These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

199 related articles for article (PubMed ID: 21039856)

  • 1. Delayed surgical retrieval of retained guidewire following percutaneous coronary intervention.
    Modi A; Zorinas A; Vohra HA; Kaarne M
    J Card Surg; 2011 Jan; 26(1):46-8. PubMed ID: 21039856
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Device entrapment: a rare complication of percutaneous coronary intervention.
    Rehman A; Khan JA; Sial JA; Baloch ZH
    J Coll Physicians Surg Pak; 2011 Oct; 21(10):620-2. PubMed ID: 22015124
    [TBL] [Abstract][Full Text] [Related]  

  • 3. How should I treat a patient to remove a fractured jailed side branch wire?
    Owens CG; Spence MS
    EuroIntervention; 2011 Aug; 7(4):520-7. PubMed ID: 21764672
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Troubleshooting and treating the balloon that fails to deflate.
    Gilchrist IC
    Catheter Cardiovasc Interv; 2011 Jan; 77(1):62. PubMed ID: 21181971
    [No Abstract]   [Full Text] [Related]  

  • 5. Intracoronary guidewire emboli: a unique complication and retrieval of the wire.
    Demircan S; Yazici M; Durna K; Yasar E
    Cardiovasc Revasc Med; 2008; 9(4):278-80. PubMed ID: 18928955
    [TBL] [Abstract][Full Text] [Related]  

  • 6. AngioSculpt PTCA Balloon Catheter entrapment and detachment managed with stent jailing.
    Pappy R; Gautam A; Abu-Fadel MS
    J Invasive Cardiol; 2010 Oct; 22(10):E208-10. PubMed ID: 20944201
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Entrapped coronary angioplasty stent balloon due to nondeflation: percutaneous retrieval by a simple technique.
    Girish MP; Gupta MD; Tyagi S
    Catheter Cardiovasc Interv; 2011 Jan; 77(1):58-61. PubMed ID: 20506291
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Frequency, treatment, and consequences of device loss and entrapment in contemporary percutaneous coronary interventions.
    Iturbe JM; Abdel-Karim AR; Papayannis A; Mahmood A; Rangan BV; Banerjee S; Brilakis ES
    J Invasive Cardiol; 2012 May; 24(5):215-21. PubMed ID: 22562915
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A rare instructive complication of balloon catheter fracture during percutaneous coronary intervention.
    Nomura T; Higuchi Y; Kato T; Keira N; Tatsumi T
    Cardiovasc Interv Ther; 2016 Jan; 31(1):70-4. PubMed ID: 25708708
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Consequences and treatment of guidewire entrapment and fracture during percutaneous coronary intervention.
    Danek BA; Karatasakis A; Brilakis ES
    Cardiovasc Revasc Med; 2016 Mar; 17(2):129-33. PubMed ID: 26826011
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Coronary artery aneurysms after drug-eluting stent implantation.
    Koniari I; Koletti B; Apostolakis E
    Interact Cardiovasc Thorac Surg; 2011 Apr; 12(4):638. PubMed ID: 21429891
    [No Abstract]   [Full Text] [Related]  

  • 12. Surgical retrieval of entrapped coronary angioplasty guidewire from the aorta.
    Ahmad T; Chithiraichelvan S; Patil TA; Jawali V
    Asian Cardiovasc Thorac Ann; 2016 Jan; 24(1):81-4. PubMed ID: 25069851
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Percutaneous evacuation of detached hydrophilic coating of jailed guidewire.
    Pawlowski K; Dorniak W; Klaudel J
    J Invasive Cardiol; 2010 Nov; 22(11):E193-5. PubMed ID: 21041863
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Successful transradial retrieval of broken catheter fragment during transradial coronary angiography.
    Kim JH; Kim GH; Moon KW
    J Invasive Cardiol; 2012 Feb; 24(2):74-5. PubMed ID: 22294538
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Successful fenestration using a chronic total occlusion-dedicated guidewire in a patient with catheter-induced dissection of the right coronary artery.
    Taniguchi N; Takahashi A; Sakamoto S
    J Invasive Cardiol; 2011 Feb; 23(2):84-6. PubMed ID: 21297207
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Proximal balloon deflation technique: a novel method to retrieve retained or entrapped equipment from the coronary system.
    Ashikaga T; Inagaki H; Satoh Y; Isobe M
    Cardiovasc Revasc Med; 2012; 13(4):253-5. PubMed ID: 22591764
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Successful retrieval of a frayed coronary stent using the peripheral crossover technique.
    Prasad A; Ilapakurti M; Ravandi A
    J Invasive Cardiol; 2011 Apr; 23(4):E69-71. PubMed ID: 21474855
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Surgical removal of entrapped and broken percutaneous transluminal coronary angioplasty balloon catheter.
    Singh J; Thingnam SK; Das D; Singh H; Sharma R; Vijayvergia R
    Interact Cardiovasc Thorac Surg; 2007 Feb; 6(1):94-6. PubMed ID: 17669780
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Entrapped devices after PCI.
    Alomari I; Snider R; Ponce S; Ahmed B
    Cardiovasc Revasc Med; 2014 Apr; 15(3):182-5. PubMed ID: 24268640
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Longitudinal stent elongation during retraction of entrapped jailed guidewire in a side branch with balloon catheter support: a case report.
    Taniguchi N; Mizuguchi Y; Takahashi A
    Cardiovasc Revasc Med; 2015; 16(1):52-4. PubMed ID: 24972514
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.