These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
168 related articles for article (PubMed ID: 21033994)
1. Biasing, acquisition, and interpretation of a dense Langmuir probe array in NSTX. Jaworski MA; Kallman J; Kaita R; Kugel H; LeBlanc B; Marsala R; Ruzic DN Rev Sci Instrum; 2010 Oct; 81(10):10E130. PubMed ID: 21033994 [TBL] [Abstract][Full Text] [Related]
2. High density Langmuir probe array for NSTX scrape-off layer measurements under lithiated divertor conditions. Kallman J; Jaworski MA; Kaita R; Kugel H; Gray TK Rev Sci Instrum; 2010 Oct; 81(10):10E117. PubMed ID: 21033982 [TBL] [Abstract][Full Text] [Related]
3. Diagnostics for the biased electrode experiment on NSTX. Roquemore AL; Zweben SJ; Kaita R; Marsalsa RJ; Bush CE; Maqueda RJ Rev Sci Instrum; 2008 Oct; 79(10):10F124. PubMed ID: 19044608 [TBL] [Abstract][Full Text] [Related]
4. Triple probe signal detection electronics for systems lacking a well defined ground. Compeau R; Gilmore M; Watts C Rev Sci Instrum; 2008 Oct; 79(10):10F128. PubMed ID: 19044612 [TBL] [Abstract][Full Text] [Related]
5. Langmuir probe diagnostic suite in the C-2 field-reversed configuration. Roche T; Sun X; Armstrong S; Knapp K; Slepchenkov M Rev Sci Instrum; 2014 Nov; 85(11):11D824. PubMed ID: 25430237 [TBL] [Abstract][Full Text] [Related]
6. Spatiotemporal temperature fluctuation measurements by means of a fast swept Langmuir probe array. Schubert M; Endler M; Thomsen H Rev Sci Instrum; 2007 May; 78(5):053505. PubMed ID: 17552818 [TBL] [Abstract][Full Text] [Related]
12. Diagnostic options for radiative divertor feedback control on NSTX-U. Soukhanovskii VA; Gerhardt SP; Kaita R; McLean AG; Raman R Rev Sci Instrum; 2012 Oct; 83(10):10D716. PubMed ID: 23126890 [TBL] [Abstract][Full Text] [Related]
13. Measurement of natural plasma flow along the field lines in the scrape-Off layer on the JT-60U divertor tokamak. Asakura N; Sakurai S; Shimada M; Koide Y; Hosogane N; Itami K Phys Rev Lett; 2000 Apr; 84(14):3093-6. PubMed ID: 11019020 [TBL] [Abstract][Full Text] [Related]
14. The flush-mounted rail Langmuir probe array designed for the Alcator C-Mod vertical target plate divertor. Kuang AQ; Brunner D; LaBombard B; Leccacorvi R; Vieira R Rev Sci Instrum; 2018 Apr; 89(4):043512. PubMed ID: 29716369 [TBL] [Abstract][Full Text] [Related]
17. Mirror Langmuir probe: a technique for real-time measurement of magnetized plasma conditions using a single Langmuir electrode. LaBombard B; Lyons L Rev Sci Instrum; 2007 Jul; 78(7):073501. PubMed ID: 17672759 [TBL] [Abstract][Full Text] [Related]
18. Fringe-jump corrected far infrared tangential interferometer/polarimeter for a real-time density feedback control system of NSTX plasmas. Juhn JW; Lee KC; Hwang YS; Domier CW; Luhmann NC; Leblanc BP; Mueller D; Gates DA; Kaita R Rev Sci Instrum; 2010 Oct; 81(10):10D540. PubMed ID: 21033892 [TBL] [Abstract][Full Text] [Related]
19. Multichannel Langmuir probe for turbulence study in Heliotron J. Ohshima S; Yamamoto S; Takeuchi M; Nagasaki K; Mizuuchi T; Okada H; Minami T; Kobayashi S; Hanatani K; Konoshima S; Sano F Rev Sci Instrum; 2010 Oct; 81(10):10E137. PubMed ID: 21033998 [TBL] [Abstract][Full Text] [Related]