These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
111 related articles for article (PubMed ID: 21048512)
1. Variability in the calibration error of the goldmann applanation tonometer. Choudhari NS; Jadhav V; George R; Vijaya L J Glaucoma; 2011 Oct; 20(8):492-6. PubMed ID: 21048512 [TBL] [Abstract][Full Text] [Related]
2. Measurement of Goldmann applanation tonometer calibration error. Choudhari NS; George R; Baskaran M; Vijaya L; Dudeja N Ophthalmology; 2009 Jan; 116(1):3-8. PubMed ID: 18708256 [TBL] [Abstract][Full Text] [Related]
3. How Often the Goldmann Applanation Tonometer Should be Checked for Calibration Error? Choudhari NS; Rao HL; Ramavath S; Rekha G; Rao A; Senthil S; Garudadri CS J Glaucoma; 2016 Nov; 25(11):908-913. PubMed ID: 27755349 [TBL] [Abstract][Full Text] [Related]
4. The accuracy of continued clinical use of goldmann applanation tonometers with known calibration errors. Sandhu SS; Chattopadhyay S; Amariotakis GA; Skarmoutsos F; Birch MK; Ray-Chaudhuri N Ophthalmology; 2009 Jan; 116(1):9-13. PubMed ID: 18801579 [TBL] [Abstract][Full Text] [Related]
5. A Simplified (Screening) Approach to Check the Calibration Status of the Goldmann Applanation Tonometer. Choudhari NS; Ramavath S; Rekha G; Rao A; Rao HL; Senthil S; Garudadri CS J Glaucoma; 2016 Oct; 25(10):812-814. PubMed ID: 27136084 [TBL] [Abstract][Full Text] [Related]
6. Rectifying calibration error of Goldmann applanation tonometer is easy! Choudhari NS; Moorthy KP; Tungikar VB; Kumar M; George R; Rao HL; Senthil S; Vijaya L; Garudadri CS Indian J Ophthalmol; 2014 Nov; 62(11):1082-1085. PubMed ID: 25494251 [TBL] [Abstract][Full Text] [Related]
7. Frequency of goldmann applanation tonometer calibration error checks. Sandhu SS; Chattopadhyay S; Birch MK; Ray-Chaudhuri N J Glaucoma; 2005 Jun; 14(3):215-8. PubMed ID: 15870604 [TBL] [Abstract][Full Text] [Related]
8. Calibration errors of Goldmann tonometers in a tertiary eye care centre. Chuo JY; Mikelberg FS Can J Ophthalmol; 2007 Oct; 42(5):712-4. PubMed ID: 17891198 [TBL] [Abstract][Full Text] [Related]
9. Intraocular pressure measurement precision with the Goldmann applanation, dynamic contour, and ocular response analyzer tonometers. Kotecha A; White E; Schlottmann PG; Garway-Heath DF Ophthalmology; 2010 Apr; 117(4):730-7. PubMed ID: 20122737 [TBL] [Abstract][Full Text] [Related]
10. The Outcomes of a Comprehensive Program for Maintenance of Goldmann Applanation Tonometer. Choudhari NS; Richhariya A; Wadke V; Deshmukh SP; George R; Senthil S; Chandra Sekhar G J Glaucoma; 2019 Jun; 28(6):507-511. PubMed ID: 30950966 [TBL] [Abstract][Full Text] [Related]
11. The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry. Kotecha A; White ET; Shewry JM; Garway-Heath DF Br J Ophthalmol; 2005 Dec; 89(12):1572-5. PubMed ID: 16299132 [TBL] [Abstract][Full Text] [Related]
12. Clinical evaluation of applanation resonance tonometry: a comparison with Goldmann applanation tonometry. Hallberg P; Eklund A; Bäcklund T; Lindén C J Glaucoma; 2007 Jan; 16(1):88-93. PubMed ID: 17224756 [TBL] [Abstract][Full Text] [Related]
13. The validity of a digital eyelid tonometer (TGDc-01) and its comparison with Goldmann applanation tonometry - a pilot study. Lam AK; Lam CH; Chan R Ophthalmic Physiol Opt; 2005 May; 25(3):205-10. PubMed ID: 15854065 [TBL] [Abstract][Full Text] [Related]
14. Comparison of dynamic contour tonometry with goldmann applanation tonometry. Kaufmann C; Bachmann LM; Thiel MA Invest Ophthalmol Vis Sci; 2004 Sep; 45(9):3118-21. PubMed ID: 15326129 [TBL] [Abstract][Full Text] [Related]
15. Effect of laser in situ keratomileusis on rebound tonometry and Goldmann applanation tonometry. Lam AK; Wu R; Wang Z; Woo V; Chan E; Tam K; Chau R; Wong KK J Cataract Refract Surg; 2010 Apr; 36(4):631-6. PubMed ID: 20362856 [TBL] [Abstract][Full Text] [Related]
16. Performance of the rebound, noncontact and Goldmann applanation tonometers in routine clinical practice. Martinez-de-la-Casa JM; Jimenez-Santos M; Saenz-Frances F; Matilla-Rodero M; Mendez-Hernandez C; Herrero-Vanrell R; Garcia-Feijoo J Acta Ophthalmol; 2011 Nov; 89(7):676-80. PubMed ID: 19900196 [TBL] [Abstract][Full Text] [Related]
17. [A new site-independent tonometer (ProTon) in comparison with the Goldmann applanation tonometer]. Gräf M; Wassill H; Dick B Klin Monbl Augenheilkd; 1995 Apr; 206(4):255-61. PubMed ID: 7791286 [TBL] [Abstract][Full Text] [Related]
18. Assessment of a new Goldmann applanation tonometer. Egli M; Goldblum D; Kipfer A; Rohrer K; Tappeiner C; Abegg M; Berger L; Schoetzau A; Iliev ME Br J Ophthalmol; 2012 Jan; 96(1):42-6. PubMed ID: 21464035 [TBL] [Abstract][Full Text] [Related]
19. [The safety of metrological control of applanation tonometers by technical investigations on transfer standards]. Schwenteck T; Thiemich HJ Klin Monbl Augenheilkd; 2010 Jun; 227(6):489-95. PubMed ID: 20349398 [TBL] [Abstract][Full Text] [Related]
20. The Proview phosphene tonometer fails to measure ocular pressure accurately in clinical practice. Alvarez TL; Gollance SA; Thomas GA; Greene RJ; Marchetto PM; Moore EJ; Realini T; Liebmann JM; Ritch R; Lama P; Fechtner RD Ophthalmology; 2004 Jun; 111(6):1077-85. PubMed ID: 15177956 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]