264 related articles for article (PubMed ID: 21050721)
1. In vitro evaluation of insertion and removal torques of orthodontic mini-implants.
Pithon MM; Nojima MG; Nojima LI
Int J Oral Maxillofac Surg; 2011 Jan; 40(1):80-5. PubMed ID: 21050721
[TBL] [Abstract][Full Text] [Related]
2. Mechanical evaluation of orthodontic mini-implants of different lengths.
Pithon MM; Figueiredo DS; Oliveira DD
J Oral Maxillofac Surg; 2013 Mar; 71(3):479-86. PubMed ID: 23273488
[TBL] [Abstract][Full Text] [Related]
3. Factors affecting the long-term stability of orthodontic mini-implants.
Motoyoshi M; Uemura M; Ono A; Okazaki K; Shigeeda T; Shimizu N
Am J Orthod Dentofacial Orthop; 2010 May; 137(5):588.e1-5; discussion 588-9. PubMed ID: 20451776
[TBL] [Abstract][Full Text] [Related]
4. Impact of bone quality, implant type, and implantation site preparation on insertion torques of mini-implants used for orthodontic anchorage.
Wilmes B; Drescher D
Int J Oral Maxillofac Surg; 2011 Jul; 40(7):697-703. PubMed ID: 21458232
[TBL] [Abstract][Full Text] [Related]
5. A torque removal study on the primary stability of orthodontic titanium screw mini-implants in the cortical bone of dog femurs.
Okazaki J; Komasa Y; Sakai D; Kamada A; Ikeo T; Toda I; Suwa F; Inoue M; Etoh T
Int J Oral Maxillofac Surg; 2008 Jul; 37(7):647-50. PubMed ID: 18554870
[TBL] [Abstract][Full Text] [Related]
6. Fracture resistance of orthodontic mini-implants: a biomechanical in vitro study.
Wilmes B; Panayotidis A; Drescher D
Eur J Orthod; 2011 Aug; 33(4):396-401. PubMed ID: 21310766
[TBL] [Abstract][Full Text] [Related]
7. An in vitro investigation of peak insertion torque values of six commercially available mini-implants.
Whang CZ; Bister D; Sherriff M
Eur J Orthod; 2011 Dec; 33(6):660-6. PubMed ID: 21186241
[TBL] [Abstract][Full Text] [Related]
8. Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study.
Tabassum A; Meijer GJ; Wolke JG; Jansen JA
Clin Oral Implants Res; 2010 Feb; 21(2):213-20. PubMed ID: 20070754
[TBL] [Abstract][Full Text] [Related]
9. Removal torque values of surface-treated mini-implants after loading.
Kim SH; Cho JH; Chung KR; Kook YA; Nelson G
Am J Orthod Dentofacial Orthop; 2008 Jul; 134(1):36-43. PubMed ID: 18617101
[TBL] [Abstract][Full Text] [Related]
10. Microcomputed tomographic analysis of bone reaction at insertion of orthodontic mini-implants in sheep.
Rebaudi A; Laffi N; Benedicenti S; Angiero F; Romanos GE
Int J Oral Maxillofac Implants; 2011; 26(6):1233-40. PubMed ID: 22167428
[TBL] [Abstract][Full Text] [Related]
11. Primary stability and histomorphometric bone-implant contact of self-drilling and self-tapping orthodontic microimplants.
Çehreli S; Arman-Özçırpıcı A
Am J Orthod Dentofacial Orthop; 2012 Feb; 141(2):187-95. PubMed ID: 22284286
[TBL] [Abstract][Full Text] [Related]
12. Comparison of self-tapping and self-drilling orthodontic mini-implants: an animal study of insertion torque and displacement under lateral loading.
Su YY; Wilmes B; Hönscheid R; Drescher D
Int J Oral Maxillofac Implants; 2009; 24(3):404-11. PubMed ID: 19587861
[TBL] [Abstract][Full Text] [Related]
13. Effect of mini-implant length and diameter on primary stability under loading with two force levels.
Chatzigianni A; Keilig L; Reimann S; Eliades T; Bourauel C
Eur J Orthod; 2011 Aug; 33(4):381-7. PubMed ID: 21062964
[TBL] [Abstract][Full Text] [Related]
14. Effect of autoclaving on the fracture torque of mini-implants used for orthodontic anchorage.
Mattos CT; Ruellas AC; Sant'anna EF
J Orthod; 2011 Mar; 38(1):15-20. PubMed ID: 21367824
[TBL] [Abstract][Full Text] [Related]
15. The effect of miniscrew taper morphology on insertion and removal torque in dogs.
Cha JY; Takano-Yamamoto T; Hwang CJ
Int J Oral Maxillofac Implants; 2010; 25(4):777-83. PubMed ID: 20657874
[TBL] [Abstract][Full Text] [Related]
16. Horizontal pull-out strength of orthodontic infrazygomatic mini-implant: an in vitro study.
Chen CM; Wu JH; Lu PC; Wang HC; Lee HE; Wang CH; Du JK
Implant Dent; 2011 Apr; 20(2):139-45. PubMed ID: 21448023
[TBL] [Abstract][Full Text] [Related]
17. Influence of cortical thickness on the stability of mini-implants with microthreads.
Vilani GN; Ruellas AC; Mattos CT; Fernandes DJ; Elias CN
Braz Oral Res; 2015; 29():. PubMed ID: 25627887
[TBL] [Abstract][Full Text] [Related]
18. Sequential bone healing of immediately loaded mini-implants.
Serra G; Morais LS; Elias CN; Meyers MA; Andrade L; Muller C; Muller M
Am J Orthod Dentofacial Orthop; 2008 Jul; 134(1):44-52. PubMed ID: 18617102
[TBL] [Abstract][Full Text] [Related]
19. Fracture strength of orthodontic mini-implants.
Assad-Loss TF; Kitahara-Céia FMF; Silveira GS; Elias CN; Mucha JN
Dental Press J Orthod; 2017; 22(3):47-54. PubMed ID: 28746487
[TBL] [Abstract][Full Text] [Related]
20. Mini-implant behavior to shear tensile forces in the porcine mandible.
Edwards CW; Mah JK
World J Orthod; 2010; 11(4):362-8. PubMed ID: 21491003
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]