These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

230 related articles for article (PubMed ID: 21034000)

  • 1. Hard x-ray transmission crystal spectrometer at the OMEGA-EP laser facility.
    Seely JF; Szabo CI; Feldman U; Hudson LT; Henins A; Audebert P; Brambrink E
    Rev Sci Instrum; 2010 Oct; 81(10):10E301. PubMed ID: 21034000
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Scaling studies with the dual crystal spectrometer at the OMEGA-EP laser facility.
    Szabo CI; Workman J; Flippo K; Feldman U; Seely JF; Hudson LT; Henins A
    Rev Sci Instrum; 2010 Oct; 81(10):10E320. PubMed ID: 21034018
    [TBL] [Abstract][Full Text] [Related]  

  • 3. X-ray crystal spectrometer for opacity measurements in the 8-18 Å spectral range at the LULI laser facility.
    Reverdin C; Thais F; Loisel G; Bougeard M
    Rev Sci Instrum; 2010 Oct; 81(10):10E327. PubMed ID: 21034025
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurement of high-energy (10-60 keV) x-ray spectral line widths with eV accuracy.
    Seely JF; Glover JL; Hudson LT; Ralchenko Y; Henins A; Pereira N; Feldman U; Di Stefano CA; Kuranz CC; Drake RP; Chen H; Williams GJ; Park J
    Rev Sci Instrum; 2014 Nov; 85(11):11D618. PubMed ID: 25430194
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Spatial resolution of a hard x-ray CCD detector.
    Seely JF; Pereira NR; Weber BV; Schumer JW; Apruzese JP; Hudson LT; Szabo CI; Boyer CN; Skirlo S
    Appl Opt; 2010 Aug; 49(23):4372-8. PubMed ID: 20697439
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Enhanced x-ray resolving power achieved behind the focal circles of Cauchois spectrometers.
    Seely JF; Hudson LT; Holland GE; Henins A
    Appl Opt; 2008 May; 47(15):2767-78. PubMed ID: 18493282
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hard x-ray spectrometer calibrations using a portable 120 kV x-ray source.
    Seely JF
    Rev Sci Instrum; 2022 Sep; 93(9):093529. PubMed ID: 36182475
    [TBL] [Abstract][Full Text] [Related]  

  • 8. X-ray diagnostic calibration with the tabletop laser facility EQUINOX.
    Reverdin C; Paurisse M; Caillaud T; Combis P; Duval A; Gontier D; Husson D; Rubbelynck C; Zuber C
    Rev Sci Instrum; 2008 Oct; 79(10):10E932. PubMed ID: 19044587
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Efficiency calibrations of cylindrically bent transmission crystals in the 20 to 80 keV x-ray energy range.
    Szabo CI; Feldman U; Seltzer S; Hudson LT; O'Brien M; Park HS; Seely JF
    Opt Lett; 2011 Apr; 36(8):1335-7. PubMed ID: 21499348
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A dual-channel, curved-crystal spectrograph for petawatt laser, x-ray backlighter source studies.
    Theobald W; Stoeckl C; Jaanimagi PA; Nilson PM; Storm M; Meyerhofer DD; Sangster TC; Hey D; MacKinnon AJ; Park HS; Patel PK; Shepherd R; Snavely RA; Key MH; King JA; Zhang B; Stephens RB; Akli KU; Highbarger K; Daskalova RL; Van Woerkom L; Freeman RR; Green JS; Gregori G; Lancaster K; Norreys PA
    Rev Sci Instrum; 2009 Aug; 80(8):083501. PubMed ID: 19725649
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Bragg diffraction using a 100 ps 17.5 keV x-ray backlighter and the Bragg diffraction imager.
    Maddox BR; Park HS; Hawreliak J; Elsholz A; Van Maren R; Remington BA; Comley A; Wark JS
    Rev Sci Instrum; 2010 Oct; 81(10):10E522. PubMed ID: 21034050
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Diagnostic development in precise opacity measurement of radiatively heated Al plasma on Shenguang II laser facility.
    Zhao Y; Yang J; Zhang J; Liu J; Yuan X; Jin F
    Rev Sci Instrum; 2009 Apr; 80(4):043505. PubMed ID: 19405658
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High resolution absorption spectroscopy of exploding wire plasmas using an x-pinch x-ray source and spherically bent crystal.
    Knapp PF; Pikuz SA; Shelkovenko TA; Hammer DA; Hansen SB
    Rev Sci Instrum; 2011 Jun; 82(6):063501. PubMed ID: 21721685
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dynamic Hohlraums as x-ray sources in high-energy density science.
    Hansen JF; Glendinning SG; Heeter RF; Brockington SJ
    Rev Sci Instrum; 2008 Jan; 79(1):013504. PubMed ID: 18248031
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Microfocusing of hard X-rays with cylindrically bent crystal monochromators.
    Schulze C; Lienert U; Hanfland M; Lorenzen M; Zontone F
    J Synchrotron Radiat; 1998 Mar; 5(Pt 2):77-81. PubMed ID: 16687807
    [TBL] [Abstract][Full Text] [Related]  

  • 16. X-ray grating spectrometer for opacity measurements in the 50 eV to 250 eV spectral range at the LULI 2000 laser facility.
    Reverdin C; Thais F; Loisel G; Busquet M; Bastiani-Ceccotti S; Blenski T; Caillaud T; Ducret JE; Foelsner W; Gilles D; Gilleron F; Pain JC; Poirier M; Serres F; Silvert V; Soullie G; Turck-Chieze S; Villette B
    Rev Sci Instrum; 2012 Oct; 83(10):10E134. PubMed ID: 23126955
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transmission crystal x-ray spectrometer covering the 6 keV-18 keV energy range with E∕ΔE = 1800 instrumental resolving power.
    Seely J; Feldman U; Brown C; Pereira N; Hudson L; Glover J; Silver E
    Rev Sci Instrum; 2012 Oct; 83(10):10E112. PubMed ID: 23126934
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An evaluation of high energy bremsstrahlung background in point-projection x-ray radiography experiments.
    Krauland CM; Jarrott LC; Drake RP; Keiter PA; Kuranz CC; Westover B; Sawada H; Kaczala DN; Bonofiglo P
    Rev Sci Instrum; 2012 Oct; 83(10):10E528. PubMed ID: 23127035
    [TBL] [Abstract][Full Text] [Related]  

  • 19. High-resolution spectroscopy on an X-ray absorption beamline.
    Hazemann JL; Proux O; Nassif V; Palancher H; Lahera E; Da Silva C; Braillard A; Testemale D; Diot MA; Alliot I; Del Net W; Manceau A; Gélébart F; Morand M; Dermigny Q; Shukla A
    J Synchrotron Radiat; 2009 Mar; 16(Pt 2):283-92. PubMed ID: 19240341
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Application of a transmission crystal x-ray spectrometer to moderate-intensity laser driven sources.
    Mao JY; Chen LM; Hudson LT; Seely JF; Zhang L; Sun YQ; Lin XX; Zhang J
    Rev Sci Instrum; 2012 Apr; 83(4):043104. PubMed ID: 22559512
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.