BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

223 related articles for article (PubMed ID: 21050971)

  • 1. Anatomic and procedural predictors of paravalvular aortic regurgitation after implantation of the Medtronic CoreValve bioprosthesis.
    Sherif MA; Abdel-Wahab M; Stöcker B; Geist V; Richardt D; Tölg R; Richardt G
    J Am Coll Cardiol; 2010 Nov; 56(20):1623-9. PubMed ID: 21050971
    [TBL] [Abstract][Full Text] [Related]  

  • 2. First trans-axillary implantation of Edwards Sapien valve to treat an incompetent aortic bioprosthesis.
    Sharp AS; Michev I; Colombo A
    Catheter Cardiovasc Interv; 2010 Mar; 75(4):507-10. PubMed ID: 20088013
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transcatheter aortic valve implantation for stenosed and regurgitant aortic valve bioprostheses CoreValve for failed bioprosthetic aortic valve replacements.
    Khawaja MZ; Haworth P; Ghuran A; Lee L; de Belder A; Hutchinson N; Trivedi U; Laborde JC; Hildick-Smith D
    J Am Coll Cardiol; 2010 Jan; 55(2):97-101. PubMed ID: 20117377
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Difficulties with horizontal aortic root in transcatheter aortic valve implantation.
    Chan PH; Alegria-Barrero E; Di Mario C
    Catheter Cardiovasc Interv; 2013 Mar; 81(4):630-5. PubMed ID: 22431290
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Aortic regurgitation index defines severity of peri-prosthetic regurgitation and predicts outcome in patients after transcatheter aortic valve implantation.
    Sinning JM; Hammerstingl C; Vasa-Nicotera M; Adenauer V; Lema Cachiguango SJ; Scheer AC; Hausen S; Sedaghat A; Ghanem A; Müller C; Grube E; Nickenig G; Werner N
    J Am Coll Cardiol; 2012 Mar; 59(13):1134-41. PubMed ID: 22440213
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transapical aortic valve implantation: incidence and predictors of paravalvular leakage and transvalvular regurgitation in a series of 358 patients.
    Unbehaun A; Pasic M; Dreysse S; Drews T; Kukucka M; Mladenow A; Ivanitskaja-Kühn E; Hetzer R; Buz S
    J Am Coll Cardiol; 2012 Jan; 59(3):211-21. PubMed ID: 22240125
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Successful reposition and treatment of severe aortic paraprosthetic regurgitation after percutaneous implantation of a self-expandable biological valve.
    Frerker C; Bergmann M; Schewel D; Busse C; Jensen F; Schmoeckel M; Schneider C; Kuck KH; Schaefer U
    J Cardiovasc Med (Hagerstown); 2012 May; 13(5):346-50. PubMed ID: 20479655
    [No Abstract]   [Full Text] [Related]  

  • 8. Predictors of 1-year mortality in patients with aortic regurgitation after transcatheter aortic valve implantation: an analysis from the multicentre German TAVI registry.
    Abdel-Wahab M; Zahn R; Gerckens U; Linke A; Sievert H; Schäfer U; Kahlert P; Hambrecht R; Sack S; Hoffmann E; Senges J; Schneider S; Richardt G;
    Heart; 2014 Aug; 100(16):1250-6. PubMed ID: 24895354
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Long-term outcome of patients with moderate and severe prosthetic aortic valve regurgitation after transcatheter aortic valve implantation.
    Gotzmann M; Korten M; Bojara W; Lindstaedt M; Rahlmann P; Mügge A; Ewers A
    Am J Cardiol; 2012 Nov; 110(10):1500-6. PubMed ID: 22863177
    [TBL] [Abstract][Full Text] [Related]  

  • 10. First percutaneous transcatheter aortic valve-in-valve implant with three year follow-up.
    Ruiz CE; Laborde JC; Condado JF; Chiam PT; Condado JA
    Catheter Cardiovasc Interv; 2008 Aug; 72(2):143-8. PubMed ID: 18655115
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Transcatheter valve-in-valve implantation for the treatment of stentless aortic valve dysfunction.
    Rodés-Cabau J; Dumont E; Doyle D; Lemieux J
    J Thorac Cardiovasc Surg; 2010 Jul; 140(1):246-8. PubMed ID: 19783014
    [No Abstract]   [Full Text] [Related]  

  • 12. Intraoperative 2D and 3D transoesophageal echocardiographic predictors of aortic regurgitation after transcatheter aortic valve implantation.
    Gripari P; Ewe SH; Fusini L; Muratori M; Ng AC; Cefalù C; Delgado V; Schalij MJ; Bax JJ; Marsan NA; Tamborini G; Pepi M
    Heart; 2012 Aug; 98(16):1229-36. PubMed ID: 22826560
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-Corevalve bioprosthesis.
    Jilaihawi H; Chin D; Spyt T; Jeilan M; Vasa-Nicotera M; Bence J; Logtens E; Kovac J
    Eur Heart J; 2010 Apr; 31(7):857-64. PubMed ID: 20037145
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Correction of aortic regurgitation after transcatheter aortic valve implantation of the Medtronic CoreValveTM prosthesis due to a too-low implantation, using transcatheter repositioning.
    Zahn R; Schiele R; Kilkowski C; Klein B; Zeymer U; Werling C; Lehmann A; Gerckens U; Saggau W
    J Heart Valve Dis; 2011 Jan; 20(1):64-9. PubMed ID: 21404899
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Treatment and prevention of aortic regurgitation after transcatheter aortic valve implantation.
    Hayashida K; Lefèvre T
    EuroIntervention; 2012 Sep; 8 Suppl Q():Q34-40. PubMed ID: 22995110
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of two- and three-dimensional transthoracic echocardiography to cardiac magnetic resonance imaging for assessment of paravalvular regurgitation after transcatheter aortic valve implantation.
    Altiok E; Frick M; Meyer CG; Al Ateah G; Napp A; Kirschfink A; Almalla M; Lotfi S; Becker M; Herich L; Lehmacher W; Hoffmann R
    Am J Cardiol; 2014 Jun; 113(11):1859-66. PubMed ID: 24837265
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Haemodynamic evaluation of aortic regurgitation after transcatheter aortic valve implantation using cardiovascular magnetic resonance.
    Sherif MA; Abdel-Wahab M; Beurich HW; Stöcker B; Zachow D; Geist V; Tölg R; Richardt G
    EuroIntervention; 2011 May; 7(1):57-63. PubMed ID: 21550904
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Imaging and quantification of aortic regurgitation after TAVI.
    Ewe SH; Delgado V; Bax JJ
    EuroIntervention; 2012 Sep; 8 Suppl Q():Q21-30. PubMed ID: 22995108
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Severe intraprosthetic regurgitation and valve embolization after transcatheter aortic valve implantation.
    Ben-Dor I; Satler LF; Pichard AD; Waksman R
    Catheter Cardiovasc Interv; 2013 Feb; 81(2):392-6. PubMed ID: 22566389
    [TBL] [Abstract][Full Text] [Related]  

  • 20. From pressure overload to volume overload: aortic regurgitation after transcatheter aortic valve implantation.
    Gotzmann M; Lindstaedt M; Mügge A
    Am Heart J; 2012 Jun; 163(6):903-11. PubMed ID: 22709742
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.