These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

84 related articles for article (PubMed ID: 21062228)

  • 21. Performance characteristics of five cardiac Troponin I assays.
    La'ulu SL; Roberts WL
    Clin Chim Acta; 2010 Aug; 411(15-16):1095-101. PubMed ID: 20398643
    [TBL] [Abstract][Full Text] [Related]  

  • 22. An interfering component in cardiac troponin I immunoassays-Its nature and inhibiting effect on the binding of antibodies against different epitopes.
    Eriksson S; Junikka M; Pettersson K
    Clin Biochem; 2004 Jun; 37(6):472-80. PubMed ID: 15183295
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Application of New Reference Procedure for ALP Measurement in the Clinical Laboratory.
    Han L; Wang J; Li Y; Zhang Q; Zheng S; Lin H; Huang X; Zhuang J
    Clin Lab; 2015; 61(5-6):445-52. PubMed ID: 26118174
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The lack of standardization of cardiac troponin I assay systems.
    Tate JR; Heathcote D; Rayfield J; Hickman PE
    Clin Chim Acta; 1999 Jun; 284(2):141-9. PubMed ID: 10451241
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Decision limit for troponin I on ADVIA:Centaur and evaluation of the analytical precision at low concentrations.
    Fortunato A; Giavarina D
    Clin Lab; 2003; 49(5-6):251-3. PubMed ID: 15285182
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The harmonization of cardiac troponin I measurement is independent of sample time collection but is dependent on the source of calibrator.
    Tate JR; Heathcote D; Koerbin G; Thean G; Andriske D; Bonar J; Gill J
    Clin Chim Acta; 2002 Oct; 324(1-2):13-23. PubMed ID: 12204420
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Measurement of cardiac troponin I in striated muscle using three experimental methods.
    Fredericks S; Bainbridge K; Murray JF; Collinson PO; Carter ND; Holt DW
    Ann Clin Biochem; 2003 May; 40(Pt 3):244-8. PubMed ID: 12803836
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Multicenter evaluation of analytical performance of the Liaison troponin I assay.
    Pagani F; Stefini F; Chapelle JP; Lefèvre G; Graïne H; Luthe H; Engelmayer J; Panteghini M
    Clin Biochem; 2004 Sep; 37(9):750-7. PubMed ID: 15329312
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A fluoro-microbead guiding chip for simple and quantifiable immunoassay of cardiac troponin I (cTnI).
    Song SY; Han YD; Kim K; Yang SS; Yoon HC
    Biosens Bioelectron; 2011 May; 26(9):3818-24. PubMed ID: 21439810
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Negative interference in cardiac troponin I immunoassays by circulating troponin autoantibodies.
    Eriksson S; Halenius H; Pulkki K; Hellman J; Pettersson K
    Clin Chem; 2005 May; 51(5):839-47. PubMed ID: 15718489
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Recombinant single chain cardiac troponin I-C polypeptides: superior calibration and control materials for cardiac troponin I immunoassays.
    Liu S; Zhang MY; Song Q; Ling M; Kadijevic L; Shi Q
    Clin Lab; 2001; 47(1-2):19-27. PubMed ID: 11214219
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Validation of a commercially available immunoassay for the measurement of bovine cardiac troponin I.
    Varga A; Schober KE; Walker WL; Lakritz J; Michael Rings D
    J Vet Intern Med; 2009; 23(2):359-65. PubMed ID: 19192157
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A comparison of cardiac troponin T and cardiac troponin I in patients with acute coronary syndromes.
    Wu AH
    Coron Artery Dis; 1999; 10(2):69-74. PubMed ID: 10219511
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Isoelectric point determination of cardiac troponin I forms present in plasma from patients with myocardial infarction.
    Peronnet E; Becquart L; Martinez J; Charrier JP; Jolivet-Reynaud C
    Clin Chim Acta; 2007 Feb; 377(1-2):243-7. PubMed ID: 17113062
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Cardiac Troponin I carryover by very high patient samples still causes false-positive results on the Beckman Coulter AccuTnI + 3.
    Wilgen U; Pretorius CJ; Gould MJ; Ungerer JP
    Ann Clin Biochem; 2016 Jan; 53(Pt 1):177-9. PubMed ID: 26345181
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Antigenic definition of cardiac troponin I.
    Larue C; Ferrieres G; Laprade M; Calzolari C; Granier C
    Clin Chem Lab Med; 1998 Jun; 36(6):361-5. PubMed ID: 9711422
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Protein array for assist diagnosis of acute myocardial infarction.
    Guo H; Zhang J; Yang D; Xiao P; He N
    Colloids Surf B Biointerfaces; 2005 Feb; 40(3-4):195-8. PubMed ID: 15708513
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Evaluation of the analytical performance of the advanced method for cardiac troponin I for the AxSYM platform: comparison with the old method and the Access system.
    Storti S; Prontera C; Parri MS; Iervasi A; Vittorini S; Emdin M; Zucchelli GC; Longombardo G; Migliorini P; Clerico A
    Clin Chem Lab Med; 2006; 44(8):1022-9. PubMed ID: 16879072
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Longitudinal studies of cardiac troponin-I concentrations in serum from male Sprague Dawley rats: baseline reference ranges and effects of handling and placebo dosing on biological variability.
    Schultze AE; Carpenter KH; Wians FH; Agee SJ; Minyard J; Lu QA; Todd J; Konrad RJ
    Toxicol Pathol; 2009 Oct; 37(6):754-60. PubMed ID: 19700656
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Evaluation of two modified cardiac troponin I enzyme immunoassays.
    Haug C; Bachem MG; Woehrle H; Hetzel M; Gruenert A
    Clin Chem Lab Med; 2002 Aug; 40(8):837-9. PubMed ID: 12392315
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.