistive bolometers on KSTAR.
    Seo D; Peterson BJ; Lee SH
    Rev Sci Instrum; 2010 Oct; 81(10):10E128. PubMed ID: 21033992
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.