These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

336 related articles for article (PubMed ID: 21044856)

  • 21. Design and performance study of an orthopaedic surgery robotized module for automatic bone drilling.
    Boiadjiev G; Kastelov R; Boiadjiev T; Kotev V; Delchev K; Zagurski K; Vitkov V
    Int J Med Robot; 2013 Dec; 9(4):455-63. PubMed ID: 23441029
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Surface quality and pullout strength of ultrasonically-assisted drilling cortical bone.
    Hu Y; Fan Z; Zhang H; Zhang C; Fu W
    Proc Inst Mech Eng H; 2021 Apr; 235(4):378-388. PubMed ID: 33356906
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Improved accuracy of navigated drilling using a drill alignment device.
    Kendoff D; Citak M; Gardner MJ; Stübig T; Krettek C; Hüfner T
    J Orthop Res; 2007 Jul; 25(7):951-7. PubMed ID: 17415775
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Bone drilling haptic interaction for orthopedic surgical simulator.
    Tsai MD; Hsieh MS; Tsai CH
    Comput Biol Med; 2007 Dec; 37(12):1709-18. PubMed ID: 17568576
    [TBL] [Abstract][Full Text] [Related]  

  • 25. On the development of a new flexible drill for orthopedic surgery and the forces experienced on drilling bovine bone.
    Ahmad Fuad ANB; Deep K; Yao W; Rowe P
    Proc Inst Mech Eng H; 2018 May; 232(5):502-507. PubMed ID: 29543120
    [TBL] [Abstract][Full Text] [Related]  

  • 26. An experimental investigation on thermal exposure during bone drilling.
    Lee J; Ozdoganlar OB; Rabin Y
    Med Eng Phys; 2012 Dec; 34(10):1510-20. PubMed ID: 22483188
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Experimental investigations and finite element simulation of cutting heat in vibrational and conventional drilling of cortical bone.
    Wang Y; Cao M; Zhao X; Zhu G; McClean C; Zhao Y; Fan Y
    Med Eng Phys; 2014 Nov; 36(11):1408-15. PubMed ID: 24908355
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effects of various drilling parameters on bone during implantology: An in vitro experimental study.
    Karaca F; Aksakal B
    Acta Bioeng Biomech; 2013; 15(4):25-32. PubMed ID: 24479623
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Biomechanical measurements of surgical drilling force and torque in human versus artificial femurs.
    MacAvelia T; Salahi M; Olsen M; Crookshank M; Schemitsch EH; Ghasempoor A; Janabi-Sharifi F; Zdero R
    J Biomech Eng; 2012 Dec; 134(12):124503. PubMed ID: 23363210
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Experimental investigation of the temperature elevation in bone drilling using conventional and vibration-assisted methods.
    Bai X; Hou S; Li K; Qu Y; Zhang T
    Med Eng Phys; 2019 Jul; 69():1-7. PubMed ID: 31229386
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Notched K-wire for low thermal damage bone drilling.
    Liu Y; Belmont B; Wang Y; Tai B; Holmes J; Shih A
    Med Eng Phys; 2017 Jul; 45():25-33. PubMed ID: 28462826
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Temperature rise during drilling through bone.
    Abouzgia MB; James DF
    Int J Oral Maxillofac Implants; 1997; 12(3):342-53. PubMed ID: 9197099
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Using an admittance algorithm for bone drilling procedures.
    Accini F; Díaz I; Gil JJ
    Comput Methods Programs Biomed; 2016 Jan; 123():150-8. PubMed ID: 26516110
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Experimental investigation on the effect of drill quality on the performance of bone drilling.
    Alam K; Piya S; Al-Ghaithi A; Silberschmidth V
    Biomed Tech (Berl); 2020 Jan; 65(1):113-120. PubMed ID: 31437122
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparative Analysis of Cutting Forces, Torques, and Vibration in Drilling of Bovine, Porcine, and Artificial Femur Bone with Considerations for Robot Effector Stiffness.
    Orelaja OA; Wang X; Shen D; Ibrahim DS; Zhao T; Sharif U; Afiz IA
    J Healthc Eng; 2020; 2020():8817422. PubMed ID: 33133473
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Suitability of three saws for minimally invasive bone cutting.
    Kong C; Trejos AL; Naish MD; Patel RV; Leitch KK
    Surg Innov; 2010 Mar; 17(1):5-10. PubMed ID: 20034976
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Drilling of bone: a robust automatic method for the detection of drill bit break-through.
    Ong FR; Bouazza-Marouf K
    Proc Inst Mech Eng H; 1998; 212(3):209-21. PubMed ID: 9695640
    [TBL] [Abstract][Full Text] [Related]  

  • 38. How to adapt an ordinary drilling machine for orthopaedic surgery.
    Musa AA
    West Afr J Med; 2002; 21(1):59. PubMed ID: 12081347
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Experimental and numerical investigation of cracking behavior of cortical bone in cutting.
    Alam K
    Technol Health Care; 2014; 22(5):741-50. PubMed ID: 25097063
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Parameters affecting mechanical and thermal responses in bone drilling: A review.
    Lee J; Chavez CL; Park J
    J Biomech; 2018 Apr; 71():4-21. PubMed ID: 29559242
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 17.