These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 21058455)

  • 1. Neutron spectroscopy as a fuel ion ratio diagnostic: lessons from JET and prospects for ITER.
    Ericsson G; Conroy S; Gatu Johnson M; Andersson Sundén E; Cecconello M; Eriksson J; Hellesen C; Sangaroon S; Weiszflog M;
    Rev Sci Instrum; 2010 Oct; 81(10):10D324. PubMed ID: 21058455
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Prospects for measuring the fuel ion ratio in burning ITER plasmas using a DT neutron emission spectrometer.
    Hellesen C; Skiba M; Dzysiuk N; Weiszflog M; Hjalmarsson A; Ericsson G; Conroy S; Andersson-Sundén E; Eriksson J; Binda F
    Rev Sci Instrum; 2014 Nov; 85(11):11D825. PubMed ID: 25430238
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Neutron spectrometer for ITER using silicon detectors.
    Conroy SW; Weiszflog M; Andersson-Sunden E; Ericsson G; Gatu-Johnson M; Hellesen C; Ronchi E; Sjostrand H
    Rev Sci Instrum; 2008 Oct; 79(10):10E508. PubMed ID: 19044493
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Thin foil proton recoil spectrometer performance study for application in DT plasma measurements.
    Marcinkevicius B; Hjalmarsson A; Andersson Sundén E; Ericsson G
    Rev Sci Instrum; 2018 Oct; 89(10):10I107. PubMed ID: 30399976
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Neutron emission spectroscopy of D plasmas at JET with a compact liquid scintillating neutron spectrometer.
    Giacomelli L; Belli F; Binda F; Conroy SW; Eriksson J; Milocco A; Popovicev S; Syme DB;
    Rev Sci Instrum; 2018 Oct; 89(10):10I113. PubMed ID: 30399806
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Response function of single crystal synthetic diamond detectors to 1-4 MeV neutrons for spectroscopy of D plasmas.
    Rebai M; Giacomelli L; Milocco A; Nocente M; Rigamonti D; Tardocchi M; Camera F; Cazzaniga C; Chen ZJ; Du TF; Fan TS; Giaz A; Hu ZM; Marchi T; Peng XY; Gorini G;
    Rev Sci Instrum; 2016 Nov; 87(11):11D823. PubMed ID: 27910604
    [TBL] [Abstract][Full Text] [Related]  

  • 7. New developments in the diagnostics for the fusion products on JET in preparation for ITER (invited).
    Murari A; Angelone M; Bonheure G; Cecil E; Craciunescu T; Darrow D; Edlington T; Ericsson G; Gatu-Johnson M; Gorini G; Hellesen C; Kiptily V; Mlynar J; Perez von Thun C; Pillon M; Popovichev S; Syme B; Tardocchi M; Zoita VL;
    Rev Sci Instrum; 2010 Oct; 81(10):10E136. PubMed ID: 21061488
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Inferring neutron yields using indium activation samples for small fractions of tritium added to deuterium fuel in inertial confinement fusion (ICF) experiments.
    Mangan MA; Ruiz CL; Cooper GW; Chandler GA; Ampleford DJ
    Rev Sci Instrum; 2022 Oct; 93(10):103514. PubMed ID: 36319333
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Neutron spectroscopy results of JET high-performance plasmas and extrapolations to DT performance.
    Hellesen C; Andersson Sundén E; Conroy S; Ericsson G; Eriksson J; Gatu Johnson M; Weiszflog M;
    Rev Sci Instrum; 2010 Oct; 81(10):10D337. PubMed ID: 21058461
    [TBL] [Abstract][Full Text] [Related]  

