These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

212 related articles for article (PubMed ID: 21042)

  • 1. Activity and interference effects in measurement of ionized calcium with ion-selective electrodes.
    Grima JM; Brand MJ
    Clin Chem; 1977 Nov; 23(11):2048-54. PubMed ID: 21042
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ion effects in measurement of ionized calcium with a calcium-selective electrode.
    Kaufman RA; Tietz NW
    Clin Chem; 1980 Apr; 26(5):640-4. PubMed ID: 6266696
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ionized calcium in normal serum, ultrafiltrates, and whole blood determined by ion-exchange electrodes.
    Moore EW
    J Clin Invest; 1970 Feb; 49(2):318-34. PubMed ID: 4983663
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Calibration of ion-selective electrodes for use in biological fluids.
    Mohan MS; Bates RG
    Clin Chem; 1975 Jun; 21(7):864-72. PubMed ID: 236844
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ionized calcium in human milk determined with a calcium-selective electrode.
    Allen JC; Neville MC
    Clin Chem; 1983 May; 29(5):858-61. PubMed ID: 6839467
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Factors affecting the determination of ionized calcium in blood.
    Brauman J; Delvigne C; Deconinck I; Willems D
    Scand J Clin Lab Invest Suppl; 1983; 165():27-31. PubMed ID: 6578571
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Determination of electrolytes in serum and plasma].
    Külpmann WR
    Wien Klin Wochenschr Suppl; 1992; 192():37-41. PubMed ID: 1502823
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measurement of ionized magnesium with AVL 988/4 electrolyte analyzer: preliminary analytical and clinical results.
    Zoppi F; De Gasperi A; Guagnellini E; Marocchi A; Mineo E; Pazzucconi F; Rossi C; Turrini D
    Scand J Clin Lab Invest Suppl; 1996; 224():259-74. PubMed ID: 8865442
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of pH and NaCl on measurements of ionized calcium in matrices of serum and human albumin with a new calcium-selective electrode.
    Rehfeld SJ; Barkeley J; Loken HF
    Clin Chem; 1984 Feb; 30(2):304-7. PubMed ID: 6692542
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dependence of measured ionized calcium on protein concentration as measured by three ion-selective electrodes.
    McEnroe E; McKenna MJ; Diamond D; Covington AK; Freaney R
    Ann Clin Biochem; 1992 Jul; 29 ( Pt 4)():443-9. PubMed ID: 1642453
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Interferent ion effects on the Orion SS-20 Calcium Ion Analyser.
    Vadgama P; Mitchison J; Covington AK; Alberti KG
    Clin Chim Acta; 1982 Mar; 119(3):249-56. PubMed ID: 7067123
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Selectivity coefficients of ion-selective magnesium electrodes used for simultaneous determination of magnesium and calcium ions.
    Maj-Zurawska M; Lewenstam A
    Talanta; 2011 Dec; 87():295-301. PubMed ID: 22099682
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Neutral ionophore-based selective electrode for assaying the activity of magnesium in undiluted blood serum.
    Rouilly M; Rusterholz B; Spichiger UE; Simon W
    Clin Chem; 1990 Mar; 36(3):466-9. PubMed ID: 2311214
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of a new semiautomatic electrode system for simultaneous measurement of ionized calcium and pH.
    Thode J; Wandrup J; Aas F; Siggaard-Andersen O
    Scand J Clin Lab Invest; 1982 Sep; 42(5):407-15. PubMed ID: 7156853
    [TBL] [Abstract][Full Text] [Related]  

  • 15. IFCC recommended reference method for the determination of the substance concentration of ionized calcium in undiluted serum, plasma or whole blood.
    Burnett RW; Christiansen TF; Covington AK; Fogh-Andersen N; Külpmann WR; Lewenstam A; Maas AHJ ; Müller-Plathe O; Sachs C; Andersen OS; VanKessel AL; Zijlstra WG;
    Clin Chem Lab Med; 2000 Dec; 38(12):1301-14. PubMed ID: 11205698
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Analytical evaluation of Kone Microlyte determination of ionized magnesium.
    van Ingen HE; Huijgen HJ; Kok WT; Sanders GT
    Clin Chem; 1994 Jan; 40(1):52-5. PubMed ID: 8287544
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of a new automatic calcium ion analyzer.
    Madsen S; Olgaard K
    Clin Chem; 1977; 23(4):690-4. PubMed ID: 14794
    [TBL] [Abstract][Full Text] [Related]  

  • 18. IFCC guideline for sampling, measuring and reporting ionized magnesium in plasma.
    Ben Rayana MC; Burnett RW; Covington AK; D'Orazio P; Fogh-Andersen N; Jacobs E; Külpmann WR; Kuwa K; Larsson L; Lewenstam A; Maas AH; Mager G; Naskalski JW; Okorodudu AO; Ritter C; St John A; ;
    Clin Chem Lab Med; 2008; 46(1):21-6. PubMed ID: 17663628
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of an ion-selective electrolyte analyzer: Microlyte 6.
    Markova V; Sirakova I; Tsvetkova T; Nikolov R
    Folia Med (Plovdiv); 1997; 39(1):34-8. PubMed ID: 9141789
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Protein interference with ion-selective electrode measurement depends on reference electrode composition and design.
    Payne RB; Buckley BM; Rawson KM
    Ann Clin Biochem; 1991 Jan; 28 ( Pt 1)():68-72. PubMed ID: 2024938
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.