These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

88 related articles for article (PubMed ID: 21041134)

  • 1. Density imaging using a multiple-frequency DBIM approach.
    Lavarello R; Oelze M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Nov; 57(11):2471-9. PubMed ID: 21041134
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Density imaging using inverse scattering.
    Lavarello RJ; Oelze ML
    J Acoust Soc Am; 2009 Feb; 125(2):793-802. PubMed ID: 19206857
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Tomographic reconstruction of three-dimensional volumes using the distorted born iterative method.
    Lavarello RJ; Oelze ML
    IEEE Trans Med Imaging; 2009 Oct; 28(10):1643-53. PubMed ID: 19574162
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A study on the reconstruction of moderate contrast targets using the distorted born iterative method.
    Lavarello R; Oelze M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Jan; 55(1):112-24. PubMed ID: 18334318
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Tomographic density imaging using modified DF-DBIM approach.
    Huy TQ; Cuc NT; Nguyen VD; Long TT; Tan TD
    Biomed Eng Lett; 2019 Nov; 9(4):449-465. PubMed ID: 31799014
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fast 3D iterative image reconstruction for SPECT with rotating slat collimators.
    Holen RV; Vandenberghe S; Staelens S; De Beenhouwer J; Lemahieu I
    Phys Med Biol; 2009 Feb; 54(3):715-29. PubMed ID: 19131666
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Microwave medical imaging based on sparsity and an iterative method with adaptive thresholding.
    Azghani M; Kosmas P; Marvasti F
    IEEE Trans Med Imaging; 2015 Feb; 34(2):357-65. PubMed ID: 25252275
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reconstructions of chest phantoms by the D-bar method for electrical impedance tomography.
    Isaacson D; Mueller JL; Newell JC; Siltanen S
    IEEE Trans Med Imaging; 2004 Jul; 23(7):821-8. PubMed ID: 15250634
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Scattering by an arrangement of eccentric cylinders embedded on a coated cylinder with applications to tomographic density imaging.
    Lavarello RJ; Oelze ML
    J Acoust Soc Am; 2010 Feb; 127(2):645-8. PubMed ID: 20136184
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reconstruction quality and spectral content of an electromagnetic time-domain inversion algorithm.
    Fhager A; Hashemzadeh P; Persson M
    IEEE Trans Biomed Eng; 2006 Aug; 53(8):1594-604. PubMed ID: 16916094
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Regularized reconstruction in electrical impedance tomography using a variance uniformization constraint.
    Cohen-Bacrie C; Goussard Y; Guardo R
    IEEE Trans Med Imaging; 1997 Oct; 16(5):562-71. PubMed ID: 9368111
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Experimental Validation of Microwave Tomographywith the DBIM-TwIST Algorithm for Brain StrokeDetection and Classification.
    Karadima O; Rahman M; Sotiriou I; Ghavami N; Lu P; Ahsan S; Kosmas P
    Sensors (Basel); 2020 Feb; 20(3):. PubMed ID: 32033241
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Deterministic compressive sampling for high-quality image reconstruction of ultrasound tomography.
    Huy TQ; Tue HH; Long TT; Duc-Tan T
    BMC Med Imaging; 2017 May; 17(1):34. PubMed ID: 28545406
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Acceleration of optoacoustic model-based reconstruction using angular image discretization.
    Dean-Ben XL; Ntziachristos V; Razansky D
    IEEE Trans Med Imaging; 2012 May; 31(5):1154-62. PubMed ID: 22333989
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fast EM-like methods for maximum "a posteriori" estimates in emission tomography.
    de Pierro AR; Beleza Yamagishi ME
    IEEE Trans Med Imaging; 2001 Apr; 20(4):280-8. PubMed ID: 11370895
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Image reconstruction with acoustic measurement using distorted Born iteration method.
    Lu C; Lin J; Chew W; Otto G
    Ultrason Imaging; 1996 Apr; 18(2):140-56. PubMed ID: 8813032
    [TBL] [Abstract][Full Text] [Related]  

  • 17. On a limited-view reconstruction problem in diffraction tomography.
    Pan X; Anastasio MA
    IEEE Trans Med Imaging; 2002 Apr; 21(4):413-6. PubMed ID: 12022629
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Design and Experimental Validation of a Multiple-Frequency Microwave Tomography System Employing the DBIM-TwIST Algorithm.
    Ahsan S; Guo Z; Miao Z; Sotiriou I; Koutsoupidou M; Kallos E; Palikaras G; Kosmas P
    Sensors (Basel); 2018 Oct; 18(10):. PubMed ID: 30332843
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Digital image elasto-tomography: combinatorial and hybrid optimization algorithms for shape-based elastic property reconstruction.
    Peters A; Chase JG; Van Houten EE
    IEEE Trans Biomed Eng; 2008 Nov; 55(11):2575-83. PubMed ID: 18990627
    [TBL] [Abstract][Full Text] [Related]  

  • 20. 2D D-bar reconstructions of human chest and tank data using an improved approximation to the scattering transform.
    DeAngelo M; Mueller JL
    Physiol Meas; 2010 Feb; 31(2):221-32. PubMed ID: 20057005
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.