  • 10. OVERVIEW OF NEUTRON MEASUREMENTS IN JET FUSION DEVICE.
    Batistoni P; Villari R; Obryk B; Packer LW; Stamatelatos IE; Popovichev S; Colangeli A; Colling B; Fonnesu N; Loreti S; Klix A; Klosowski M; Malik K; Naish J; Pillon M; Vasilopoulou T; De Felice P; Pimpinella M; Quintieri L;
    Radiat Prot Dosimetry; 2018 Aug; 180(1-4):102-108. PubMed ID: 29040768
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A neutron activation spectrometer and neutronic experimental platform for the National Ignition Facility (invited).
    Yeamans CB; Gharibyan N
    Rev Sci Instrum; 2016 Nov; 87(11):11D702. PubMed ID: 27910563
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Activation Inventories after Exposure to DD/DT Neutrons in Safety Analysis of Nuclear Fusion Installations.
    Stankunas G; Cufar A; Tidikas A; Batistoni P;
    Radiat Prot Dosimetry; 2018 Aug; 180(1-4):125-128. PubMed ID: 29186569
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fuel ion ratio measurements in reactor relevant neutral beam heated fusion plasmas.
    Hellesen C; Eriksson J; Conroy S; Ericsson G; Skiba M; Weiszflog M;
    Rev Sci Instrum; 2012 Oct; 83(10):10D916. PubMed ID: 23130799
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Indications of flow near maximum compression in layered deuterium-tritium implosions at the National Ignition Facility.
    Gatu Johnson M; Knauer JP; Cerjan CJ; Eckart MJ; Grim GP; Hartouni EP; Hatarik R; Kilkenny JD; Munro DH; Sayre DB; Spears BK; Bionta RM; Bond EJ; Caggiano JA; Callahan D; Casey DT; Döppner T; Frenje JA; Glebov VY; Hurricane O; Kritcher A; LePape S; Ma T; Mackinnon A; Meezan N; Patel P; Petrasso RD; Ralph JE; Springer PT; Yeamans CB
    Phys Rev E; 2016 Aug; 94(2-1):021202. PubMed ID: 27627237
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measurement and simulation of the response function of time of flight enhanced diagnostics neutron spectrometer for beam ion studies at EAST tokamak.
    Peng XY; Chen ZJ; Zhang X; Du TF; Hu ZM; Ge LJ; Zhang YM; Sun JQ; Gorini G; Nocente M; Tardocchi M; Hu LQ; Zhong GQ; Pu N; Lin SY; Wan BN; Li XQ; Zhang GH; Chen JX; Fan TS
    Rev Sci Instrum; 2016 Nov; 87(11):11D836. PubMed ID: 27910376
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Line integration effects on ion temperatures in tokamak plasmas measured with neutron emission spectroscopy.
    Ognissanto F; Gorini G; Tardocchi M; Albergante M; Ballabio L; Conroy S; Källne J
    Rev Sci Instrum; 2008 Oct; 79(10):10E511. PubMed ID: 19044495
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Neutron activation diagnostics at the National Ignition Facility (invited).
    Bleuel DL; Yeamans CB; Bernstein LA; Bionta RM; Caggiano JA; Casey DT; Cooper GW; Drury OB; Frenje JA; Hagmann CA; Hatarik R; Knauer JP; Johnson MG; Knittel KM; Leeper RJ; McNaney JM; Moran M; Ruiz CL; Schneider DH
    Rev Sci Instrum; 2012 Oct; 83(10):10D313. PubMed ID: 23126840
    [TBL] [Abstract][Full Text] [Related]  

  • 18. CALCULATIONS OF SHUTDOWN DOSE RATE FOR THE TPR SPECTROMETER OF THE HIGH-RESOLUTION NEUTRON SPECTROMETER FOR ITER.
    Wójcik-Gargula A; Tracz G; Scholz M
    Radiat Prot Dosimetry; 2018 Aug; 180(1-4):75-79. PubMed ID: 29244166
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Neutron emission spectroscopy of DT plasmas at enhanced energy resolution with diamond detectors.
    Giacomelli L; Nocente M; Rebai M; Rigamonti D; Milocco A; Tardocchi M; Chen ZJ; Du TF; Fan TS; Hu ZM; Peng XY; Hjalmarsson A; Gorini G;
    Rev Sci Instrum; 2016 Nov; 87(11):11D822. PubMed ID: 27910679
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A feasibility study of a deuterium-deuterium neutron generator-based boron neutron capture therapy system for treatment of brain tumors.
    Hsieh M; Liu Y; Mostafaei F; Poulson JM; Nie LH
    Med Phys; 2017 Feb; 44(2):637-643. PubMed ID: 28205309
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.