BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 21033971)

  • 1. Simulated plasma facing component measurements for an in situ surface diagnostic on Alcator C-Mod.
    Hartwig ZS; Whyte DG
    Rev Sci Instrum; 2010 Oct; 81(10):10E106. PubMed ID: 21033971
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An in situ accelerator-based diagnostic for plasma-material interactions science on magnetic fusion devices.
    Hartwig ZS; Barnard HS; Lanza RC; Sorbom BN; Stahle PW; Whyte DG
    Rev Sci Instrum; 2013 Dec; 84(12):123503. PubMed ID: 24387430
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Novel energy resolving x-ray pinhole camera on Alcator C-Mod.
    Pablant NA; Delgado-Aparicio L; Bitter M; Brandstetter S; Eikenberry E; Ellis R; Hill KW; Hofer P; Schneebeli M
    Rev Sci Instrum; 2012 Oct; 83(10):10E526. PubMed ID: 23127033
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A spatially resolving x-ray crystal spectrometer for measurement of ion-temperature and rotation-velocity profiles on the Alcator C-Mod tokamak.
    Hill KW; Bitter ML; Scott SD; Ince-Cushman A; Reinke M; Rice JE; Beiersdorfer P; Gu MF; Lee SG; Broennimann Ch; Eikenberry EF
    Rev Sci Instrum; 2008 Oct; 79(10):10E320. PubMed ID: 19044482
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Preliminary results from the Alcator C-Mod polarimeter.
    Xu P; Irby JH; Bergerson WF; Bosco J; Brower DL; Ding WX; Kanojia A; Leccacorvi R; Mansfield DK; Marmar ES; Michael P; Murray R; Rokhman Y; Vieira R
    Rev Sci Instrum; 2010 Oct; 81(10):10D507. PubMed ID: 21033862
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Energetic ion loss detector on the Alcator C-Mod tokamak.
    Pace DC; Granetz RS; Vieira R; Bader A; Bosco J; Darrow DS; Fiore C; Irby J; Parker RR; Parkin W; Reinke ML; Terry JL; Wolfe SM; Wukitch SJ; Zweben SJ
    Rev Sci Instrum; 2012 Jul; 83(7):073501. PubMed ID: 22852689
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Wide-view charge exchange recombination spectroscopy diagnostic for Alcator C-Mod.
    Rowan WL; Bespamyatnov IO; Granetz RS
    Rev Sci Instrum; 2008 Oct; 79(10):10F529. PubMed ID: 19044672
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Direct detection of lower hybrid wave using a reflectometer on Alcator C-Mod.
    Shiraiwa S; Baek S; Dominguez A; Marmar E; Parker R; Kramer GJ
    Rev Sci Instrum; 2010 Oct; 81(10):10D936. PubMed ID: 21033964
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Surface thermocouples for measurement of pulsed heat flux in the divertor of the Alcator C-Mod tokamak.
    Brunner D; LaBombard B
    Rev Sci Instrum; 2012 Mar; 83(3):033501. PubMed ID: 22462916
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Wall scanning probe for high-field side plasma measurements on Alcator C-Mod.
    Smick N; LaBombard B
    Rev Sci Instrum; 2009 Feb; 80(2):023502. PubMed ID: 19256643
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Scanning retarding field analyzer for plasma profile measurements in the boundary of the Alcator C-Mod tokamak.
    Brunner D; LaBombard B; Ochoukov R; Whyte D
    Rev Sci Instrum; 2013 Mar; 84(3):033502. PubMed ID: 23556816
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Experimental and theoretical study of quasicoherent fluctuations in enhanced D(alpha) plasmas in the Alcator C-Mod tokamak.
    Mazurenko A; Porkolab M; Mossessian D; Snipes JA; Xu XQ; Nevins WM
    Phys Rev Lett; 2002 Nov; 89(22):225004. PubMed ID: 12485077
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Wall reflection issues for optical diagnostics in fusion devices.
    Lotte P; Aumeunier MH; Devynck P; Fenzi C; Martin V; Travère JM
    Rev Sci Instrum; 2010 Oct; 81(10):10E120. PubMed ID: 21033985
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Feedback system for divertor impurity seeding based on real-time measurements of surface heat flux in the Alcator C-Mod tokamak.
    Brunner D; Burke W; Kuang AQ; LaBombard B; Lipschultz B; Wolfe S
    Rev Sci Instrum; 2016 Feb; 87(2):023504. PubMed ID: 26931846
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The Thomson scattering system on the lithium tokamak experiment.
    Strickler T; Majeski R; Kaita R; LeBlanc B
    Rev Sci Instrum; 2008 Oct; 79(10):10E738. PubMed ID: 19044554
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Divertor IR thermography on Alcator C-Mod.
    Terry JL; LaBombard B; Brunner D; Payne J; Wurden GA
    Rev Sci Instrum; 2010 Oct; 81(10):10E513. PubMed ID: 21034041
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Multichannel Doppler transmission grating spectrometer at the Alcator C-Mod tokamak.
    Graf A; May M; Beiersdorfer P
    Rev Sci Instrum; 2008 Oct; 79(10):10F544. PubMed ID: 19044686
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A dynamic monitoring approach for the surface morphology evolution measurement of plasma facing components by means of speckle interferometry.
    Wang H; Cui X; Feng C; Li Y; Zhao M; Luo G; Ding H
    Rev Sci Instrum; 2017 Nov; 88(11):113508. PubMed ID: 29195382
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Vacuum ultraviolet impurity spectroscopy on the Alcator C-Mod tokamak.
    Reinke ML; Beiersdorfer P; Howard NT; Magee EW; Podpaly Y; Rice JE; Terry JL
    Rev Sci Instrum; 2010 Oct; 81(10):10D736. PubMed ID: 21033927
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Design of a new optical system for Alcator C-Mod motional Stark effect diagnostic.
    Ko J; Scott S; Bitter M; Lerner S
    Rev Sci Instrum; 2008 Oct; 79(10):10F520. PubMed ID: 19044665
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.