These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

304 related articles for article (PubMed ID: 21052189)

  • 1. High-accuracy spectrometer for measurement of regular spectral transmittance.
    Manoochehri F; Ikonen E
    Appl Opt; 1995 Jul; 34(19):3686-92. PubMed ID: 21052189
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Design and testing of a new high-accuracy ultraviolet-visible-near-infrared spectrophotometer.
    Zwinkels JC; Gignac DS
    Appl Opt; 1992 Apr; 31(10):1557-67. PubMed ID: 20720790
    [TBL] [Abstract][Full Text] [Related]  

  • 3. New reference spectrophotometer.
    Mielenz KD; Eckerle KL; Madden RP; Reader J
    Appl Opt; 1973 Jul; 12(7):1630-41. PubMed ID: 20125575
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurement Assurance Program Transmittance Standards for Spectrophotometric Linearity Testing: Preparation and Calibration.
    Eckerle KL; Weidner VR; Hsia JJ; Kafadar K
    J Res Natl Bur Stand (1977); 1983; 88(1):25-36. PubMed ID: 34566095
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Design and testing of a two-monochromator reference spectrofluorimeter for high-accuracy total radiance factor measurements.
    Zwinkels JC; Gignac DS; Nevins M; Powell I; Bewsher A
    Appl Opt; 1997 Feb; 36(4):892-902. PubMed ID: 18250755
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Complete theoretical treatment of the transmittance ratio ultraviolet/visible spectrophotometric stray radiant energy test method.
    Fleming P
    Appl Spectrosc; 2009 Oct; 63(10):1128-33. PubMed ID: 19843363
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Fourier transform spectrometer without a beam splitter for the vacuum ultraviolet range: From the optical design to the first UV spectrum.
    de Oliveira N; Joyeux D; Phalippou D; Rodier JC; Polack F; Vervloet M; Nahon L
    Rev Sci Instrum; 2009 Apr; 80(4):043101. PubMed ID: 19405645
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Multiple-integrating sphere spectrophotometer for measuring absolute spectral reflectance and transmittance.
    Zerlaut GA; Anderson TE
    Appl Opt; 1981 Nov; 20(21):3797-804. PubMed ID: 20372262
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Automatic recording spectroradiometer system.
    Heaps WL
    Appl Opt; 1971 Sep; 10(9):2045-59. PubMed ID: 20111268
    [TBL] [Abstract][Full Text] [Related]  

  • 10. NBS reference hazemeter: its development and testing.
    Weidner VR; Hsia JJ
    Appl Opt; 1979 May; 18(10):1619-26. PubMed ID: 20212902
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measurement of normalized spectral responsivity of digital imaging devices by using a LED-based tunable uniform source.
    Mahmoud K; Park S; Park SN; Lee DH
    Appl Opt; 2013 Feb; 52(6):1263-71. PubMed ID: 23434998
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Spectral Transmittance Characteristics of Holmium Oxide in Perchloric Acid Solution.
    Weidner VR; Mavrodineanu R; Mielenz KD; Velapoldi RA; Eckerle KL; Adams B
    J Res Natl Bur Stand (1977); 1985; 90(2):115-125. PubMed ID: 34566147
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Accurate infrared transmittance measurements on optical filters using an FT-IR spectrometer.
    Compton DA; Drab J; Barr HS
    Appl Opt; 1990 Jul; 29(19):2908-12. PubMed ID: 20567350
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Qualification of a fluorescence spectrometer for measuring true fluorescence spectra.
    DeRose PC; Early EA; Kramer GW
    Rev Sci Instrum; 2007 Mar; 78(3):033107. PubMed ID: 17411178
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical ultraviolet dosimetry with a CCD monochromator array spectroradiometer.
    Coleman A; Sarkany R; Walker S
    Phys Med Biol; 2008 Sep; 53(18):5239-55. PubMed ID: 18728310
    [TBL] [Abstract][Full Text] [Related]  

  • 16. NBS specular reflectometer-spectrophotometer.
    Weidner VR; Hsia JJ
    Appl Opt; 1980 Apr; 19(8):1268-73. PubMed ID: 20221025
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of correction factors for transmittance measurements in single-beam integrating spheres.
    Grandin K; Roos A
    Appl Opt; 1994 Sep; 33(25):6098-104. PubMed ID: 20936027
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Automated high precision variable aperture for spectrophotometer linearity testing.
    Zwinkels JC; Gignac DS
    Appl Opt; 1991 May; 30(13):1678-87. PubMed ID: 20700343
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of transmission and reflection modalities for measuring content uniformity of pharmaceutical tablets with near-infrared spectroscopy.
    Xiang D; LoBrutto R; Cheney J; Wabuyele BW; Berry J; Lyon R; Wu H; Khan MA; Hussain AS
    Appl Spectrosc; 2009 Jan; 63(1):33-47. PubMed ID: 19146717
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Longterm changes of silicon photodiodes and their use for photometric standardization.
    Eppeldauer G
    Appl Opt; 1990 May; 29(15):2289-94. PubMed ID: 20563163
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.