137 related articles for article (PubMed ID: 21046000)
1. Mechanical failure of the long gamma nail in two proximal femur fractures.
Najibi S; Mark L; Fehnel D
Iowa Orthop J; 2010; 30():205-10. PubMed ID: 21046000
[TBL] [Abstract][Full Text] [Related]
2. Comparison of compression hip screw and gamma nail for treatment of peritrochanteric fractures.
Bess RJ; Jolly SA
J South Orthop Assoc; 1997; 6(3):173-9. PubMed ID: 9322196
[TBL] [Abstract][Full Text] [Related]
3. Failure of femoral nailing in the elderly.
Harrington P; Sharif I; Smyth H
Arch Orthop Trauma Surg; 1997; 116(4):244-5. PubMed ID: 9128783
[TBL] [Abstract][Full Text] [Related]
4. Cephalomedullary screws as the standard proximal locking screws for nailing femoral shaft fractures.
Collinge C; Liporace F; Koval K; Gilbert GT
J Orthop Trauma; 2010 Dec; 24(12):717-22. PubMed ID: 21076246
[TBL] [Abstract][Full Text] [Related]
5. The early failure of the gamma nail and the dynamic hip screw in femurs with a wide medullary canal. A biomechanical study of intertrochanteric fractures.
Ceynowa M; Zerdzicki K; Klosowski P; Pankowski R; Rocławski M; Mazurek T
Clin Biomech (Bristol, Avon); 2020 Jan; 71():201-207. PubMed ID: 31775090
[TBL] [Abstract][Full Text] [Related]
6. The effect of implant overlap on the mechanical properties of the femur.
Harris T; Ruth JT; Szivek J; Haywood B
J Trauma; 2003 May; 54(5):930-5. PubMed ID: 12777906
[TBL] [Abstract][Full Text] [Related]
7. Fractured Gamma nail.
Zafiropoulos G; Pratt DJ
Injury; 1994 Jul; 25(5):331-6. PubMed ID: 8034355
[No Abstract] [Full Text] [Related]
8. Internal fixation of proximal femur fractures: a biomechanical comparison of the Gamma Locking Nail and the Omega Compression Hip Screw.
Shaw JA; Wilson S
Orthop Rev; 1993 Jan; 22(1):61-8. PubMed ID: 8421636
[TBL] [Abstract][Full Text] [Related]
9. Rotationally Stable Screw-Anchor With Locked Trochanteric Stabilizing Plate Versus Proximal Femoral Nail Antirotation in the Treatment of AO/OTA 31A2.2 Fracture: A Biomechanical Evaluation.
Knobe M; Nagel P; Maier KJ; Gradl G; Buecking B; Sönmez TT; Modabber A; Prescher A; Pape HC
J Orthop Trauma; 2016 Jan; 30(1):e12-8. PubMed ID: 26849388
[TBL] [Abstract][Full Text] [Related]
10. Fatigue fracture of the interlocking nail in the treatment of fractures of the distal part of the femoral shaft.
Bucholz RW; Ross SE; Lawrence KL
J Bone Joint Surg Am; 1987 Dec; 69(9):1391-9. PubMed ID: 3440797
[TBL] [Abstract][Full Text] [Related]
11. Mechanical study of the safe distance between distal femoral fracture site and distal locking screws in antegrade intramedullary nailing.
Antekeier SB; Burden RL; Voor MJ; Roberts CS
J Orthop Trauma; 2005; 19(10):693-7. PubMed ID: 16314716
[TBL] [Abstract][Full Text] [Related]
12. Angle stable nails provide improved healing for a complex fracture model in the femur.
Kubacki MR; Verioti CA; Patel SD; Garlock AN; Fernandez D; Atkinson PJ
Clin Orthop Relat Res; 2014 Apr; 472(4):1300-9. PubMed ID: 24048888
[TBL] [Abstract][Full Text] [Related]
13. [Impaired Healing after Surgery for Femoral Fractures].
Šmejkal K; Lochman P; Trlica J; Novotný P; Šimek J; Dědek T
Acta Chir Orthop Traumatol Cech; 2015; 82(5):358-63. PubMed ID: 26516951
[TBL] [Abstract][Full Text] [Related]
14. Comparative endurance testing of the Biomet Matthews Nail and the dynamic compression screw, in simulated condylar and supracondylar femoral fractures.
O'Connor-Read LM; Davidson JA; Davies BM; Matthews MG; Smirthwaite P
Biomed Eng Online; 2008 Jan; 7():3. PubMed ID: 18208608
[TBL] [Abstract][Full Text] [Related]
15. A comparison of the long gamma nail with the sliding hip screw for the treatment of AO/OTA 31-A2 fractures of the proximal part of the femur: a prospective randomized trial.
Barton TM; Gleeson R; Topliss C; Greenwood R; Harries WJ; Chesser TJ
J Bone Joint Surg Am; 2010 Apr; 92(4):792-8. PubMed ID: 20360500
[TBL] [Abstract][Full Text] [Related]
16. Influence of screw combination and nail materials in the stability of anterograde reamed intramedullary nail in distal femoral fractures.
Gabarre S; Albareda J; Gracia L; Puértolas S; Ibarz E; Herrera A
Injury; 2017 Nov; 48 Suppl 6():S47-S53. PubMed ID: 29162241
[TBL] [Abstract][Full Text] [Related]
17. [Proximal femoral fractures: fixation and nailing. Role of an implant fixed with a femoral head screw and nailing of the femoral diaphysis in per- and subtrochanteric fractures--results in a consecutive series of 28 Gamma long nails].
Chevalley F
Rev Med Suisse Romande; 1996 Jan; 116(1):65-70. PubMed ID: 8871277
[No Abstract] [Full Text] [Related]
18. Intramedullary locking nails for femoral shaft fractures in elderly patients.
Moran CG; Gibson MJ; Cross AT
J Bone Joint Surg Br; 1990 Jan; 72(1):19-22. PubMed ID: 2298787
[TBL] [Abstract][Full Text] [Related]
19. Biomechanical analysis of the mechanism of interlocking nail failure.
Wu CC; Shih CH
Arch Orthop Trauma Surg; 1992; 111(5):268-72. PubMed ID: 1389779
[TBL] [Abstract][Full Text] [Related]
20. The retrograde nail for distal femoral fractures in the elderly: high failure rate of the condyle screw and nut.
Singh SK; El-Gendy KA; Chikkamuniyappa C; Houshian S
Injury; 2006 Oct; 37(10):1004-10. PubMed ID: 16499912
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]