These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 21036280)

  • 1. Performance and reliability of a variable rate, force/displacement application system.
    Vaillant M; Pickar JG; Kawchuk GN
    J Manipulative Physiol Ther; 2010 Oct; 33(8):585-93. PubMed ID: 21036280
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The reliability of a posterior-to-anterior spinal stiffness measuring system in a population of patients with low back pain.
    Owens EF; DeVocht JW; Wilder DG; Gudavalli MR; Meeker WC
    J Manipulative Physiol Ther; 2007 Feb; 30(2):116-23. PubMed ID: 17320732
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Within- and between-day reliability of spinal stiffness measurements obtained using a computer controlled mechanical indenter in individuals with and without low back pain.
    Wong AY; Kawchuk G; Parent E; Prasad N
    Man Ther; 2013 Oct; 18(5):395-402. PubMed ID: 23465962
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect of duration and amplitude of spinal manipulative therapy (SMT) on spinal stiffness.
    Vaillant M; Edgecombe T; Long CR; Pickar JG; Kawchuk GN
    Man Ther; 2012 Dec; 17(6):577-83. PubMed ID: 22809745
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effect of application site of spinal manipulative therapy (SMT) on spinal stiffness.
    Edgecombe TL; Kawchuk GN; Long CR; Pickar JG
    Spine J; 2015 Jun; 15(6):1332-8. PubMed ID: 24139864
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measurement and analysis of the in vivo posteroanterior impulse response of the human thoracolumbar spine: a feasibility study.
    Nathan M; Keller TS
    J Manipulative Physiol Ther; 1994 Sep; 17(7):431-41. PubMed ID: 7989876
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of spinal manipulative therapy biomechanical parameters on clinical and biomechanical outcomes of participants with chronic thoracic pain: a randomized controlled experimental trial.
    Pagé I; Descarreaux M
    BMC Musculoskelet Disord; 2019 Jan; 20(1):29. PubMed ID: 30658622
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measuring the posteroanterior stiffness of the cervical spine.
    Snodgrass SJ; Rivett DA; Robertson VJ
    Man Ther; 2008 Dec; 13(6):520-8. PubMed ID: 17910931
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The role of preload forces in spinal manipulation: experimental investigation of kinematic and electromyographic responses in healthy adults.
    Nougarou F; Dugas C; Loranger M; Pagé I; Descarreaux M
    J Manipulative Physiol Ther; 2014 Jun; 37(5):287-93. PubMed ID: 24928637
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mechanical force spinal manipulation increases trunk muscle strength assessed by electromyography: a comparative clinical trial.
    Keller TS; Colloca CJ
    J Manipulative Physiol Ther; 2000; 23(9):585-95. PubMed ID: 11145798
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reliability of assisted indentation in measuring lumbar spinal stiffness.
    Stanton TR; Kawchuk GN
    Man Ther; 2009 Apr; 14(2):197-205. PubMed ID: 18375172
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of a new device for measuring responses to posteroanterior forces in a patient population, Part 1: Reliability testing.
    Latimer J; Goodsel MM; Lee M; Maher CG; Wilkinson BN; Moran CC
    Phys Ther; 1996 Feb; 76(2):158-65. PubMed ID: 8592719
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effects of high and low loading forces on measured values of lumbar stiffness.
    Latimer J; Lee M; Adams RD
    J Manipulative Physiol Ther; 1998; 21(3):157-63. PubMed ID: 9567234
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The bench-top accuracy of the VerteTrack spinal stiffness assessment device.
    Young A; Swain MS; Kawchuk GN; Wong AYL; Downie AS
    Chiropr Man Therap; 2020 Aug; 28(1):42. PubMed ID: 32807186
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reliability of a new loaded rolling wheel system for measuring spinal stiffness in asymptomatic participants.
    Hadizadeh M; Kawchuk GN; Parent E
    BMC Musculoskelet Disord; 2019 Apr; 20(1):176. PubMed ID: 31018853
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Rate of force application during knee arthrometer testing affects stiffness but not displacement measurements.
    Gross SM; Carcia CR; Gansneder BM; Shultz SJ
    J Orthop Sports Phys Ther; 2004 Mar; 34(3):132-9. PubMed ID: 15089026
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A novel method of measuring passive quasi-stiffness in the first metatarsophalangeal joint.
    Heng ML; Chua YK; Pek HK; Krishnasamy P; Kong PW
    J Foot Ankle Res; 2016; 9():41. PubMed ID: 27800027
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Posterior-anterior(PA) pressure Puffin for measuring and treating spinal stiffness: Mechanism and repeatability.
    Björnsdóttir SV; Guðmundsson G; Auðunsson GA; Matthíasson J; Ragnarsdóttir M
    Man Ther; 2016 Apr; 22():72-9. PubMed ID: 26559318
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Is the clinical concept of spinal stiffness multidimensional?
    Maher C; Adams R
    Phys Ther; 1995 Oct; 75(10):854-60; discussion 861-4. PubMed ID: 7568385
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Learning Spinal Manipulation: Objective and Subjective Assessment of Performance.
    Pasquier M; Chéron C; Barbier G; Dugas C; Lardon A; Descarreaux M
    J Manipulative Physiol Ther; 2020; 43(3):189-196. PubMed ID: 32951767
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.