These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

86 related articles for article (PubMed ID: 21038456)

  • 1. Some new selective stationary phases for RP-HPLC.
    Jardim IC; Maldaner L; Lourenço J; Fioravanti LM; Collins CH
    J Sep Sci; 2010 Oct; 33(19):2917-29. PubMed ID: 21038456
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Stability studies of stationary phases from poly(methyltetradecylsiloxane) sorbed and immobilized onto metalized and unmodified silicas.
    Faria AM; Tonhi E; Collins KE; Collins CH
    J Sep Sci; 2007 Aug; 30(12):1844-51. PubMed ID: 17638361
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Characterization of stationary phases based on polysiloxanes thermally immobilized onto silica and metalized silica using supercritical fluid chromatography with the solvation parameter model.
    da Silva CG; Collins CH; Lesellier E; West C
    J Chromatogr A; 2013 Nov; 1315():176-87. PubMed ID: 24079548
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Preparation and characterization of poly(methyltetradecylsiloxane) stationary phases immobilized by gamma radiation onto zirconized silica.
    Faria AM; Collins KE; Collins CH
    J Chromatogr A; 2007 Jul; 1156(1-2):51-9. PubMed ID: 17084847
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Selectivity of some basic solutes on a poly(methyltetradecylsiloxane)-silica stationary phase.
    Borges EM; Collins CH
    J Sep Sci; 2011 Nov; 34(21):3011-9. PubMed ID: 21936053
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Improved chemical stabilities for end-capped high performance liquid chromatography stationary phases based on poly(methyloctadecylsiloxane) thermally immobilized onto metalized silicas.
    da Silva CG; Collins CH
    J Chromatogr A; 2012 Oct; 1260():81-7. PubMed ID: 22964048
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Characterization of several stationary phases prepared by thermal immobilization of poly(methyltetradecylsiloxane) onto silica surfaces.
    Borges EM; Collins CH
    J Chromatogr A; 2011 Jul; 1218(28):4378-88. PubMed ID: 21636090
    [TBL] [Abstract][Full Text] [Related]  

  • 8. New stationary phases for high-performance liquid chromatography based on poly(methyltetradecylsiloxane) thermally immobilized onto zirconized silica.
    Faria AM; Collins KE; Collins CH
    J Chromatogr A; 2006 Jul; 1122(1-2):114-22. PubMed ID: 16696991
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High-performance liquid chromatographic stationary phases based on polysiloxanes with different chain lengths thermally immobilized on silica supports.
    Tonhi E; Collins KE; Collins CH
    J Chromatogr A; 2006 Jun; 1119(1-2):135-9. PubMed ID: 16430910
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Immobilized polymeric stationary phases using metalized silica supports.
    Faria AM; Jardim IC; Collins KE; Collins CH
    J Sep Sci; 2006 Apr; 29(6):782-9. PubMed ID: 16830490
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of a polymer-coated stationary phase with improved chemical stability in alkaline mobile phases.
    Faria AM; Silva CR; Collins CH; Jardim IC
    J Sep Sci; 2008 Apr; 31(6-7):953-60. PubMed ID: 18327851
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of pH and temperature on the chromatographic performance and stability of immobilized poly(methyloctylsiloxane) stationary phases.
    Borges EM; Collins CH
    J Chromatogr A; 2012 Mar; 1227():174-80. PubMed ID: 22277182
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Description and comparison of chromatographic tests and chemometric methods for packed column classification.
    Lesellier E; West C
    J Chromatogr A; 2007 Jul; 1158(1-2):329-60. PubMed ID: 17467721
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Chromatographic behavior of packing materials for capillary electrochromatography with a coating of different immobilized polysiloxanes.
    Zhang G; Li Y; Fang Y; Han N; Xu B
    Electrophoresis; 2003 Feb; 24(4):693-9. PubMed ID: 12601740
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A new thermally immobilized fluorinated stationary phase for RP-HPLC.
    Maldaner L; Jardim IC
    J Sep Sci; 2010 Feb; 33(2):174-81. PubMed ID: 20087871
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Characterization of stationary phases in subcritical fluid chromatography by the solvation parameter model. I. Alkylsiloxane-bonded stationary phases.
    West C; Lesellier E
    J Chromatogr A; 2006 Mar; 1110(1-2):181-90. PubMed ID: 16487535
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Retention properties of novel beta-CD bonded stationary phases in reversed-phase HPLC mode.
    Zhao Y; Guo Z; Zhang Y; Xue X; Xu Q; Li X; Liang X; Zhang Y
    Talanta; 2009 May; 78(3):916-21. PubMed ID: 19269450
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Molecular shape selectivity through multiple carbonyl-pi interactions with noncrystalline solid phase for RP-HPLC.
    Rahman MM; Takafuji M; Ansarian HR; Ihara H
    Anal Chem; 2005 Oct; 77(20):6671-81. PubMed ID: 16223255
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of retention on traditional alkyl, polar endcapped, and polar embedded group stationary phases.
    Coym JW
    J Sep Sci; 2008 Jun; 31(10):1712-8. PubMed ID: 18461637
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Trigonal tricationic ionic liquids: a generation of gas chromatographic stationary phases.
    Payagala T; Zhang Y; Wanigasekara E; Huang K; Breitbach ZS; Sharma PS; Sidisky LM; Armstrong DW
    Anal Chem; 2009 Jan; 81(1):160-73. PubMed ID: 19067539
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.